After the Odor Is Driven into the Air: 0.33 kg/h, 15 Seconds, and a Countdown
The previous article on sulfur-containing wastewater left one sentence: after adding alkali, the odor was gone, but not a single milligram of sulfur was reduced—it had merely changed hosts. This article takes over at the air end—0.33 kg/h is the permitted emission rate for a 15-meter exhaust stack, 15 seconds is the lower limit for the residence time in the biological stage, and the three numbers—airflow rate, residence time, and outlet concentration—move in opposite directions.
I. The accounts from the previous article have shifted into the air: three reporting bases, not three indicators
The article on sulfur-containing wastewater calculated that when sulfur is driven from water into air, the water column immediately looks better, while the air column goes from zero to a positive number. How the air column is recorded depends on three things: where the gas is sampled, how the sampled quantity is converted, and what method is used for measurement. GB 14554 addresses these three things separately, so the same odor control unit must simultaneously face three reporting bases.
| Control Item | Class I | Class II New/Expanded/Reconstructed | Class II Existing | Class III New/Expanded/Reconstructed |
|---|---|---|---|---|
| Ammonia | 1.0 | 1.5 | 2.0 | 4.0 |
| Trimethylamine | 0.05 | 0.08 | 0.15 | 0.45 |
| Hydrogen Sulfide | 0.03 | 0.06 | 0.10 | 0.32 |
| Methyl Mercaptan | 0.004 | 0.007 | 0.010 | 0.020 |
| Dimethyl Sulfide | 0.03 | 0.07 | 0.15 | 0.55 |
| Dimethyl Disulfide | 0.03 | 0.06 | 0.13 | 0.42 |
| Carbon Disulfide | 2.0 | 3.0 | 5.0 | 8.0 |
| Styrene | 3.0 | 5.0 | 7.0 | 14 |
| Odor Concentration | 10 | 20 | 30 | 60 |
Table 1 sets the limits for fugitive emissions, with sampling points at the plant boundary; Table 2 sets the limits for organized emissions, with sampling points at the exhaust stack. The dimensions of the two tables are completely different: Table 1 is concentration, while Table 2 is emission quantity. This is not arbitrary formatting, because fugitive emissions have no "air volume" to speak of—you do not know which crack the odor comes out of or at what flow rate, so it can only be regulated by "the concentration smelled at the boundary"; whereas organized emissions have a pipe, and the amount of gas in the pipe is known, so the limit is written as "how many kilograms are allowed to escape per hour."
The third metric is odor concentration. It is neither a concentration nor an emission quantity, but a dilution ratio. The definition in GB/T 14675—93 is: the sample is continuously diluted with odor-free clean air until it reaches the olfactory threshold of the panelist, and that dilution ratio is the odor concentration. It is dimensionless, and its detection limit is 10—meaning that at the lower limit this metric has only two possible answers: "less than 10" and "equal to 10"; there is no 3 and no 7.
II. Scope 1: The stack table contains only kg/h, no mg/m³
Table 2 of GB 14554 contains nine items in total. Eight of them give the correspondence between "stack height—emission quantity (kg/h)", and the ninth item, odor concentration, gives a dimensionless value that varies with height. From beginning to end there is not a single mg/m³ concentration column. This is often overlooked in review meetings, because almost all deodorization schemes, equipment samples, and acceptance reports state "outlet hydrogen sulfide ≤ x mg/m³". That x is an internal control value set by the owner or design institute itself; it is not in the standard.
| Control Item | 15 m | 25 m | 40 m | 60 m |
|---|---|---|---|---|
| Hydrogen Sulfide | 0.33 | 0.90 | 2.3 | 5.2 |
| Methyl Mercaptan | 0.04 | 0.12 | 0.31 | 0.69 |
| Ammonia | 4.9 | 14 | 35 | 75 |
| Odor Concentration | 2000 | 6000 | 20000 | 60000 |
The absence of a concentration column means that only after the concentration is multiplied by the air flow rate does it become the quantity subject to assessment. Used in reverse, this is the most practical division in this project: divide 0.33 kg/h by the air flow rate to obtain the maximum allowable outlet concentration for this system.
| Exhaust Stack Airflow | Allowable Outlet Concentration | Equivalent Removal Efficiency at Inlet 100 mg/m³ |
|---|---|---|
| 3 600 m³/h | 91.7 mg/m³ | 8.3% is sufficient |
| 10 000 m³/h | 33.0 mg/m³ | 67.0% |
| 20 000 m³/h | 16.5 mg/m³ | 83.5% |
| 50 000 m³/h | 6.6 mg/m³ | 93.4% |
| 69 000 m³/h | 4.8 mg/m³ | 95.2% |
| 100 000 m³/h | 3.3 mg/m³ | 96.7% |
The rightmost column of this table is worth pausing on. At an airflow of 6.9 万 m³/h, the rate limit is equivalent to "inlet 100 mg/m³, outlet 4.8 mg/m³", that is, a removal efficiency of 95.2%; while Article 3.2.3 of CJJ/T 243 specifies exactly that "the treatment efficiency of the odor treatment device for indicators such as hydrogen sulfide and odor concentration should not be less than 95%". The two figures come from completely different derivation directions—one is the emission rate divided by the airflow, the other is the efficiency directly stipulated by the standard—yet they mesh precisely at the order of 6.9 万 m³/h.
Conversely, a small system with 3600 m³/h must export 91.7 mg/m³ to hit the threshold, requiring only a removal rate of 8.3%. In other words, the same 0.33 kg/h is virtually meaningless for small systems but a real threshold for large systems. This explains a common misalignment in engineering practice: at small sites, no matter how small the odor control equipment is selected, it still "meets the standard," leading owners to believe odor control is not difficult; by the time it comes to plant-level projects of 20 万 m³/h, the same experience immediately fails to hold.
There is another, more fundamental constraint that is often skipped: Article 5.2 of GB 14554 requires that both the "emission amount" and the "odor concentration" of odorous pollutants discharged through stacks must be lower than or equal to the standard values. Two quantities are listed side by side here—one is kg/h, and the other is the dimensionless odor concentration 2000. The former can be calculated by multiplying concentration by air volume; the latter cannot be calculated and can only be measured. Therefore, during acceptance of an odor control system, the H₂S column can rely on calculation, while the odor concentration column can only rely on smelling.
III. Criterion Two: Plant boundary 0.06 and odor concentration 20 are judged by the human nose
The plant boundary column concerns fugitive emissions, and the sampling method is specified in HJ 905—2017: sampling points are set on the downwind axis of the prevailing wind direction along the perimeter and within the standard deviation range of wind direction variation, generally 3 points, at about 1.5 m above ground, with 270 degrees of free space around them; monitoring is not suitable in rain or snow because pollutants will be absorbed and the data will not be representative.
The frequency is set as "collect once every 2 小时, collect 4 times in total, and take the maximum measured value." The key phrase is "maximum measured value"—not the average, not the median, but the worst of the four. An odor control system designed according to the average but judged according to the maximum at acceptance leaves the gap in between as a hidden risk. This frequency is not a soft requirement: in an administrative reconsideration case in Huzhou (Huzheng Fu [2023] No. 120), a third-party institution was found to have falsified monitoring data because it failed to sample once every 2 小时 for a total of 4 samples; the institution faced a fine of 5 万 to 20 万 yuan, and the directly responsible person was fined separately. Sampling frequency is written in technical specifications, but it is judged on the basis of data authenticity.
The odor concentration item is even more special. HJ 1262—2022 divides the method into two sets: for ambient air and fugitive emission monitoring points, 6 panelists and 18 3 L gas bags are used in 6 groups, with each dilution ratio repeated three times; for stationary pollution source exhaust gas, no fewer than 4 panelists and 12 gas bags are used in 4 groups, repeated twice, and then a t-test with 95% confidence interval is used to determine whether there is a significant difference between the two results; if there is a difference, one more measurement is made. The statistical methods are also different: the criterion for fugitive emissions is the panel average correct-answer rate M value; if M is greater than 0.58, dilution continues; for stationary sources, the logarithmic average of individual odor thresholds is taken.
Odor concentration is the only indicator that can neither be retained for re-testing nor calibrated with standard samples. HJ 1262 stipulates that samples must be stored in the dark and measured within 24 小时; beyond this window, the data become invalid; panelists are human, and the same bag of gas will differ between different laboratories and different batches. Therefore, there is a paradox in engineering practice: the indicator closest to complaints is precisely the least reproducible one. What residents smell is odor concentration, while the only things you can write with confidence in a report are hydrogen sulfide and ammonia.
As for how strict the plant boundary 20 actually is, it can be sensed through the detection limit: the method detection limit is 10, and the plant boundary standard 20 means "dilute twice and it can no longer be smelled." Ambient background around 10 is common. The margin in this column is much smaller than the numbers suggest.
IV. Criterion Three: The efficiency of 95% depends on how dirty the inlet is
The third criterion is removal rate, and among the three sets of criteria it is the one most easily treated as "equipment performance." Article 3.2.3 of CJJ/T 243 states clearly: treatment efficiency should not be less than 95%; when the plant boundary or environmentally sensitive areas cannot meet standards, the odor source collection rate (area) should be increased or the odor treatment equipment efficiency should be improved. This sentence places the two paths side by side, which in fact says: efficiency is not the only variable; collection is also one.
The problem with removal rate is that it has no absolute quantity. Inlet 100 mg/m³, removal rate 95%, outlet 5 mg/m³; inlet 20 mg/m³, removal rate 95%, outlet 1 mg/m³; inlet 400 mg/m³, removal rate 95%, outlet 20 mg/m³—already exceeding the rate limit of the system at 6.9 万 m³/h (4.8 mg/m³). The same 95% falls into three completely different compliance states.
What is more troublesome is the reverse situation: when the inlet is very clean, 95% is an easily obtainable number, and the outlet 1 mg/m³ looks good, but it cannot indicate how the unit will perform under high load. Therefore, in the acceptance report, the line "removal rate 95%" must be written together with "inlet concentration"; otherwise it cannot even withstand a single division.
V. Air Volume: Four Calculation Methods for the Same Tank, Differing by 4 Times
The collected air volume is the denominator of the entire system—it determines the packing volume, fan power, pipe diameter, emission rate, and also the retention time. Yet it is precisely the number with the most calculation methods and the loosest basis in the specifications.
Article 3.1.3 of CJJ/T 243 provides four methods: for the suction well of the influent pump or the grit chamber, calculate based on unit water surface area 10 m³/(m²·h), and the space ventilation rate of 1 to 2 air changes per hour may be added; for the primary clarifier or thickening tank, etc., based on 3 m³/(m²·h), similarly 1 to 2 air changes per hour may be added; for aeration treatment structures, based on 110% of the aeration volume; for semi-enclosed equipment, based on the two methods of 8 air changes per hour inside the cover and an extraction air velocity of 0.6 m/s at the opening, take the smaller value.
The clause explanation also leaves a sentence: when the aeration tank is covered for odor removal, considering leakage from the covered equipment, the leakage amount is calculated as 10% of the air volume; for structures that personnel need to enter, the extraction air volume should preferably be based on not less than 8 air changes per hour, for those frequently entered and with higher requirements, 12 air changes per hour, and for non-entry spaces such as sludge storage silos, 2 air changes per hour. This sentence and the four methods in the main text are two sets of logic: the main text is based on water surface area, while the explanation is based on spatial volume.
| Method | Formula | Result |
|---|---|---|
| Code 3.1.3 Clause 2 (water surface index + air exchange) | 300×3+450×(1~2) | 1 350~1 800 m³/h |
| Common engineering practice, air exchange 8 times/h | 450×8 | 3 600 m³/h |
| Common engineering practice, air exchange 12 times/h | 450×12 | 5 400 m³/h |
| Aeration tank based on aeration rate 110% (aeration intensity 3 m³/(m²·h)) | 900×1.1 | 990 m³/h |
For the same tank, the minimum is 990 and the maximum is 5400, a difference of 5.5 times. If the media volume is back-calculated based on a 15 second retention time, 1 350 m³/h corresponds to 5.6 m³, and 5 400 m³/h corresponds to 22.5 m³—four times the media, four times the blowers, four times the electricity bill, all determined by "which method you choose".
The standard itself also acknowledges that this is difficult to determine. Article 3.1.3 states: if the gas collection volume is too small, below the odor diffusion rate or failing to achieve a reasonable flow regime inside the collection cover, gas will escape; if the gas collection volume is too large, investment and operating costs will increase, and if it exceeds the odor diffusion rate by too much, it may fail to meet the load requirements of the treatment equipment, leading to a decline in treatment efficiency. The last half-sentence is self-evident: if the air volume is too large, treatment efficiency will drop. The reason is in the next section.
The negative pressure value likewise has three sets of figures. In manufacturers' technical manuals, some specify maintaining −5 to −10 Pa inside the cover, some specify −10 to −50 Pa, and reverse-hung membrane solutions specify 50 to 200 Pa. The physical meanings of these three ranges differ: the first two are the magnitude required for "emission prevention," while the last is the magnitude required for "membrane structure formation." Mixing them up will lead to completely opposite conclusions during commissioning—if adjusted according to −5 Pa, the seal will fail as soon as it ages; if adjusted according to −200 Pa, the fan will be permanently oversized.
VI. An Inverse Relationship: As Air Volume Rises, Residence Time and Removal Rate Fall Together
When the packing volume is fixed, air volume and residence time have a strict inverse relationship:
When the air volume doubles, the residence time is halved. And the effect of halving the residence time on outlet concentration is not linear. The Chengdu Institute of Biology, Chinese Academy of Sciences, provided a clean comparison in a biological trickling filter pilot test: with multi-faceted hollow sphere packing, inlet gas at 0 to 500 ppm, and an empty bed residence time of 31.8 s, the hydrogen sulfide removal rate was 98.25% and ammonia 88.55%, with a maximum removal load of 84.57 g H₂S/(m³·h); when the residence time was shortened to 25.4 s, the removal rates dropped to 67.21% and 81.36%.
| Empty Bed Residence Time | Hydrogen Sulfide Removal Efficiency | Outlet Concentration | Relative to Previous Row |
|---|---|---|---|
| 31.8 s | 98.25% | 1.75 ppm | — |
| 25.4 s | 67.21% | 32.79 ppm | Outlet ×18.7 |
This is the most important table in this article. Removal efficiency drops from 98.25% to 67.21%, which looks like merely "a drop of thirty-one points," but the outlet concentration is amplified 18.7 times—because removal efficiency is the complement of "how much is left"; the closer to 100%, the smaller the complement, and a small change in the complement means a large change in the outlet. Wherever removal efficiency is used as an acceptance indicator, this nonlinearity is at work; it is just that no one has calculated it out.
VII. The hard line of 15 seconds: only two of the three parameters can be fixed
CJJ/T 243 Article 4.4.11 gives four requirements for biological filtration and biological trickling filtration: the empty bed residence time should not be less than 15 s, and in severe cold and cold regions it should be extended according to the inlet gas temperature; the empty bed gas velocity should not be greater than 300 m/h; the height of a single packing layer should not be greater than 3 m; the unit packing load should be determined according to the odor concentration and removal requirements, and the hydrogen sulfide load should not be higher than 5 g/(m³·h).
The first two are actually not two parameters. Empty bed gas velocity multiplied by residence time is the packing layer height:
That is to say, when designed according to the upper limit gas velocity and lower limit residence time in the standard, the resulting packing layer height is exactly 1.25 m, which falls within "a single layer should not be greater than 3 m". Only two of the three numbers are free—if you raise the gas velocity to 600 m/h and still want to maintain 15 s, the packing layer must be 2.5 m; if you want to use 1 m packing, the gas velocity can only be reduced to 240 m/h.Whenever you see a document listing "residence time, gas velocity, packing height" side by side, do the multiplication first; the extra number is often artificially fixed during equipment selection.
| Parameter | Specified Value | Converted Meaning |
|---|---|---|
| Empty Tower Retention Time | Should not be less than 15 s | Jointly determines the packing layer height with gas velocity |
| Empty Tower Gas Velocity | Should not be greater than 300 m/h | i.e., surface loading ≤300 m³/(m²·h) |
| Single Packing Layer Height | Should not be greater than 3 m | 15 s × 300 m/h = 1.25 m, with margin |
| Hydrogen Sulfide Loading | Should not be higher than 5 g/(m³·h) | At 15 s, corresponds to inlet of approximately 20.8 mg/m³ |
The fourth item is worth calculating once more. Loading is "how many grams are removed per cubic meter of packing per hour," and its relationship with the inlet concentration is:
Substituting 5 g/(m³·h) and 15 s, we obtain 20.8 mg/m³. This is a very small number. However, the measured hydrogen sulfide at the inlet of the deodorization unit in the pretreatment area of the Bailonggang Wastewater Treatment Plant ranges from 100 to 400 mg/m³, methyl mercaptan from 10 to 30 mg/m³, and odor concentration from 6000 to 12000—which is 5 to 20 times higher than this "specification upper limit."
VIII. 5 and 667 of Loading Rate: Design Values Are Not Capacity Upper Limits
When public data are arranged together, a gap emerges that looks like an error.
| Source | Loading | Operating Condition |
|---|---|---|
| CJJ/T 243 Article 4.4.11 | 5.0 | Design value (should not exceed) |
| Bailonggang biological stage (back-calculated from inlet 100 mg/m³) | 13.0 | Retention 25 s, removal 90% |
| PU + brown fiber biological filter ECmax | 24.1 | EBRT 47 s, removal 86.1% |
| Bailonggang biological stage (back-calculated from inlet 400 mg/m³) | 51.8 | Retention 25 s, removal 90% |
| BTF pilot test (multi-faceted hollow spheres) | 84.6 | EBRT 31.8 s |
| Double-layer trickling filter (patented) | 120 | GRT 19 s, removal >90% |
| Thiobacillus thiooxidans trickling tower (Activated Carbon media) | 333.2 | Retention 23 s, removal 94.4% |
| Same as above, kinetic maximum loading | 666.7 | Saturation constant 0.87 g/m³ |
5 and 667 differ by a factor of 133. This gap cannot be explained as "the specification being conservative," because the specification does not say this is a capacity ceiling; it says "should not exceed" — the tone of a design value. Its true meaning must be sought in the clause explanation: long-term operation of the biological stage accumulates elemental sulfur and biofilm, causing pressure drop to rise and localized channeling; the closer the loading is to the capacity ceiling, the sooner these two things occur. The high loadings in the literature are short-term peaks judged by compliance with standards; the low loading in the specification is the value for "no media replacement for years."
The Bailonggang example shows that the real engineering solution is not to suppress the load to 5, but rather staged treatment. The odor concentration in the pretreatment zone is too high for the biological stage to handle alone, so a three-stage series is adopted: biological trickling filter (1 m bamboo charcoal media, circulating spray pH 3 to 4, empty bed residence time 25 s, removal above 90%) → chemical scrubbing (1 m plastic ball media, residence time 25 s, spray pH 9 to 11, ORP 350 to 450 mV, maintained with sodium hypochlorite) → photolysis (residence time 3 to 5 s) → 15 m stack emission.
| Stage | Packing and Retention | Control Conditions | Function |
|---|---|---|---|
| Biotrickling | 1 m bamboo charcoal, 25 s | Spray pH 3~4 | Removes more than 90% of hydrogen sulfide |
| Chemical Scrubbing | 1 m plastic balls, 25 s | pH 9~11, ORP 350~450 mV | Removes the remaining hydrogen sulfide |
| Photolysis | —, 3~5 s | — | Organics and safeguard |
Note that the pH of these two stages goes in opposite directions: the biological stage at 3 to 4, and the chemical stage at 9 to 11. This is not a setup error. After hydrogen sulfide is oxidized by sulfur-oxidizing bacteria, sulfuric acid is produced, and the filter bed acidifies on its own; during operation, it is normal for pH to drop below 2—studies have reported that after long-term operation of biological filters, sulfate accumulates in the packing to 10.8 mg/g and pH drops below 2.1. Since it will inevitably become acidic, pH is controlled at 3 to 4 to stabilize it; while the chemical stage must absorb hydrogen sulfide and allow sodium hypochlorite to oxidize, which must be carried out under alkaline conditions, otherwise the absorption liquid quickly becomes ineffective. The two stages require opposite pH values, which can only be solved by series connection, not by combining them in one tank—this is structurally the same conclusion as in the article on sulfur- and cyanide-containing wastewater, but that time the third substance was generated in the same tank, whereas this time each of the two stages requires an extreme.
IX. The Chemistry of Air: 8.34 kg Available Chlorine, and 53 元 One Kilogram of Sulfur
The chemical dosing account for chemical scrubbing can be calculated directly by electron conservation, without consulting samples. Sulfur in hydrogen sulfide is at −2 valence, oxidized to sulfate at +6 valence, an eight-electron process; available chlorine (calculated as Cl₂) gains two electrons per mole, therefore:
Substituting these two coefficients into a system of 1 万 m³/h with an inlet of 200 mg/m³: hydrogen sulfide introduced per hour 2.0 kg, requiring available chlorine 16.7 kg, converted to 10% sodium hypochlorite solution 167 kg/h. At a solution price of 640 元/t, the chemical cost is 107 元/h. Meanwhile, the fan electricity cost of the same system can be calculated separately: air volume 1 万 m³/h, total system resistance 1500 Pa, fan efficiency 0.7, shaft power 5.95 kW, at 0.6 元/kWh it is 3.57 元/h.
| Item | Calculation Formula | Result |
|---|---|---|
| Hydrogen Sulfide Input | 10 000×200÷10⁶ | 2.0 kg/h |
| Available Chlorine Demand | 2.0×8.34 | 16.7 kg/h |
| 10% Sodium Hypochlorite Solution | 16.7÷10% | 167 kg/h |
| Chemical Cost | 0.167 t/h×640 元/t | 107 元/h |
| Fan Electricity Cost | 5.95 kW×0.6 元/kWh | 3.57 元/h |
The thirty-fold gap is exactly the economic reason why the biological process has become the main process (accounting for about 78%) while the chemical process only serves as a polishing stage. The operating cost of the biological process consists only of fan power consumption plus a small amount of spray water, equivalent to about 0.36 元/thousand cubic meters per unit gas volume; the chemical cost of the chemical process rises linearly with the inlet concentration, and the higher the concentration, the more unsustainable it becomes. This also explains why high-concentration zones must use biological treatment before chemical treatment: the biological stage removes 90% of the sulfur, and the chemical stage only needs to handle the remaining ten percent, so the chemical dosage drops to one tenth.
By the way, a note on the reliability of the cost data. In publicly available sources, the figures for deodorization operating costs range from "0.8 元/thousand cubic meters" to "0.5 元/cubic meter." If the latter were valid, a system of 20 万 m³/h would cost 10 万 yuan per hour in operating costs, or 8 亿 per year—which is clearly invalid. Back-calculating from fan power, 0.3 to 0.5 元/thousand cubic meters is a reasonable range; writing "thousand cubic meters" as "cubic meter" inflates the figure by a factor of 1000.
10. The Money Account: 300 元/(m³/h), and a Quotation That Doesn't Add Up
Calculating the investment amount is a routine practice in this project: divide the total investment by the air volume to obtain a unit price that allows horizontal comparison. The deodorization project at the Si Ji Qing Wastewater Treatment Plant in Huai'an, Jiangsu, is a complete public case: the retrofit portion (6.5 万 m³/d) has a design air volume of 5 万 m³/h and an investment of 1382.04 万 yuan; the expansion portion (4 万 m³/d) has a design air volume of 1.9 万 m³/h and an investment of 685.55 万 yuan; the total is 2067.59 万 yuan and 6.9 万 m³/h, including structure capping and sealing, collection pipes and valves, collection fans, biological filters, and the automatic control system.
The unit prices back-calculated from the two sub-projects are 276 元/(m³/h) and 361 元/(m³/h), which combine to approximately 300 元/(m³/h). This figure includes civil works capping—and capping often accounts for about thirty percent of the entire system. Therefore, the equipment-scope unit price should be higher than 300, but not by an order of magnitude.
Compare this with a set of quotation data for 2026 年 deodorization boxes: 5000 to 1 万 m³/h is quoted at 8 to 15 万 yuan, 1 万 to 2 万 at 15 to 30 万 yuan, 2 万 to 5 万 at 30 to 70 万 yuan, and above 5 万 at 70 to 150 万 yuan. Back-calculating from the midpoint of each tier, the unit price falls within 14 to 16 元/(m³/h), and decreases slightly as air volume increases—which is consistent with economies of scale. But the same document also states a "converted unit price of 1500 to 3000 元/(m³/h)," which differs from its own tiered table by a factor of 50 to 375.
The account for another technical route is even more worth examining. A paper mill's wastewater station sends collected odorous gas to a boiler for incineration, compared with a biological filter option: the biological filter requires an investment of over 1200 万 yuan and operating costs of 332.31 万 yuan/year (including electricity and chemicals); sending the gas to the boiler for incineration requires an investment of 800 万 yuan and operating costs of only 147 万 yuan/year for the fan and dehumidification unit electricity. Investment is saved by 400 万 yuan and annual operation by 184.69 万 yuan, with a differential payback period of 2.17 年.
The value of this case lies not in its conclusion, but in the fact that it treats "whether an existing furnace is available" as the first variable in selection. For enterprises with a boiler, surplus incineration capacity, and short distances, the marginal cost of deodorization is just the induced draft fan and piping; for those without a furnace, the biological method is the most economical. Under the same standard and for the same type of odorous gas, the answer to selection depends on what the plant already has.
11. Seven Points from the Field: What Can Be Measured, What Can Be Adjusted, What Will Break
| What to Monitor | Normal Range | What an Abnormality Indicates |
|---|---|---|
| Negative pressure inside the cover | −5 to −50 Pa (per design value) | Drops to around 0 = aging seal strips, access door not closed |
| Pressure drop across packing layer | Stable, rising slowly with operation | Abnormal rise = biofilm too thick or elemental sulfur clogging |
| Spray liquid pH | Biological stage 3 to 4; chemical stage 9 to 11 | Biological stage drops below 2 = acidification out of control |
| Circulating liquid ORP | Chemical stage 350 to 450 mV | Below 300 = insufficient sodium hypochlorite, absorption failure |
| Actual residence time | ≥15 s (back-calculated from air flow rate) | Below 12 s = air flow rate turned up or packing collapse |
| Inlet gas temperature | 15 to 35 ℃ | Below 10 ℃, efficiency drops noticeably; chemical stage must compensate |
| Odor concentration at plant boundary | ≤20 (maximum of four measurements) | If exceeding standard, check the collection surface first, not replace packing first |
Among the seven, the first and fifth are the most easily overlooked. When negative pressure drops, the removal rate of the entire equipment set does not change at all—the efficiency calculated from inlet and outlet sampling remains above 95%—but the plant boundary cannot be brought down, because what is treated is "the gas that is collected"; the portion not collected does not participate in the calculation. This is why Article 3.2.3 of CJJ/T 243 places "increasing the odor source collection rate (area)" before "improving treatment efficiency." As for the fifth, when the fan frequency converter raises the frequency, the air flow rate goes up and the residence time comes down, and the outlet concentration amplifies nonlinearly by a factor of 18.7, while what is observed on site is merely "the fan is louder."
There is also a hard operational fact: packing media must be replaced. For the activated carbon adsorption unit, the specified empty bed residence time is 2 to 5 s, the particle size is 3 to 4 mm, the packing density is 350 to 550 kg/m³, and the bed thickness is 0.3 to 0.5 m; the replacement timing is judged by pressure drop. Biological packing media have no unified replacement cycle and must be judged by three criteria together: pressure drop, removal rate, and visual inspection for compaction. Promises such as "packing media life 5 年" in manufacturer brochures actually depend on whether the inlet gas contains dust and oil and whether spraying is continuous—once spraying stops, the packing media dries out, compacts, and channels, and the residence time immediately exists in name only.
XII. Compress This Article into Five Sentences
- The stack table only has kg/h. Only when 0.33 is divided by the air volume do you get the allowable outlet concentration; at 6.9 万 m³/h, it is equivalent to 4.8 mg/m³, exactly 95.2% of the inlet 100 mg/m³—that 95% in the specification is not arbitrary; it is derived by dividing by the rate.
- The plant boundary 0.06 and odor concentration 20 are judged by the human nose. Four samples taking the maximum, completion of measurement within 24 小时, 6 people and 18 bags—this method cannot retain samples and cannot be reproduced, so it can prove "no odor is smelled," but it is hard to prove "no odor is ever smelled."
- Air volume is both the denominator and the numerator. For the same tank, four calculation methods differ by 5.5 times; when the air volume doubles, the residence time is halved, the outlet concentration increases nonlinearly, and the emission rate rises at the same time. The single action of extracting more air worsens three things.
- 15 seconds, 300 m/h, and 1.25 m are the same constraint. Of the three numbers, only two are free; multiplying by 5 g/(m³·h) gives the inlet upper limit 20.8 mg/m³—while the measured value in the pretreatment area is 100 to 400, so staged treatment or pretreatment must be added.
- 5 and 667 are not contradictory; they are two ways of speaking. The specification says "should not be higher than," which is a design value; the literature reports equipment capability. Mixing them will cause errors in both directions at once: buying too much packing media, or prematurely maxing out the fan.
References
- GB 14554—93 "Emission Standards for Odor Pollutants", Table 1 factory boundary standard values (nine items including odor concentration), Table 2 emission standard values (kg/h given by stack height), Articles 5.1 to 5.3 implementation requirements. Full text of the standard is publicly available from the Ministry of Ecology and Environment.
- CJJ/T 243—2016 "Technical Specification for Odor Treatment of Municipal Wastewater Treatment Plants", Article 3.1.3 (four algorithms for odor air volume), Article 3.2.3 (treatment efficiency should not be less than 95%; if the factory boundary does not meet standards, collection rate should be increased or efficiency improved), Articles 4.3.1 to 4.3.11 (negative pressure collection, duct material, fan requirements), Article 4.4.2 (scrubber empty tower velocity 0.6 to 1.5 m/s, packing retention 1 to 3 s, liquid-gas ratio not less than 1 L/m³).
- CJJ/T 243—2016 Article 4.4.11: for biological filtration and biotrickling filtration, the empty bed residence time should not be less than 15 s, the empty bed gas velocity should not be greater than 300 m/h, the height of a single packing layer should not be greater than 3 m, and the hydrogen sulfide load should not be higher than 5 g/(m³·h).
- CJJ/T 243—2016 Articles 4.4.19 and 4.4.21: activated carbon adsorption unit empty bed residence time 2 to 5 s, particle size 3 to 4 mm, porosity 50% to 65%, specific surface area should not be less than 900 m²/g, packing density 350 to 550 kg/m³, layer thickness 0.3 to 0.5 m.
- CJJ/T 243—2016 Article 3.1.3 of the clause explanations: monitoring data from covered structures may be lower compared with open structures; the leakage rate of covered aeration tanks is calculated at 10% of the air volume; ventilation for spaces entered by personnel not less than 8 times/h, frequently entered 12 times/h, sludge storage silos 2 times/h.
- HJ 905—2017 "Technical Specifications for Environmental Monitoring of Odor Pollution", Section 4.2 (downwind axis point layout at the factory boundary, generally 3 points, monitoring should be avoided in rain or snow), Section 4.4 (for fugitive emissions, sample once every 2 h for a total of 4 times and take the maximum; for organized emissions, not less than 3 times and take the maximum).
- HJ 1262—2022 "Ambient Air and Waste Gas — Determination of Odor — Triangle Odor Bag Method": fugitive emissions 6 panelists 18 bags, stationary sources not less than 4 panelists 12 bags, M value 0.58 termination criterion, determination within 24 h of sampling, blank test standing for about 30 h.
- GB/T 14675—93 "Air Quality — Determination of Odor — Triangle Odor Bag Method": odor concentration is defined as the dilution ratio, individual odor thresholds are taken as logarithmic means, and after arithmetic averaging by the panel, raised to the power of 10.
- "Discussion on Design Issues of Odor Removal Engineering for Underground Wastewater Treatment Plants", citing the engineering values of empty bed residence time and empty bed gas velocity for the biological stage in CJJ/T 243—2016, as well as the practice of shortening the residence time to about 12 s in the medium concentration zone.
- "Calculation Methods for Odor Air Volume of Each Unit of Odor Removal Devices in Municipal Wastewater Treatment Plants", a unit-by-unit calculation method based on unit water surface area indicators (collection well and grit chamber 10, primary sedimentation tank and anoxic tank 3 m³/(m²·h)), air change rates (dewatering machine room 6 to 12 times/h), and infiltration air volume coefficients 5% to 10%.
- Shanghai Bailonggang Wastewater Treatment Plant odor removal project case: pretreatment area inlet hydrogen sulfide 100 to 400 mg/m³, methyl mercaptan 10 to 30 mg/m³, odor concentration 6000 to 12000; three-stage series connection of biotrickling filtration (1 m bamboo charcoal, pH 3 to 4, retention 25 s) + chemical scrubbing (1 m plastic balls, pH 9 to 11, ORP 350 to 450 mV, retention 25 s) + photolysis (3 to 5 s), 15 m stack.
- Huan Chenchen et al., "Pilot Study on Simultaneous Removal of Hydrogen Sulfide and Ammonia by Biotrickling Reactor", Journal of Cleaner Production; at EBRT 31.8 s, hydrogen sulfide removal rate 98.25%, ammonia 88.55%, maximum removal load 84.57 and 38.77 g/(m³·h); at EBRT 25.4 s, decreased to 67.21% and 81.36%; on-site biogas residue composting odor removal rate 91.34%. Achievement report of the Chengdu Institute of Biology, Chinese Academy of Sciences.
- "Removal Characteristics of Hydrogen Sulfide in Gas by Immobilized Thiobacillus thiooxidans", Chinese Journal of Environmental Engineering, 2018, 12(11): 3109-3115; activated carbon packing, inlet 1.5 g/m³, removal rate above 23 s at retention 94.4%, removal load 333.16 g/(m³·h), kinetic maximum load 666.7 g/(m³·h), saturation constant 0.87 g/m³; pressure drop rises with biofilm and elemental sulfur accumulation, requiring bubble backwashing.
- Hasanzadeh V. et al., biofilter with mixed polyurethane foam and palm fiber packing for hydrogen sulfide removal, at EBRT 47 s and inlet 288 mg/m³ the removal rate was 100%, maximum removal load 24.1 g/(m³·h) (removal rate 86.1% at load 28.0), packing sulfate accumulation 10.8 mg/g, pH decreased below 2.1, pressure drop throughout less than 5 mm. J Mazandaran Univ Med Sci.
- "A Biotrickling Bed for Treating Odor Pollutants in Air" patent document: GRT 19 s, inlet less than 350 mg/m³ (load 120 g/(m³·h)), at GRT 12 s with inlet greater than 270 mg/m³ the removal rate still greater than 90%, pressure drop 180 to 280 Pa/m, backwashing cycle greater than two months.
- Huaian Sijiqing Wastewater Treatment Plant odor removal project: retrofit part 6.5 万 m³/d, air volume 5 万 m³/h, investment 1382.04 万 yuan; expansion part 4 万 m³/d, air volume 1.9 万 m³/h, investment 685.55 万 yuan; total 2067.59 万 yuan, biological filter method assisted by chemical absorption.
- Odor treatment at the wastewater station of a papermaking enterprise: before covering, the surrounding hydrogen sulfide maximum 9 mg/m³, after covering 0 to 0.05 mg/m³; investment for sending to boiler incineration 800 万 yuan, operation 147 万 yuan/year, compared with biological filter 1200 万 yuan or more, 332.31 万 yuan/year, saving 184.69 万 yuan per year.
- Odor removal equipment 2026 年 quotation data by air volume tier (5000 to 1 万 m³/h quoted at 8 to 15 万 yuan, etc.) and the "converted unit price" column in the text, used for back-calculation verification in Section 10 of this paper.
- "Sharing of Standards and Specifications Related to Odor Treatment" compilation: DB31/1025—2016 Shanghai Odor (Malodor) Pollutant Emission Standard Article 4.5 (stack not less than 15 m; when not meeting standards, emission rate strictly 50% or removal efficiency not less than 98%), Article 5.2 (odor concentration instantaneous sampling takes the maximum value).
- Huzhou Municipal People's Government Administrative Reconsideration Decision (Huzhengfu [2023] No. 120): a third-party testing institution failed to sample once every 2 h for a total of 4 times in accordance with HJ 905—2017, and was found to have falsified monitoring data.
Across multiple industries nationwide (municipal and industrial park wastewater
Small to medium and up to ultra-large scale (single-pool collection of 3,000 to