Coal chemical wastewater: this industry cannot be found in the standards, and there is no salt discharge outlet either.

Multi-industry projects across China (modern coal chemical, coal-to-olefins, coa
Pilot to full-scale engineering (120 m³/h to tens of thousands of m³/d; phenol-a

Water in the Coal Chemical Industry: No Standard Covers This Sector, and There Is No Outlet for the Salt

In the current GB 31571, "petrochemical industry" is defined as using petroleum fractions and natural gas as raw materials. Coal-to-olefins burns coal, so textually it is not covered. Only the second draft for comments of 2026 年 5 月 includes it, and for the first time sets three values for total salt content — 8000, 3000, and 6000 — and these three values are constrained by three different downstream factors respectively.

Industrial Water Treatment Technology · Coal Chemical Plant-wide Water Management · Standard Attribution and Salt Outlet | 2026-10-28

Coal chemical wastewater has two characteristics not found elsewhere. First, for a long time it had no matching industry emission standard, and enterprises actually implemented comprehensive standards, local standards, or more commonly — EIA approvals. Second, its endpoint is not water but salt: water can be reused, but salt cannot, and can only become crystallized salt or hazardous waste. This article breaks down four accounts: which standard this industry falls under, who constrains each of the three total salt content values, why phenol-ammonia recovery must be sequenced and cannot be in the same tank, and how reuse rate and total salt content undermine each other arithmetically.

I. This industry cannot be found in the standards

Chapter 3 of GB 31571—2015 defines "petrochemical industry" as: the industry that uses petroleum fractions, natural gas, etc. as raw materials to produce organic chemicals, synthetic resins, synthetic fibers, synthetic rubber, etc. There is no coal in this sentence. The second draft for comments of 2026 年 5 月 changed the definition to "using petroleum fractions, natural gas, etc. as raw materials and organic chemicals produced therefrom as raw materials", and clearly stated in Section 5.2: "coal chemical industry production facilities identical to the production facilities covered by this standard" are included in the scope of control.

That is to say, from 2015 年 7 月 until this draft for comments is implemented, a coal-to-olefins project cannot find its own line in the national standard system. When the 2017 年 standard was fully implemented, local government interpretation articles stated this very plainly: the standard clearly defines the petrochemical industry as using petroleum fractions, natural gas, etc. as raw materials, meaning that a national standard for pollutant emissions applicable to the modern coal chemical industry, with coal gasification as the lead and syngas as the main intermediate product, has still not been issued.

Without an industry standard, what is actually implemented? Two things step in: first, the GB 8978 comprehensive emission standard; second, the EIA approval. Look at an approval issued by the Ministry of Ecology and Environment of 2024 年 1 月 for a 80 万-ton coal-to-olefins project in Xinjiang: the water-related requirement is not "meet a certain standard", but "all types of wastewater, after treatment by the wastewater treatment system, shall be reused and not discharged". This sentence is harder than any concentration limit — it requires zero discharge volume, while standards only govern concentration.

This is the first layer of particularity in coal chemical water management: its constraint is often not in the tables of a standard, but in a sentence of an approval. When preparing a scheme, even flipping to the end of the GB 8978 tables will not turn up the three words "not discharged".

Criterion one: To determine which standard an industry implements, do not look only at the industry name; look at how the definition in Chapter 3 of the standard is written. The definition limits the raw materials; if the raw materials do not match, the entire standard does not apply. This is the same category as GB 21900 in the 10-24 fluorine-containing draft excluding electroless plating by using "utilizing electrolytic methods" — applicability is written in the definition, not in the title.

II. Three total salt content values, each constrained by whom

Among the three items newly added in the second draft for comments, total salt content has the greatest impact on the coal chemical industry. It gives three values, and the derivation paths of these three values are completely different — this point is stated very clearly in the compilation notes and is worth copying down item by item.

Table 1 Three-tier limits for total salt content, and what constrains each value
Discharge DestinationLimit mg/LWhat Constrains This ValueDerivation Given in the Compilation Notes
Direct discharge into surface water such as rivers and lakes8000Achievability and cost of end-of-pipe desalination at the plantDirect discharge limits for the pesticide and food industries are both 10000; this industry is tightened further; desalination cost is 60~80 元 per ton of water
Indirect discharge into centralized wastewater treatment facilities such as industrial parks6000Salt tolerance limit of the downstream biological systemWithout acclimated halotolerant bacteria, the influent total salt content must not exceed 6000 to ensure biological stability
Indirect discharge into municipal wastewater treatment plants3000Downstream pipe network and Reclaimed Water ReuseCalculated at a minimum dilution factor of 2; 3000 corresponds to total dissolved solids of 1500 under GB/T 31962
Discharge to the sea and estuaries: the direct discharge limit of 8000 does not apply; this limit applies only to discharge into surface water such as rivers and lakes

Looking at the three rows separately, 3000 is derived by a "division": the standard for the downstream pipe network is 1500, your water is diluted into it by a factor of 2, so you can only discharge 3000. 6000 is determined by a "biological experiment": Activated Sludge loses activity once salinity exceeds a certain point, so it is capped at 6000. 8000 is determined by "cross-industry comparison + cost": other industries discharge directly at 10000, and you cannot be looser than them, but tightening further would make desalination costs unsustainable.

Behind the three numbers are three completely different disciplines, so they are not interconvertible. This explains why, for the same enterprise, simply changing the discharge destination causes its Total Salt Content allowance to drop from 8000 to 3000—it is not that the standard has become stricter, but that the exam paper has been changed.

Table 2 Maximum Allowable Salt Concentration for Various Treatment Processes (Tongji University data, cited from the Preparation Notes)
Treatment StageMaximum Allowable Salt ConcentrationConverted to mg/L
Activated Sludge Process0.8%~0.9%8000~9000
Biological Filter1.0%~4.0%10000~40000
Contact Oxidation Process2.5%~3.5%25000~35000
Sludge Treatment0.5%~1.0%5000~10000

There is one easily overlooked point in this table: the biological stage can withstand 8000 to 9000, but the lower limit for the sludge stage is 5000. Therefore, the figure of 6000 is not determined by the most salt-tolerant stage, but by the least salt-tolerant link in the chain. In the same plant, the aeration tank may be fine, but the dewatering room is the first to have problems—salt enters the sludge, and the settling and dewatering performance of the sludge changes accordingly. This kind of situation, where "the weak link is not in the tank you are watching," has the same structure as the moisture content being back-calculated from the downstream interface in the 10-20 sludge dewatering draft.

III. Reuse Rate and Total Salt Content Undermine Each Other Arithmetically

Salt does not degrade, nor does it leave with water vapor (what evaporation carries away is water). Therefore, how much salt a plant discharges depends only on how much is brought in with the influent; and the salt concentration in the discharge equals the salt input divided by the discharge volume. The smaller the discharge volume—that is, the higher the reuse rate—the higher the concentration. This is an identity and requires no process details.

Take a medium-scale project: water intake 1000 m³/h, make-up water total dissolved solids 500 mg/L. The salt brought into the system per hour is 500 kg. Assuming all salt leaves via the discharge (no crystallization desalination), with discharge volume Q, then:

Discharge total salt content (mg/L) = 500 000 ÷ Q(m³/h)

Table 3 Reuse Rate and Total Salt Content of Discharge (self-calculated, water intake 1000 m³/h, make-up water 500 mg/L)
Water Reuse RateDischarge Volume m³/hTotal Salt Content of Discharge mg/LDirect Discharge 8000Industrial Park 6000Urban 3000
90%1005000CompliantCompliantExceeded
91.7%83.36000CompliantExactly at limitExceeded
93.75%62.58000Exactly at limitExceededExceeded
95%5010000Exceeded 25%Exceeded 67%Exceeded by 2.3 times
97%3016700Exceeded by 1.1 timesExceeded by 1.8 timesExceeded by 4.6 times
Schematic of closed-loop circulation and salt accumulation in a coal chemical water system
Figure 1 Water circulates in the closed loop, and salt accumulates in the closed loop. Each step up in reuse rate makes the discharged stream one notch saltier—evaporation carries away only water.

This table lays one thing bare: the two requirements in the water-saving enterprise assessment—"reuse rate not lower than 97%"—and in the discharge standard—"total salt content not higher than 8000"—cannot both be satisfied without crystallization desalination.97% corresponds to 16700, more than twice the limit. To satisfy both, there are only two paths: lower the reuse rate below 93.75%, or install desalination equipment to turn the salt into solid.

The first path is not feasible for many projects, because the water intake quota is capped from above (see Section 8): the water intake index is fixed as a hard limit per ton of product, and any extra fresh water withdrawal would exceed the quota. Thus only the second path remains — which is also why zero liquid discharge in the coal chemical industry is not an environmental preference, but something forced by arithmetic.

Criterion 2: For any combination of "high reuse rate + total-quantity-type index," do a division first before discussing the solution. Salt, Total Dissolved Solids, chloride, fluoride (calculated as ions), and boron — these non-degradable indices all obey the same identity: concentration = input mass ÷ discharge volume. The reuse rate is a subtraction from the denominator; once it is reduced to a certain point, any end-of-pipe process is merely wiping the denominator's bottom.

IV. How dirty this water is, and how many streams it is divided into

The wastewater from coal chemical production is not a single stream. By generation stage, it can be divided into at least four categories: coal gasification wastewater (phenol-ammonia wastewater), production sewage from methanol and olefin units, circulating cooling water blowdown, and chemical water station and boiler blowdown. The truly difficult one is the first stream, which accounts for a small share of the plant's total water volume but the bulk of the pollution load.

Table 4 Magnitude of Coal Gasification Wastewater (varies greatly with different gasifiers and coal types)
SourceCOD mg/LTotal Phenols mg/LAmmonia Nitrogen mg/LOther
Lurgi Fixed-Bed Pressurized Gasification (Coal-to-SNG)20000~550005000~140004500~13000Heterocycles such as pyridine and quinoline, and monocyclic/polycyclic aromatic hydrocarbons, with high biological toxicity
Case of a Gasification Plant (Before Retrofit)72300114005040pH 5~10.5, containing tar, coal ash, and fatty acids
Same Case, After Phenol-Ammonia Recovery5770120 (volatile phenols)195Sulfides 120, suitable for biological treatment

These figures first give a sense of proportion: phenol-ammonia wastewater contains over ten grams of phenols per liter, while the volatile phenol limit of GB 8978 Class I standard is 0.5 mg/L. In other words, the phenol concentration of this stream is more than twenty thousand times the discharge limit. This magnitude difference determines one thing—it cannot be handled by "treatment" alone, but only by "recovery." Recovery refers to chemical unit operations (stripping, extraction, distillation), while treatment refers to environmental unit operations (biological treatment, oxidation). The former makes money; the latter costs money.

The purpose of splitting the streams is to send each stream where it belongs. In the approval for that coal-to-olefins project in Xinjiang, the wastewater treatment units are directly divided into two sets by product line: methanol wastewater goes through "pretreatment + primary softening + two-stage A/O + secondary clarifier + secondary softening + V-type filter," while olefin wastewater goes through "oil separation + air flotation + A/O + MBR"; the reuse unit is further divided into a "clean wastewater series" and a "methanol wastewater series," with the produced water returning to the circulating water station, and the concentrated brine going to "precision pretreatment + membrane separation and concentration + MVR falling film evaporation + fractional crystallization," with sodium chloride and sodium sulfate as by-products.

Note that the end of this chain is not "up-to-standard discharge" but "by-product salt." This is where coal chemical differs most from refining and thermal power: the salt from refining and thermal power can be disposed of via desulfurization towers or sea outfalls, whereas coal chemical plants are inland, so the salt can only exit through crystallizers.

V. Phenol-Ammonia Recovery: Three Processes, Three Orderings

Phenol-ammonia recovery is the only link in coal chemical water management that "becomes more profitable the more it is done," and it is also where process routes diverge most. The divergence is not in the equipment but in the sequence.

To remove phenol, the phenol must first be driven from water into an organic solvent, and the prerequisite for extraction is that the phenol is in molecular form (undissociated). The pKa of phenol is about 10; the lower the pH, the higher the proportion in molecular form and the greater the extraction distribution coefficient. So to remove phenol, one should acidify first.

To remove ammonia, NH₄⁺ must be converted to NH₃ before it can be stripped out, and this step requires alkali addition. So to remove ammonia, the pH must go above 10.

The two objectives require opposite pH values. This is why the three mainstream routes differ from one another: they are in fact ordering the same contradiction.

Table 5 Ranking Differences of Three Phenol-Ammonia Recovery Routes
ProcessSequenceEffluent Total PhenolsEffluent CODCost
Lurgi PhenosolvanAcidification first → Extraction for phenol removal → Stripping for acid and ammonia removal——Long flow, many column equipment, high investment
SEDIN (Deacidification-Dephenolization-Deammoniation)Deacidification first → Extraction for phenol removal → DeammoniationGreater than 10005000~6000High deacidification and deammoniation efficiency, but high effluent phenols, difficult for downstream biological treatment
SCUT Single-Column (Deacidification-Deammoniation-Dephenolization)Single-column pressurized simultaneous deacidification and deammoniation to pH less than 7 → MIBK extraction → Three-column solvent recoveryApprox. 350Approx. 2000Three grades of steam, high energy consumption; crude ammonia side stream carries phenols 100~200

The cleverness of the third route lies in this: instead of reconciling that pH contradiction, it compresses the contradiction into a single column and solves it simultaneously—under pressure, one column simultaneously removes acid gas and ammonia, and the water leaving the column bottom has already dropped to below pH 7, which is exactly right for subsequent extraction without further acidification. The cost is that once the pH is low, ammonia removal must be done under pressure, raising the steam grade. For a treatment capacity of 100 t/h, the three rectification columns require 1.0, 2.5, and 0.5 MPaG of steam respectively, with heat loads of 10.17, 1.97, and 2.68 MW, totaling 14.82 MW.

To convert: 14.82 MW ÷ 100 t/h = 0.533 MJ/kg, which means about 0.53 GJ per ton of water, and based on a latent heat of steam of 2.1 MJ/kg, about 250 kg of steam. This figure determines the cost structure of phenol-ammonia recovery—it is an evaporation unit, not a chemical dosing unit.

Schematic of two-phase countercurrent flow in an extraction column
Figure 2 Two-phase countercurrent flow in the extraction column: the aqueous phase flows downward, while the solvent phase carries phenol upward. The distribution coefficient determines how much phenol can be removed at the same column height, and pH determines the distribution coefficient.

The distribution coefficient column is the most telling. Diisopropyl ether (DIPE) has a high distribution coefficient for monohydric phenols such as phenol, but only 0.18 for pyrogallol and only 1.03 for hydroquinone—polyphenols are essentially immovable. Methyl isobutyl ketone (MIBK) has values of 5.0 and 9.9 for these two polyphenols, respectively, which are 28 times and 9.6 times those of DIPE.

Therefore, one extraction column is not enough. The engineering approach is two-stage series operation: the first stage uses DIPE to recover monohydric phenols (it has low water solubility, 0.8%, a boiling point of 68.5 ℃, and is inexpensive to recover), and the second stage uses MIBK to recover polyphenols (it has a water solubility of 1.9%, a boiling point of 117–118 ℃, and is expensive to recover). The problem is not that the wrong solvent was selected; it is that one solvent cannot handle two types of phenols.

VI. The Full Account of an Engineering Case

For a phenol-ammonia recovery unit of 120 m³/h at a certain gasification plant, the accounts before and after revamping are relatively complete and can be compared directly.

Table 6 Influent/Effluent and Removal Rates Before and After Retrofit (120 m³/h)
ParameterInfluent mg/LEffluent mg/LRemoval Rate
COD72300577092%
Total Phenols11400120 (Volatile Phenols)94%
Ammonia Nitrogen504019596%
SulfideApprox. 2400 (back-calculated from 95%)12095%

Four changes were made in the retrofit: the two towers were converted into a single tower with "stripping deacidification + side-stream deammonification," with NaOH added inside the tower to decompose fixed ammonium salts and prevent ammonium bicarbonate crystallization from plugging the pipes; the single-stage single-tower extraction was changed to a two-stage extraction in series with dual towers, using DIPE for monohydric phenols and MIBK for polyhydric phenols; a circulation pump and internal reflux were added to the UASB, raising the upflow velocity from 1.3 m/h to 3.3 m/h; and the A/O process was changed to multi-stage, multi-point influent. When the MIBK dosage reaches above 12 mg/L, the removal rates of COD and total phenols no longer increase significantly.

The key is to look at the outlet location: volatile phenol 120 mg/L is 240 times the GB 8978 Class I standard 0.5, COD 5770 is 58 times 100, and ammonia nitrogen 195 is 13 times 15. This is not a case of poor performance; it is the normal outlet指标 of the phenol-ammonia recovery stage—its task is to reduce toxicity to a level where microorganisms can survive, not to meet discharge standards. What truly brings these three numbers down is the subsequent UASB plus multistage A/O; during the UASB stable period, the volumetric loading rate is 6.2 kg COD/(m³·d), the reflux ratio is 150%, and the upflow velocity is 3~5 m/h.

Regarding cost, the original text lists both four expenditure items and two recovery items:

Table 7 Operating cost breakdown, CNY/m³
ItemAmount
Utilities such as steam, circulating water, and electricity43.96
Extractant and wastewater treatment chemicals5.63
Personnel and sludge disposal2.33
Subtotal of expenditures51.92
Ammonia recovery benefit−13.93
Crude phenol recovery benefit−2.99
Comprehensive operating cost given in the original text22.2

A discrepancy that does not add up: Subtracting the first six rows of the table above, 51.92 − 16.92 = 25.00 元/m³, whereas the comprehensive cost given in the original text is 22.2 元/m³, a difference of 2.8 元 (about 11%). The original text does not list the source of this 2.8 元; it may be related to steam being converted at a different unit price, or to the pricing basis for recovered products. When citing this figure, it is advisable to cite the two figures 51.92 and 16.92, which can be verified independently, rather than the conclusive figure 22.2.

Utilities account for 85%, which matches perfectly with the 0.53 GJ per ton of water calculated earlier: the cost of phenol-ammonia recovery is the steam cost; savings should come from the heat exchange network and the grade of the columns, not from chemicals. This also explains why the three process routes compete on "how many columns, how many steam grades" rather than "which extractant is cheaper."

VII. The Salt Outlet: Salt Fractionation or Mixed Salt

At the end of the water treatment train, the remaining issue is salt. A salt fractionation project of a coal chemical enterprise in Inner Mongolia provides the most complete set of public data currently available: 2022 年 with an investment of nearly 1.5 亿 yuan, successfully commissioned in a single start-up at the end of 2023 年, adopting "multi-stage Nanofiltration / NF membrane + Advanced Oxidation / AOP + crystallization evaporation."

Table 8 Output and conversion of a certain quality-based salt production project (from 2022 年 commissioning to the time of public reporting)
ItemPublicly reported valueConversion
Cumulative treated concentrated brine219.61 万 m³—
Sodium chloride output51665 t23.5 kg/m³
Sodium sulfate output2845 t1.30 kg/m³
Total salt output54510 t24.8 kg/m³, i.e. approximately 2.5%
Salt-to-sulfate ratio18.2 : 1Sodium chloride accounts for 94.8%

These three conversion figures are very telling. First, the salt content of the concentrated brine is about 2.5%, still far from saturation, so membrane concentration must be carried out before entering the crystallizer; otherwise what is evaporated is water, not salt. Second, the salt-to-sulfate ratio of 18 to 1—the sodium sulfate in this stream is only one-eighteenth of the sodium chloride, yet for this small fraction a separate freeze crystallization unit must be installed, because sodium sulfate and sodium chloride co-crystallize at high temperatures, and precipitating together yields mixed salt. Third, each cubic meter of concentrated brine carries out 24.8 kg of salt; multiplied by the plant's total water volume, this figure gives the amount of solid waste that must find an outlet every day.

Schematic of the three outlets for salt
Figure 3 Salt has only three outlets: discharged with water (must meet the total salt content limit), sold as crystallized salt (requires a buyer), or temporarily stored as mixed salt (must be managed as solid waste or hazardous waste). The third route has no valve, only a warehouse.

For the mixed salt route, there is a saying in the industry: "You can afford to treat the water, but not to bury the salt." Reports indicate that the hazardous waste disposal cost of waste salt accounts for about half of the total operation and maintenance cost of a ZLD system; another project description is more specific — while achieving ZLD, it still generates about 2 t of waste mixed salt per hour, temporarily managed as hazardous solid waste. ZLD means the water does not leave, not that the salt does not exist.

The difficulty of salt separation is not in evaporation either. Sodium sulfate is abundant in natural mineral deposits and low in price; combined with transportation costs and customer acceptance, its sales channel is poor, and many projects give it away for free. Therefore, the value of "fractional crystallization" lies largely not in how much money is made from selling sodium sulfate, but in moving mixed salt off the hazardous waste list. This is also why some enterprises first file for "point-to-point" comprehensive utilization of mixed salt — filing is a compliance action, crystallization is a process action, and both must be done simultaneously.

Regarding purity, publicly available data show: the rejection rate of sulfate by NF salt separation can reach over 90%; the purity of crystallized salt from thermal salt separation is 90%~95%, rising to over 95% after salt washing; for projects using fractional crystallization, sodium chloride can reach Grade I refined industrial salt per GB/T 5462, and sodium sulfate can reach Class I first-grade per GB/T 6009; for dedicated waste salt treatment units, the purity of sodium chloride and Glauber's salt can reach over 99.3%, with organics below 50 mg/kg salt.

Criterion 3: When evaluating a ZLD scheme, do not ask "what is the water reuse rate"; ask three questions: Is the salt separated, to whom is the separated salt sold, and under what classification is the unsold portion temporarily stored? If these three questions cannot be answered, a water reuse rate of 98% is only an intermediate indicator. This is in the same family as the 10-17 thermal power article's "ZLD must ask where the pollutants ultimately end up in which solid waste," but here in coal chemical it is more thorough — its solid waste is not a byproduct, but one of the main products.

VIII. Water Intake: The Same Indicator, Two Assessment Values

The water intake indicator for coal chemical is capped per ton of product. In the attachment to the MIIT Water Efficiency Leader application report, assessment values for various modern coal chemical products are given per GB/T 37759—2019; while in the technical indicator self-assessment table published by a province in 2025 年, the same products are given a different set of figures.

Table 9 Water Intake per Unit Product of Modern Coal Chemical Industry, Comparison of Two Sets of Assessment Values, m³/t
ProductMIIT Water Efficiency Leader AnnexSelf-Assessment Form of a Certain Province 2025 年Difference
Coal-to-Olefins≤24≤16Tightened by 1/3
Coal-to-Methanol≤11≤11Same
Coal-to-Ethylene Glycol (coal-based)≤20≤20Same
Syngas-to-Ethylene Glycol≤12≤12Same
Coal-to-Liquid, Direct Liquefaction≤6.5≤6.2Tightened by 5%
Coal-to-Liquid, Indirect Liquefaction≤10.75≤7Tightened by 35%
Coal-to-Synthetic Natural Gas≤8(m³/kNm³)≤7Tightened by 13%

Among the seven products, four have identical values and three differ, with the differences for Coal-to-Olefins and Coal-to-Liquid Indirect Liquefaction both exceeding 30%. Such differences are usually not clerical errors but differences in boundaries: whether water intake includes once-through cooling water, whether the denominator counts intermediate products, and whether off-site water supply and park-shared portions are included. The GB/T 18916 series, while specifying quotas, also states the "water intake and water intake supply scope" — that section is the criterion.

There is another detail about coal-to-olefins in the water intake quota system: it does not have a separate part, and falls under GB/T 18916.13 "Norm of water intake—Part 13: Ethylene and propylene". In other words, for a coal-based olefins plant, the water intake quota is looked up in the ethylene and propylene volume. This is structurally the same as the standard attribution issue in Section 1—the coal chemical industry has no place of its own in many standards systems and can only borrow the name of the neighboring seat.

IX. Field Points: Five Directly Usable Ones

Condense the above sections into something executable:

  • Determine the destination first, then the process. The total salt content allowance is determined by the discharge destination (8000/6000/3000), and the terminal processes of the three routes are completely different: direct discharge requires desalination, discharge to an industrial park requires controlling 6000 and ensuring downstream biological salt tolerance, and discharge to a municipal system requires controlling 3000, and new enterprises have been explicitly prohibited from discharging into it.
  • Calculate the reuse rate together with the water price and salt price. For every step up in the reuse rate, the discharge volume drops by one level and the total salt content doubles by one level. The curve in Table 3 is the design boundary; do not list "reuse rate 97%" and "total salt content compliance" as two parallel objectives in the scheme.
  • Phenol-ammonia recovery is assessed by "recovery", not by "compliance". Effluent phenol 120 mg/L is the norm; its KPI is the steam consumption per ton of water and the recovery rates of crude phenol and liquid ammonia, not the discharge concentration.
  • Configure the extractant according to the type of phenol. Use DIPE for monohydric phenols and MIBK for polyhydric phenols, in a two-stage series. Do not expect to solve polyhydric phenols by increasing the single-stage phase ratio—for something with a distribution coefficient of 0.18, adding solvent will not move it.
  • The salt problem lies with the buyer, not the crystallizer. The main benefit of fractional crystallization is moving mixed salt out of hazardous waste; sodium sulfate has a poor market and is often given away free, so count it as zero revenue or negative revenue in the economic evaluation.
Table 10 Quick Reference of Key Parameters
StageParameterValue
Phenol-ammonia recoveryExtraction pH/temperature/phase ratio/number of stagespH 5~10, 40~60 ℃, phase ratio 1:8~1:2, 4~6 stages (patent example range pH 3~11, 30~85 ℃, 1:10~10:1, 3~8 stages)
Single-column deacidification and deammoniationColumn bottom pHReduce to below 7 before extraction
Solvent recoverySteam pressure of the three columns1.0/2.5/0.5 MPaG, heat load 10.17/1.97/2.68 MW (100 t/h)
UASBVolumetric load/upflow velocity/reflux ratio6.2 kgCOD/(m³·d)/3.3 m/h (original 1.3)/150%
Salt separationNanofiltration sulfate rejectionAbove 90%
CrystallizationCrystallized salt purity/after salt washing90%~95%/above 95%
Total salt contentDirect discharge/industrial park/municipal8000/6000/3000 mg/L

X. Conclusion

There are three difficulties with water in the coal chemical industry, and none of them are in the reaction tank.

First, its standard position is borrowed. The definition in GB 31571 limits raw materials to petroleum fractions and natural gas, and coal-to-olefins is textually not included; only the second draft for comments added this line, and explicitly stated that new enterprises shall implement it from the date of publication, while existing enterprises shall implement it two years later. Before that, the real constraint on enterprises came from the phrase "reuse without discharge" in the environmental impact assessment approval.

Second, its water saving and compliance undermine each other arithmetically. Salt does not degrade, and concentration equals input divided by discharge volume. A reuse rate of 97% corresponds to a total salt content of 16700 mg/L in the discharged water, which is more than twice the direct discharge limit. For both indicators to hold simultaneously, desalination is the only option—this is the origin of zero liquid discharge in the coal chemical industry; it is not an environmental preference, it is division.

Third, its endpoint is solid waste rather than water. Each cubic meter of concentrated brine carries out about 24.8 kg of salt; after salt separation, sodium chloride accounts for 94.8% and sodium sulfate for only 5.2%, and the latter has poor market demand. Mixed salt is temporarily stored as hazardous waste, and disposal costs account for about half of zero liquid discharge operation and maintenance costs. Therefore, the accurate meaning of the four words "zero liquid discharge" in the coal chemical industry is: water does not leave the plant, salt does not leave the plant, and the accounts must balance.

As for phenol-ammonia recovery, it is the only link in the entire process that turns pollution load into a product, and also the only link worth optimizing for "saving one kilogram of steam." The differences among the three routes appear to be a dispute over sequence, but in essence they are different arrangements of the same pH contradiction—this criterion is more useful than memorizing any single process route.

References

  1. "Emission Standard of Pollutants for Petroleum Chemistry Industry" (GB 31571—2015) published draft, Chapter 1 Scope of Application, Chapter 3 Terms and Definitions (Petroleum Chemistry Industry: using petroleum fractions, natural gas, etc. as raw materials). https://www.mee.gov.cn/ywgz/fgbz/bz/bzwb/dqhjbh/dqgdwrywrwpfbz/201505/W020150506394632230539.pdf
  2. "Emission Standard of Water Pollutants for Petroleum Chemistry Industry (Second Draft for Comments)" compilation notes, 5.1 Main revision points, 5.2 Scope of application, 5.3 Terms and definitions, 5.4 Pollutant control items, 5.5.1 Total salt content, 5.8 Benchmark discharge volume. https://www.mee.gov.cn/xxgk2018/xxgk/xxgk06/202605/W020260520597620446016.pdf
  3. Ibid., 5.5.1: Total salt content direct discharge 8000 mg/L, discharged to urban sewage treatment plants 3000 mg/L, discharged to other centralized sewage treatment facilities 6000 mg/L; direct discharge limits do not apply to discharge to the sea and estuaries; desalination cost per ton of water 60~80 元; approximately 300 enterprises and 30 industrial parks need to add desalination facilities.
  4. Ibid., 5.5.1 citing Tongji University data: Activated Sludge process maximum allowable salt concentration 0.8%~0.9%, Biological Aerated Filter 1.0%~4.0%, contact oxidation 2.5%~3.5%, sludge treatment 0.5%~1.0%; without acclimated halotolerant bacteria, influent total salt content must not exceed 6000 mg/L for stable operation.
  5. Ibid., 5.5.1: When discharged to urban sewage treatment plants, calculated at minimum dilution factor of 2 times, 3000 mg/L can meet the requirements of 1500 mg/L in GB/T 31962; 2024 年 during enforcement inspections, 11 enterprises monitored for total salt content had concentrations ranging from 535~3240 mg/L.
  6. "Water Quality Standard for Sewage Discharged into Urban Sewers" (GB/T 31962—2015): Total dissolved solids Class A/B/C 1500/2000/2000 mg/L; compilation notes indicate that salt content above 3500 mg/L is corrosive to sewers.
  7. Report on public consultation for "Emission Standard of Water Pollutants for Petroleum Chemistry Industry (Second Draft for Comments)" (2026 年 5 月, feedback deadline 2026 年 6 月 20 日): three new items added — total salt content, perfluorooctanoic acid, and zebrafish embryo acute toxicity; scope expanded to include coal chemical industry production facilities. https://www.cenews.com.cn/news.html?aid=1786181
  8. "Reply on Environmental Impact Report of Xinjiang Dongming Plastics Co., Ltd. Annual 80 万 tons Coal-to-Olefins Project" (Ministry of Ecology and Environment, 2024 年 1 月): methanol wastewater "pretreatment + primary softening + two-stage A/O + secondary sedimentation tank + secondary softening + V-type filter", olefin wastewater "oil separation + air flotation + A/O + MBR", reuse "high-density sedimentation tank + Ultrafiltration + primary Reverse Osmosis + high-efficiency Reverse Osmosis of concentrate", concentrated brine "precision pretreatment + membrane separation concentration + MVR falling film evaporation + fractional crystallization", all types of wastewater treated and reused without discharge. https://www.mee.gov.cn/xxgk2018/xxgk/xxgk11/202401/t20240125_1064668.html
  9. Local government website reprint of standard interpretation (2017 年 7 月): The standard defines petroleum chemistry industry as using petroleum fractions, natural gas, etc. as raw materials, meaning that a national standard for pollutant emissions applicable to the modern coal chemical industry with coal gasification as the leading process has still not been issued. http://www.hekou.gov.cn/art/2017/7/10/art_69471_7235204.html
  10. Enhanced process for phenol-ammonia separation and recovery system in coal gasification wastewater (2023): Lurgi fixed-bed pressurized gasification wastewater contains phenol 5000~14000 mg/L, NH₄⁺-N 4500~13000 mg/L, COD 20000~55000 mg/L; SEDIN process effluent phenol greater than 1000, COD 5000~6000; South China University of Technology single-column process effluent total phenol approximately 350, COD approximately 2000; three-column steam 1.0/2.5/0.5 MPaG, 100 t/h corresponding heat load 10.17/1.97/2.68 MW; crude ammonia side stream contains phenol 100~200 mg/L. https://www.dowater.com/jishu/2023-01-06/3358723.html
  11. Coal gasification wastewater treatment engineering case study and new process research (II) — Modification of phenol-ammonia extraction recovery process: influent total phenol 11400, COD 72300, ammonia nitrogen approximately 5040 mg/L; after modification volatile phenol 120 (94%), ammonia nitrogen 195 (96%), sulfide 120 (95%), COD 5770 (92%); DIPE water solubility 0.8%, boiling point 68.5 ℃, MIBK solubility 1.9%, boiling point 117~118 ℃; pyrogallol partition coefficient 0.18 (DIPE) and 5.0 (MIBK), hydroquinone 1.03 and 9.9; UASB upflow velocity 1.3→3.3 m/h, volumetric loading 6.2 kgCOD/(m³·d), reflux ratio 150%; operating cost utilities 43.96, chemicals 5.63, personnel and sludge 2.33 元/m³, ammonia recovery 13.93, crude phenol 2.99 元/m³.
  12. Treatment and recovery methods for phenol-containing coal gasification wastewater: wastewater pH 5~10.5, COD 15000~30000 mg/L, total ammonia 6000~9000 mg/L; MIBK extraction pH 5~10, temperature 40~60 ℃, phase ratio 1:8~1:2, 4~6 stages. https://m.dowater.com/Tech/2018-12-15/860172.html
  13. Clean production treatment of high-concentration wastewater from crushed coal pressurized gasification via phenol-ammonia recovery: after deacidification and deammoniation and extraction dephenolization, wastewater generally has COD below 3000, total phenol below 300, ammonia nitrogen below 300 mg/L. https://m.dowater.com/Tech/2018-04-16/696471.html
  14. China Industry Economy Information Network "Full-chain efforts in high-salinity wastewater treatment in the chemical industry": one enterprise's quality-based salt production project 2022 年 invested nearly 1.5 亿 yuan, "multi-stage Nanofiltration membrane + Advanced Oxidation + crystallization evaporation", successful first startup at the end of 2023 年; cumulative treatment of concentrated brine 219.61 万 m³, sodium chloride 51665 t, sodium sulfate 2845 t; waste salt hazardous waste disposal cost accounts for about half of the entire system O&M cost, "can afford to treat water, but cannot afford to bury salt"; a certain waste salt treatment facility produces sodium chloride and mirabilite with purity exceeding 99.3%, organic matter below 50 mg/kg salt. https://www.cinic.org.cn/hy/hg/1645059.html
  15. High-salinity industrial wastewater precipitation salt separation zero discharge system: water resource reuse rate approximately 98%; sodium chloride crystallized salt meets GB/T 5462—2015 refined industrial salt first-grade product, sodium sulfate meets GB/T 6009—2014 Class I first-grade product; sodium sulfate, due to abundant natural mineral resources, transportation costs and customer acceptance, is mostly given away free of charge. https://www.dowater.com/Tech/2019-06-20/1005289.html
  16. Method for extracting sodium sulfate from saline wastewater: a certain coal chemical project achieves zero discharge while producing approximately 2 t waste mixed salt per hour (tentatively designated as hazardous solid waste); Nanofiltration sulfate rejection rate can reach above 90%; Nanofiltration permeate is concentrated by RO and Electrodialysis to TDS not less than 150000 mg/L before thermal crystallization. https://m.dowater.com/Tech/2018-02-08/653739.html
  17. Comprehensive salt separation technology for high-salinity wastewater in coal chemical industry: falling film + forced circulation evaporation concentration to sodium chloride saturation, single-effect evaporation stage boiling point 120~125 ℃, cooling to 20~40 ℃ to crystallize sodium nitrate; operating off the co-saturation curve, crystallized salt purity 90%~95%, after salt washing above 95%. https://m.dowater.com/jishu/2021-02-18/1587822.html
  18. MIIT Water Efficiency Leader application report attachment (Modern Coal Chemical Industry technical assessment requirements, GB/T 37759—2019): coal-to-methanol ≤11, coal-to-ethylene glycol ≤20 (syngas-based ≤12), coal-to-oil direct liquefaction ≤6.5/indirect liquefaction ≤10.75, coal-to-synthetic natural gas ≤8, coal-to-olefins ≤24 m³/t; reuse rate ≥97%, indirect cooling water circulation rate ≥98%, comprehensive water loss rate ≤2%. https://www.gov.cn/zhengce/zhengceku/2020-01/03/5466317/files/e061fc504d9d4245b53c2ea69fa6c8a7.pdf
  19. Fujian Province 2025 年 Modern Coal Chemical Industry technical indicators self-assessment form: coal-to-methanol ≤11, coal-to-ethylene glycol ≤20 (syngas-based ≤12), coal-to-oil direct liquefaction ≤6.2/indirect liquefaction ≤7, coal-to-synthetic natural gas ≤7, coal-to-olefins ≤16 m³/t; notes list the corresponding relationship of water intake quotas in GB/T 18916.33/34/35/36/39 and Part 13 (ethylene and propylene).
  20. "Integrated Wastewater Discharge Standard" (GB 8978—1996) Table 4: first-level standard volatile phenol 0.5, Chemical Oxygen Demand 100, ammonia nitrogen 15, sulfide 1.0 mg/L (used to measure the relative position of phenol-ammonia recovery effluent).

The standard clauses, limits, and derivation processes in this article are all cited from the Ministry of Ecology and Environment published drafts and compilation notes; case data come from public engineering reports, EIA approvals, and publicly available enterprise information; scale, investment, and costs are reported values and have not been verified on site. The converted values in Table 3 and Table 8 and the steam conversion in Section 5 are self-calculated based on public data; the calculation process has been listed in the main text and can be reviewed item by item. The three total salt content limits are based on the second draft for comments; the officially published text may be adjusted.