Disinfection: Soaking in the Tank for 30 Minutes, Only 9 Minutes Actually Disinfect
The previous article discussed the retention time for odor at "15 seconds," while this article discusses the retention time for disinfection at "30 minutes"—but neither of these numbers represents the time actually experienced by microorganisms in engineering terms. 30 minutes is the tank volume divided by the flow rate; 9 minutes is the portion of the same tank that can truly be used for disinfection when baffling is poorly designed. The 21 minutes in between is the time water spends sitting in dead zones.
I. Positioning Correction: Disinfection Is Not About "How Much Was Added" but "How Long It Acted"
The disinfection stage in a wastewater treatment plant is usually the shortest: one chemical dosing pipe, one contact tank, one online residual chlorine analyzer, and two columns of numbers on the report—dosage and residual chlorine. It looks like a closed loop. But disinfection is the stage in the entire line that is accepted by "dose" rather than "concentration," and dose is the product of two numbers: disinfectant concentration multiplied by its contact time with microorganisms. Filling in only one of these columns makes the closed loop false.
The trouble is that there are four quantities in this chain, all with "chlorine" in their names and all in mg/L, yet they cannot substitute for one another in engineering. Table 1 places them side by side.
| Name | Definition | Unit | Determined by | Most common misuse |
|---|---|---|---|---|
| Dosage (chlorine dose) | Total amount of disinfectant entering the water, expressed as Cl₂ | mg/L | Chemical dosing pump stroke, design value | Recording it in reports as residual chlorine |
| Chlorine demand | The portion consumed by ammonia nitrogen, nitrite, ferrous iron, sulfide, organics and microorganisms | mg/L | Influent water quality, fluctuating at any time | Neither measured nor estimated, so it is inexplicable when residual chlorine occasionally drops to zero |
| Residual chlorine | Chlorine still capable of oxidation at the end of contact, in three forms: free, combined and total | mg/L | Dosage minus chlorine demand | Writing only "residual chlorine" without specifying which type |
| CT value | Residual chlorine × effective contact time (T10) | mg·min/L | Tank configuration, baffling, flow rate, water quality | Using nominal retention time in place of T10 |
The relationship among the four is just one equation:
Dosage − Chlorine Demand = Residual Chlorine CT = Residual Chlorine × T10
This equation illustrates two things. First, with the same dosage, residual chlorine can be completely different—when ammonia nitrogen rises from 1 mg/L to 3 mg/L, the theoretical chlorine demand rises from 7.6 to 22.8 mg/L (see Section 5); with the same dosage of 4 mg/L, the former still has some residual chlorine left, while the latter has none at all. Second, with the same residual chlorine, CT can be completely different—with the same residual chlorine of 0.5 mg/L, a tank with good baffling versus poor baffling can differ in CT by 2.3 times. If either of these two factors is missing, disinfection cannot be verified, and one can only "feel it's probably fine."
II. 30 minutes is tank volume divided by flow: for a 1 万-ton plant, the tank only needs 208 cubic meters
Let us first go through the step most easily assumed to be "already calculated." At a scale of 1 万 m³/d, equivalent to 416.7 m³/h, 6.94 m³/min. Sizing the tank for a 30 min contact time:
V = 6.94 m³/min × 30 min = 208 m³
208 m³ is roughly a tank of 6 m × 6 m × 5.8 m, or two channels 20 m long, 1.5 m wide, with 3.5 m water depth. This volume in many plants is the "disinfection channel," which does not look large, but it is compliant by code—because the code states "contact time not less than 30 min," and 208 ÷ 6.94 is exactly 30.
The problem lies in the next step: not every drop of water in these 208 m³ stays for 30 minutes. Some portion enters from the inlet, goes around along the tank wall, and exits, possibly staying only 3 minutes; another portion is retained in corners and cannot get out even in an hour. Disinfection only recognizes "the fastest-traveling batch of water"—because as long as one batch of water is not fully inactivated, the fecal coliform in the effluent is determined by that batch.
In engineering, T10 is used to describe this: after dosing a tracer, the time required for 10% of the tracer to cumulatively appear at the outlet. It represents how long "the fastest-traveling 10% of the water" stays, while 90% of the water stays longer than that. The ratio of T10 to the nominal hydraulic detention time (HDT) is called the baffling factor (BF, translated in some literature as volume utilization coefficient):
T10 = BF × HDT = BF × V ÷ Q CT = C × T10
If BF is not measured, it can only be estimated by tank type. The U.S. EPA provides a six-tier table in the disinfection profiling technical guidance for the LT1ESWTR, which is widely followed in domestic literature and by design institutes. Placing it side by side with the benchmark of 208 m³, Table 2 is obtained.
| Baffling Condition | BF | T10 (min) | Tank Volume Required to Achieve T10 of 30 min (m³) | Multiple Relative to 208 m³ |
|---|---|---|---|---|
| No baffling, inlet and outlet adjacent | 0.1 | 3.0 | 2 083 | 10.0 |
| Poor: single/multiple inlets and outlets, no in-tank baffling | 0.3 | 9.0 | 694 | 3.33 |
| Average: baffled inlet and outlet, 2 or more in-tank baffles | 0.5 | 15.0 | 417 | 2.00 |
| Good: perforated inlet, 2 or more serpentine or perforated baffles, outlet weir | 0.7 | 21.0 | 298 | 1.43 |
| Near plug flow: length-to-width ratio of 5:1 or more | 0.9 | 27.0 | 232 | 1.11 |
| Plug flow (ideal) | 1.0 | 30.0 | 208 | 1.00 |
The most striking row in this table is the second one. The tank configuration of the vast majority of existing disinfection channels falls between "Poor" and "Average"—a straight-through corridor with the inlet at one end and the outlet at the other, and no guide walls in between. With a BF of 0.3, 30 min is only 9 min. To bring T10 up to 30 min at the same BF, the tank would have to be expanded from 208 m³ to 694 m³, adding 486 m³ of concrete.
III. Why the code specifies 30 minutes: the clause commentary itself points out "dead zones and short-circuiting"
The original text of Article 7.13.10 of GB 50014—2021 states: "After disinfection with chlorine dioxide, sodium hypochlorite, or chlorine, mixing and contact shall be carried out, and the contact time shall not be less than 30min." The rationale given in the clause commentary is almost the Chinese version of the concept of T10:
Reading this sentence twice reveals a structural gap: it acknowledges dead zones and short-circuiting, yet does not define 30 min as T10. The clause uses 30 min to "cover" the loss caused by short-circuiting, which is equivalent to using an oversized nominal time to offset an undersized baffling factor. This approach is safe at the design stage because it leaves a margin; but at the operation stage it becomes a trap—if a tank has a nominal 30 min and a BF of only 0.3, then it is built according to the code and verified according to the code, yet its actual effective time is only 9 min, and no acceptance form will check this 9.
What is more troublesome is that this gap is filled on the water supply side. GB 50013 "Standard for Design of Outdoor Water Supply" and the design practices for clear water tanks in various regions all require verification of effective contact time, and the industry generally accounts by T10. For the same matter, water supply is calculated by T10 while wastewater is calculated by HDT; the two calculation methods coexist in different plants of the same group, so the reports naturally do not match.
IV. Baffles are the cheapest disinfection capacity in this system
Add two guide walls to a tank of 208 m³, raise BF from 0.3 to 0.7, and with the tank volume unchanged and the chemical dosage unchanged, T10 changes from 9 min to 21 min. If the residual chlorine is maintained at 0.4 mg/L, CT increases from 3.6 to 8.4 mg·min/L, an increase of 2.3 times. This investment is just a few concrete walls, whereas if the same 2.3 times were to be obtained by building new tank volume, an additional 486 m³ would need to be excavated, along with an additional set of depreciation and cleaning for the tank body.
| Item | Before Retrofit (BF 0.3) | After Adding Baffle Walls (BF 0.7) |
|---|---|---|
| Effective Contact Time T10 | 9.0 min | 21.0 min |
| CT Value | 3.6 mg·min/L | 8.4 mg·min/L |
| Tank Volume | 208 m³ | 208 m³ |
| Dosage | Unchanged | Unchanged |
| Civil Works Cost | — | Two baffle walls; compared with building a new 486 m³ tank |
| Side Effects | — | Head loss increases slightly; the elevation of the outlet weir needs to be rechecked |
The side effects must be stated clearly: adding baffles increases head loss, and after the flow velocity distribution in the tank changes, tanks that originally relied on gravity outflow may need the weir crest raised or outlet regulation added. This is not free, but compared with 486 m³ of concrete, the magnitude is far smaller. The industry calls this cost item "the cheapest disinfection capacity," and that is exactly what it refers to—it does not add chemicals, and therefore does not increase by-products, a point that will become important in Section 6.
V. 3 to 5 mg/L Cannot Reach the Breakpoint: Plants Meeting Class 1A Are Actually Running Chloramine Disinfection
GB 50014—2021 Article 7.13.9 specifies "where no test data are available, 5mg/L to 15mg/L may be adopted," and the clause explanation further narrows this to empirical operating values: when effluent reaches Class 1B, the chlorine dosage is 5 to 9 mg/L; when it reaches Class 1A, 3 to 5 mg/L. The figure of 3 to 5 mg/L is the one most worth pursuing throughout this article.
The tool for pursuing it is the stoichiometric relationship of breakpoint chlorination: ammonia nitrogen is oxidized by chlorine to nitrogen gas, and the theoretical chlorine demand is 7.6 mg Cl₂ per mg of ammonia nitrogen (1.5 mol Cl₂ to 1 mol N, 1.5 × 71 ÷ 14 = 7.61). Before the breakpoint, nearly all chlorine is converted to chloramine; only after crossing the breakpoint does free chlorine appear. Substituting the ammonia nitrogen typical of Class 1A effluent:
| Effluent Ammonia Nitrogen (mg/L, as N) | Theoretical Breakpoint Chlorine (mg/L) | Position of 3 to 5 mg/L Dose | Dominant Form at End of Contact |
|---|---|---|---|
| 0.2 | 1.5 | Past breakpoint | Free chlorine dominant |
| 0.5 | 3.8 | Near critical point | Free chlorine and chloramines coexist |
| 1.0 | 7.6 | Before breakpoint | Monochloramine |
| 2.0 | 15.2 | Before breakpoint | Monochloramine |
| 3.0 | 22.8 | Before breakpoint | Monochloramine (with a small amount of dichloramine) |
| 5.0 | 38.0 | Before breakpoint | Monochloramine dominant |
The ammonia nitrogen limit for Grade A is 5 (8) mg/L, and actual operation mostly ranges from 0.5 to 3 mg/L. That is to say, except for the few plants with ammonia nitrogen below 0.5, a chlorine dose of 3 to 5 mg/L simply cannot reach the breakpoint, and the resulting disinfectant is predominantly monochloramine, not free chlorine. This is not an operational error, but an inevitable outcome jointly determined by the recommended value in the standard and the actual water quality.
This is the same kind of accounting as the "available chlorine 8.34 kg/kg hydrogen sulfide" discussed in the previous article on odors: the chlorine dosed in is not counted as a "disinfectant" but is first consumed by "reducing substances." Ammonia nitrogen is only the largest item; after it come nitrite, ferrous iron, and sulfide (see Section 8). Only what remains after the chlorine demand is satisfied is called residual chlorine.
VI. The Three Numbers of Residual Chlorine: The 0.5 on the Report May Be Half Chloramine That Cannot Fight
HJ 586—2010 divides residual chlorine into three terms with very clear definitions, yet in engineering they are often collapsed into one: free chlorine is elemental chlorine, hypochlorous acid (active free chlorine), and hypochlorite (potential free chlorine); combined chlorine is monochloramine, dichloramine, nitrogen trichloride, and organic chloramines; total chlorine is the sum of the two. In measurement, DPD directly develops color to read free chlorine; after adding excess potassium iodide and developing color again, total chlorine is read, and the difference is combined chlorine.
| Name | Composition | Measurement | Disinfection Efficacy |
|---|---|---|---|
| Free Chlorine | Elemental chlorine, hypochlorous acid (active) + hypochlorite (potential) | DPD direct color development, 515 nm | Strong; at the same pH, hypochlorous acid is approximately 80 times that of hypochlorite |
| Combined Chlorine | Monochloramine, dichloramine, nitrogen trichloride, organic chloramines | Total chlorine minus free chlorine | Weak; the CT required for the same inactivation rate is more than one order of magnitude higher |
| Total Chlorine | All of the above | Color development after adding excess potassium iodide | A mixed value; cannot be directly substituted into CT |
The proportions of these three numbers in actual water have a set of verifiable measured data. A chlorination test on secondary effluent from a certain municipal wastewater treatment plant (implementing Grade A) published in China Water & Wastewater 2021 年 provided a complete set: at a contact time of 12 min and an effective chlorine dosage of 3.67 mg/L, the log removal rate of fecal coliforms reached above 2.5 lg, at which point the ORP was 578 mV, total chlorine CT value 7.6 mg·min/L, free chlorine CT value 3.3 mg·min/L.
Divide the two CT values to back-calculate the concentrations: Total Chlorine 7.6 ÷ 12 = 0.633 mg/L, Free Chlorine 3.3 ÷ 12 = 0.275 mg/L, Combined Chlorine 0.633 − 0.275 = 0.358 mg/L, accounting for 56.6% of the residual chlorine. In other words, if this plant's report states "Residual Chlorine 0.63", only 0.275 of it is the chlorine that can actually do the job.
VII. The same CT is surplus for free chlorine but a shortfall for chloramine
Chloramine is not "a milder form of chlorine"; it follows an entirely different kinetics. The Health Canada drinking water guidelines cite the CT tables of Hoff (1986) and USEPA (1999), listing the requirements of four disinfectants under 5 ℃ and 99% inactivation conditions together. Three targets are extracted:
| Target Microorganism | Free Chlorine | Monochloramine | Ratio |
|---|---|---|---|
| Escherichia coli | 0.034 to 0.05 | 95 to 180 | Approx. 2 800 times (95 ÷ 0.034) |
| Giardia | 65 to 93 | 1 470 | Approx. 23 times (1 470 ÷ 65) |
| Viruses | 4.0 | 857 | Approx. 214 times (857 ÷ 4.0) |
The Giardia table in US Code of Federal Regulations 40 CFR 141.74 can be cross-checked: for 99.9% inactivation, 25 ℃, pH 7, and residual chlorine 1.0 mg/L, free chlorine requires a CT of 37, while monochloramine requires 750, exactly 20 times; when the temperature drops to 5 ℃, monochloramine rises to 2 200, and below 1 ℃ it rises to 3 800—chloramine is extremely sensitive to temperature, whereas free chlorine is far less sensitive in this respect.
Now apply this table back to the report of a Class 1A plant. If the plant writes "Total residual chlorine 0.5, contact 30 min", then CT = 15 mg·min/L. Where does this 15 fall:
- If 0.5 is all free chlorine: inactivation of E. coli 99% requires only 0.034 to 0.05, a surplus of 300 to 440 times; it is also sufficient for viruses (requires 4.0). This is genuinely compliant disinfection.
- If 0.5 is all monochloramine: E. coli requires 95 to 180, a shortfall of 6 to 12 times; viruses require 857, a shortfall of 57 times. The "compliance" on the report does not hold on the microbiological side.
And according to the estimation in Section 5, for a Class 1A plant under the conditions of dosing 3 to 5 mg/L and ammonia nitrogen 1 to 3 mg/L, the main product is chloramine. The measured results in Section 6 again give a combined chlorine fraction of 56.6%. The two agree: in the "residual chlorine compliance" of these plants, more than half of the numbers barely translate into disinfection capacity in the CT ledger.
8. CT values cannot be copied across plants: 0.2 to 33.6, the same indicator differs by 168 times
CT values are useful because they compress "concentration" and "time" into a single number; they are dangerous also because, once compressed, you cannot tell what was there before compression. Table 7 puts together several sets of numbers that can be found; note that the C and T bases differ for each row.
| Source | Dosage (mg/L) | Contact Time | Basis of C | CT (mg·min/L) |
|---|---|---|---|---|
| Intelligent dosing study at a certain plant (2024, LSTM feedback control) | — | — | Residual chlorine (critical value) | 0.20 |
| Optimization study in Guangxi (filter effluent, contact ≥10 min) | 1.0 | 30 min | Total residual chlorine 0.02 to 0.16 | 0.6 to 4.8 |
| A certain plant in Wuxi (2021, China Water & Wastewater) | 3.67 | 12 min | Free chlorine | 3.3 |
| Same as above | 3.67 | 12 min | Total chlorine | 7.6 |
| Converted from the recommended lower limit of GB 50014 (assuming total residual chlorine 0.5) | 3 to 5 | 30 min (nominal) | Total chlorine | 15 |
| Survey average of plants meeting high discharge standards nationwide | 3.69 | 30 min (nominal) | Total residual chlorine 1.12 | 33.6 |
From 0.20 to 33.6, a factor of 168. This span is not a data conflict, but rather four things that have not been unified: whether C is free or total, whether T is nominal or T10, whether the dosage includes the chlorine demand, and whether the critical value is "just meeting the standard" or "leaving a margin." Therefore, there is only one correct way to use CT values—compare longitudinally within the same plant and under the same basis, using it to judge whether today is thinner or thicker than yesterday; cross-plant horizontal comparison must first align the basis.
There is another counterintuitive finding hidden in the second row of Table 7: when the dosage is reduced from 3.69 to 1.0, a decrease of 73%, the effluent still meets standards. The reason is not that disinfection has become stronger, but that the contact time has been preserved from the nominal 30 min (and the filter effluent SS is lower, requiring less chlorine). This has great significance for operation—the way to save chemicals is not in the dosing room, but in the tank configuration and pretreatment.
IX. Phosphorus removal chemicals consume chlorine: iron content of 3% is a watershed
A study in China Water & Wastewater 2024 年 applied the CT value to chlorination in wastewater treatment plants, and one conclusion is easily overlooked: if the iron content of phosphorus removal chemicals exceeds 3%, it will hinder the disinfection effect of sodium hypochlorite, and plants using such chemicals should appropriately increase the effective concentration of disinfectant. This connects to the account discussed in the previous article on Total Phosphorus—to reduce Total Phosphorus from 0.5 to 0.3, plants often increase PAC or iron salt dosing, and while increasing the dosage, the chlorine demand in the disinfection stage also rises.
How much can be explained? According to stoichiometry, ferrous iron is oxidized by chlorine to ferric iron, requiring 0.636 mg Cl₂ per milligram of iron (2Fe²⁺ + Cl₂ → 2Fe³⁺ + 2Cl⁻, 71 ÷ 111.7). If PAC is dosed at 30 mg/L with an iron content of 4%, this introduces 1.2 mg/L of iron, requiring 0.76 mg/L of chlorine calculated as ferrous iron, equivalent to 15% to 25% of the dosage 3 to 5 mg/L.The chemical itself can explain ten to twenty percent; the remaining inhibition more likely comes from iron-catalyzed decomposition and complexation consumption of chlorine, as well as floc entrapment of microorganisms—this layer is an inference; the literature only provides the phenomenon that "exceeding 3% will hinder" without giving a mechanistic breakdown, and is cited here as a phenomenon.
| Substance | Reaction | mg Cl₂ / mg | Scenario Relevant to This Article |
|---|---|---|---|
| Ammonia Nitrogen (as N, to breakpoint forming N₂) | 2NH₃ + 3HOCl → N₂ + 3HCl + 3H₂O | 7.61 | Chloramines form first before breakpoint; this is the largest item |
| Nitrite (as N) | NO₂⁻ + HOCl → NO₃⁻ + HCl | 5.07 | Effluent from partial nitrification or incomplete denitrification |
| Ferrous Iron (as Fe) | 2Fe²⁺ + Cl₂ → 2Fe³⁺ + 2Cl⁻ | 0.636 | Iron salt phosphorus removal chemicals, groundwater iron removal |
| Manganese (as Mn) | Mn²⁺ + Cl₂ + 2H₂O → MnO₂ + 4H⁺ + 2Cl⁻ | 1.29 | Manganese-containing groundwater, some industrial wastewater |
| Sulfide (as S) | S²⁻ + 4HOCl → SO₄²⁻ + 4HCl | 8.86 | Same source as 8.33 (as H₂S) in the sulfur-containing wastewater article |
This table is used to estimate the lower limit of chlorine demand, not an exact value. The actual chlorine demand also includes consumption by organics and microorganisms, which can only be measured: take effluent from the contact tank, measure total chlorine and free chlorine, and back-calculate. A more practical engineering approach is to change "dosage" to "feedback dosing based on residual chlorine," letting the dosing pump absorb fluctuations in chlorine demand—the study in Table 7 that reduced the dosage from 3.69 to 1.0 essentially did exactly this.
X. Ultraviolet: The Effective Dose Requires Two Discounts, and the Two Sets of Coefficients Differ by a Factor of 2.3
The ultraviolet line looks cleaner than chlorination: no chemical dosing, no trihalomethane formation, and no residual chlorine. But it has a pitfall isomorphic to CT—the "effective dose" is calculated, not measured, and the calculation requires multiplying by two reduction coefficients.
Article 7.13.6 of GB 50014—2021 specifies the effective dose: 15 to 25 m J/cm² is recommended for secondary treatment effluent, and 24 to 30 m J/cm² for reclaimed water. Between the effective dose and the equipment's nominal initial output lie two reductions: lamp aging and quartz sleeve fouling. And as for how to determine these two coefficients, the two documents do not provide the same set:
| Basis | Aging Factor | Fouling Factor | Product | Initial Output Required for 20 mJ/cm² (mJ/cm²) |
|---|---|---|---|---|
| GB/T 19837—2019 Default Values (when not verified by a third party) | 0.5 | 0.6 | 0.30 | 66.7 |
| Optimal Combination under Product Technical Requirements (Low Pressure High Output 80%, Mechanical Cleaning 85%) | 0.80 | 0.85 | 0.68 | 29.4 |
| Common Combination under Environmental Product Technical Requirements (Low Pressure 70%, Mechanical plus Chemical 95%) | 0.70 | 0.95 | 0.665 | 30.1 |
| Values Adopted for the Hefei Wangxiaoying Project | 0.5 | 0.8 | 0.40 | 50.0 |
Between the most conservative 0.30 and the most lenient 0.68, the difference is 2.27 times. The number of lamps is inversely proportional to the reduction factor, so for the same statement "effective dose not less than 20 mJ/cm²", configuring according to 0.30 requires an initial output of 66.7, while configuring according to 0.68 requires only 29.4, a difference of more than double in equipment quantity. Which is correct? Both are correct; the difference lies in whether there is a third-party verification report—GB/T 19837—2019 states it directly: the aging factor and fouling factor shall be determined by a qualified third party using test reports of similar equipment operating under similar water quality; without a report, the default values of 0.5 and 0.6 shall be used.
XI. The timescale of UV is seconds: 4 to 8 seconds, while chlorination is 30 minutes
UV and chlorination are often compared side by side, but their "time" is not the same physical quantity. Chlorination is measured as concentration multiplied by time (mg·min/L), while UV is measured as intensity multiplied by time (mJ/cm²); both units contain "multiplied by time," yet their dimensions are completely different. In engineering terms, the most intuitive difference is the timescale:
A national survey of UV disinfection at urban wastewater treatment plants published in China Water & Wastewater found that the design irradiation retention time at each plant was basically 4 to 8 s, with little difference between design and actual values; this differs from the specified chlorination contact time of 30 min by more than 200 times. The reason is not hard to understand—UV does not need to "soak"; photons hitting nucleic acids complete the damage, whereas chlorine must penetrate cell walls and disrupt enzyme systems, relying on sustained contact. Therefore, UV basins are small and chlorination basins are large, and the part that cannot be interchanged is residual disinfection capability: UV disappears the moment the lamps are turned off, leaving no residual in the effluent pipe network.
The same survey also provided two failure cases, which are more useful than parameters. Plant 2 designed its UV dose based on the average effluent flow of the biological tank, but it uses the CASS process with intermittent effluent and has no buffer equalization tank; the actual flow occurs at the moment of decanting, so the dose is insufficient during peak periods. Plant 6 is small in scale and still subject to Class 1A standards; the lamp power selected for the equipment was too low, and the dose itself did not meet the standard. The common point of both cases is: the dose figure passes on the drawings but fails on the flow curve.
XII. By-products: ammonia nitrogen both saves and ruins disinfection; yet wastewater standards have no such column
The cost of disinfection is by-products, and this is tightly regulated in drinking water. GB 5749—2022 splits trihalomethanes into four sub-items: chloroform 0.06, bromodichloromethane 0.1, dibromochloromethane 0.06, and bromoform 0.1 mg/L; the total trihalomethanes is not a simple sum but the sum of the ratios of each sub-item's measured concentration to its limit not exceeding 1—a dimensionless ratio sum. This formulation is often written in local water quality disclosures as "trihalomethanes 1.0 mg/L"; the two statements are not the same thing: one is a ratio, the other is a concentration.
The same standard also specifies three other disinfectant by-products: chlorite 0.7 (when using chlorine dioxide), bromate 0.01 (when using ozone), and chlorate 0.7. None of these three items appear in GB 18918—2002, nor in the GB/T 19923 reclaimed water standard. In other words, disinfection of wastewater and reclaimed water only assesses microorganisms, not what it itself generates. This is a real gap in this standards system, not a typo.
How large is the gap? Two-year monitoring of three wastewater reuse plants in northeastern Spain (Matamoros et al., 2007, Water Research) reported total trihalomethanes of 2 to 30 μg/L, with dosing at two levels (2 to 5 and 16 mg/L Cl₂), far below the drinking water standard of 80 to 150 μg/L at the time. However, the same study gave three conclusions contrary to intuition:
- The higher the ammonia nitrogen, the lower the trihalomethanes. This is because chlorine is first scavenged by ammonia nitrogen to form chloramines, and the ability of chloramines to form trihalomethanes is far weaker than that of free chlorine. This correlation is significant in the dataset of the Platja d'Aro plant (p<0.05).
- Bromide at 0 to 1 mg/L significantly raises total trihalomethanes, because brominated species form faster. Coastal plants and bromide-containing industrial wastewater require special attention.
- Ultraviolet irradiation before disinfection has no statistical effect on either the formation or the removal of trihalomethanes; UV also does not alter trihalomethanes that have already formed.
The first point is the one this article most wants to leave with you: ammonia nitrogen plays two roles simultaneously in this system—it converts chlorine into chloramines, so byproducts decrease (a good thing), but disinfection capacity also drops by an order of magnitude (a bad thing). This is not a win-win; it is a trade-off. When any plant makes a choice between "reducing ammonia nitrogen" and "maintaining residual chlorine," it is actually shifting between byproducts and disinfection capacity, both of which are invisible—only when CT and THM are recorded simultaneously can they be seen.
| Method | Specified Parameters | Time Scale | Advantages | Shortcomings |
|---|---|---|---|---|
| Sodium Hypochlorite | Grade I-A chlorination 3 to 5, Grade I-B 5 to 9, no data 5 to 15 mg/L; contact ≥30 min; solution storage ≤7 d, room temperature ≤30 ℃ | Minutes | Residual chlorine; low cost; simple operation | Efficacy drops sharply after chloramination; forms trihalomethanes; reagent degrades easily |
| Chlorine Dioxide | Contact with water ≥30 min (drinking water basis 0.1 to 0.8 mg/L) | Minutes | Strong inactivation; little pH influence; no trihalomethane formation | Forms chlorite; requires on-site generation; high cost |
| Ozone | Determined by testing or experience | Tens of seconds to several minutes | Strongest oxidizing capability; simultaneous decolorization and odor removal | Forms bromate; no persistent residual; off-gas requires destruction |
| Ultraviolet | Effective dose 15 to 25 (secondary), 24 to 30 (reclaimed water) mJ/cm² | Seconds (design 4 to 8 s) | No chemical dosing; no trihalomethane formation; no residual chlorine | No persistent residual; sensitive to SS and UVT; photoreactivation occurs |
XIII. Acceptance Checklist: Making the Disinfection Account Auditable
The previous twelve sections all break down the definitions; when it comes down to a single acceptance form, there are only seven items. Among these seven, the first three determine "what the disinfection dose actually is," and the last four determine "whether this number is real."
| No. | What to Check | How to Check | Typical Signs of Non-Compliance |
|---|---|---|---|
| 1 | Effective volume of the contact tank and the number of baffle channels in the tank | Measure the tank, count the baffle walls; calculate HDT = V ÷ Q | Only one straight-through channel, actual BF 0.3 |
| 2 | Whether T10 has been calculated | If conditions permit, conduct a tracer test (sodium fluorescein or salt water + conductivity meter); if not, select BF according to tank type | The report only has "contact time 30 min", with no T10 |
| 3 | Which type of residual chlorine is reported | Measure both free chlorine and total chlorine; record the difference as combined chlorine | Only "residual chlorine" is reported, and free and total chlorine are identical (indicating the two-step measurement was not performed) |
| 4 | Whether chlorine demand has been actually measured | Dosage minus residual chlorine; compare with ammonia nitrogen × 7.61 | Dosed 4 mg/L, residual chlorine 0, yet reported as 0.5 |
| 5 | Whether samples are dechlorinated | Add sodium thiosulfate to water samples for fecal coliform testing | No dechlorination; colony counts lower by 10 to 1 000 times |
| 6 | Source of the UV reduction factor | Check the third-party dose validation report | Using the manufacturer's sample "initial output" as the effective dose |
| 7 | Which flow rate is used for UV design | For intermittent decant processes, the peak decant flow must be used | Sized based on average flow; insufficient dose during peak periods |
Item five deserves separate mention, because among the seven items, this is the only one whose deviation direction is "favorable to the plant." The chlorinated water sample still carries residual chlorine; after being placed in the sampling bottle, it continues to disinfect, and by the time it reaches the laboratory, a batch of bacteria has already died. A study conducted a controlled comparison: the fecal coliform count in non-dechlorinated water samples was significantly lower than that in dechlorinated water samples, and the values for dechlorinated water samples can be 10 to 1 000 times higher than those for non-dechlorinated water samples. This means that if a plant does not dechlorinate its samples, its colony data will be systematically low—and the direction of being low happens to be reassuring. The same study also warned that large fluctuations in the instantaneous flow rate of the disinfection stage influent and the decay of available chlorine in sodium hypochlorite in the storage tank will directly affect the effectiveness—when sodium hypochlorite solution is stored for more than 7 天 and the room temperature exceeds 30 ℃, the available chlorine drops significantly.
One last point about the measurement itself: HJ 586—2010 explicitly states that "this standard is not applicable to the determination of relatively turbid or highly colored water samples," while the color of wastewater treatment plant effluent often ranges from 30 to 50 units. The method provides two ranges: 10 mm cuvette with a detection limit of 0.03 mg/L and a determination range of 0.12 to 1.50; 50 mm cuvette with a detection limit of 0.004 and a range of 0.016 to 0.20. Choosing the wrong range results in no color development or exceeding the upper limit, while positive interference from color and turbidity causes readings to be elevated—elevated residual chlorine and depressed colony counts are two illusions in the same direction.
XIV. Condensing This Article into Five Sentences
- 30 minutes is tank volume divided by flow rate.For a plant of 1 万 m³/d, 208 m³ equals "30 minutes"; there are no baffles in the tank, BF is only 0.3, and the actual contact time available for disinfection is 9 minutes.
- The clause explanation itself points out "dead zones and short-circuiting," yet does not define 30 min as T10.At the design stage this is margin; at the operational stage this is a blind spot—no acceptance checklist will ever check that 9.
- 3 to 5 mg/L cannot reach the breakpoint.With Grade 1A effluent ammonia nitrogen at 1 to 3 mg/L, the theoretical breakpoint chlorine is 7.6 to 22.8 mg/L, and the product of dosing 3 to 5 is predominantly monochloramine; in field measurements, combined chlorine accounts for 56.6% of residual chlorine.
- The same CT = 15 represents a 300-fold surplus for free chlorine but a 6 to 12-fold shortfall for chloramines.Residual chlorine is inventory; CT is fighting strength; half the inventory is chloramine that cannot fight.
- UV replaces "time" with "intensity times time," but the dose must be discounted twice.The difference between 0.5 × 0.6 and 0.8 × 0.85 is 2.27-fold; the same phrase "20 mJ/cm²" can specify equipment that differs by more than a factor of two.
References
- GB 50014—2021 "Standard for Design of Outdoor Wastewater Engineering," Articles 7.13.1 to 7.13.4 (degree of disinfection, optional methods, ecological safety, and alignment with GB 50013).
- GB 50014—2021, Articles 7.13.5 to 7.13.8: open-channel ultraviolet disinfection systems, online mechanical plus chemical cleaning; effective dose 15 to 25 mJ/cm² for secondary treatment effluent and 24 to 30 mJ/cm² for reclaimed water; the length of the irradiation channel upstream and downstream of the lamps should not be less than 1 m, water level detection and control shall be provided, and modules shall be capable of maintenance without shutdown.
- GB 50014—2021, Articles 7.13.9 to 7.13.11: chlorine dosage determined by testing or experience, and 5 to 15 mg/L where no data are available; contact time for chlorine dioxide/sodium hypochlorite/chlorine disinfection shall not be less than 30 min; sodium hypochlorite shall be stored at low temperature and protected from light, at room temperature preferably not exceeding 30 ℃, and storage time preferably not exceeding 7 d.
- GB 50014—2021, Article 7.13.9 explanatory notes: based on domestic operating experience, chlorine dosage is 5 to 9 mg/L when effluent reaches Grade 1B and 3 to 5 mg/L when it reaches Grade 1A.
- GB 50014—2021, Article 7.13.10 explanatory notes: "Considering that dead zones and short-circuiting may occur in the flow within the contact tank, in order to improve and ensure the disinfection effect, it is stipulated that... the contact time shall not be less than 30min."
- GB 50014—2021, Article 7.13.6 explanatory notes: cites the provision of GB/T 19837 that the effective UV dose for reclaimed water shall not be less than 80 mJ/cm², as well as the recommendation to combine UV with chlorine-containing disinfectants to compensate for insufficient persistent disinfection capacity.
- GB 5749—2022 "Standards for Drinking Water Quality," Table 1 and Table 3: free chlorine ≥0.3 and ≤2 mg/L at the plant outlet, ≥0.05 in the distribution network, with contact ≥30 min; total chlorine (chloramine disinfection) 0.5 to 3 at the plant outlet, with contact ≥120 min; chlorine dioxide 0.1 to 0.8, with contact ≥30 min; chloroform 0.06, monochlorodibromomethane 0.1, dichlorobromomethane 0.06, bromoform 0.1 mg/L, with the sum of the ratios of measured values to limits for individual trihalomethane species not exceeding 1; chlorite 0.7, chlorate 0.7, bromate 0.01 mg/L.
- GB 18918—2002 "Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant," Table 1: fecal coliform count 1000 CFU/L for Grade 1A and 10000 CFU/L for Grade 1B.
- HJ 586—2010 "Water Quality—Determination of Free Chlorine and Total Chlorine—N,N-Diethyl-1,4-Phenylenediamine Spectrophotometric Method": definitions and composition table of free chlorine (active free chlorine comprising elemental chlorine and hypochlorous acid; potential free chlorine being hypochlorite), combined chlorine (chloramines and organic chloramines), and total chlorine; with 10 mm cuvette, detection limit 0.03 mg/L, determination range 0.12 to 1.50 mg/L; with 50 mm cuvette, detection limit 0.004 mg/L, range 0.016 to 0.20 mg/L; not applicable to relatively turbid water samples or those with high color.
- GB/T 19837—2019 "Ultraviolet Disinfection Equipment for Urban Water Supply and Drainage": where not verified by a third party, the UV lamp aging factor shall take the default value 0.5 and the quartz sleeve fouling factor the default value 0.6; the transmittance of clean quartz sleeves at 253.7 nm shall not be less than 90%.
- "Technical Requirements for Environmental Protection Products: Ultraviolet Disinfection Devices" (Ministry of Ecology and Environment): low-pressure lamp life not less than 8 000 h, low-pressure high-intensity lamp 12 000 h, medium-pressure lamp 5 000 h; aging factor for low-pressure lamps not less than 70% after 8 000 h, low-pressure high-intensity lamps not less than 80% after 12 000 h, medium-pressure lamps not less than 70% after 5 000 h; fouling factor not less than 85% for mechanical cleaning and not less than 95% for mechanical plus chemical cleaning; bioassay-verified dose for reclaimed water ≥80 mJ/cm² (T₂₅₄ ≥65%), ≥40 mJ/cm² (SS ≤5 mg/L, T₂₅₄ ≥70%).
- USEPA, Long Term 1 Enhanced Surface Water Treatment Rule: Disinfection Profiling and Benchmarking Technical Guidance Manual (EPA 816-R-03-004, 2003), baffling factor table—no baffling 0.1, poor 0.3, average 0.5, good 0.7, near plug flow 0.9, plug flow 1.0.
- 40 CFR 141.74 appendix: 99.9% inactivation of Giardia lamblia, CT 37 for free chlorine at 25 ℃, pH 7.0, residual chlorine 1.0 mg/L; chloramine 25 ℃ 750, 5 ℃ 2 200, below 1 ℃ 3 800 mg·min/L.
- Health Canada, "Guidelines for Canadian Drinking Water Quality: Total Coliforms" technical document Table 5 (citing Hoff 1986, USEPA 1999): CT required for 5 ℃, 99% inactivation—free chlorine for E. coli 0.034 to 0.05, Giardia 65 to 93, viruses 4.0; monochloramine for E. coli 95 to 180, Giardia 1 470, viruses 857 mg·min/L.
- Zhang Min, Xu Ying, Miao Yi, et al., "Application of Chlorine Disinfection CT Values in Municipal Wastewater Treatment Plants and the Influence of Phosphorus Removal Chemicals," China Water & Wastewater, 2024, 40(17): 79-83 (Wuxi Municipal Public Environment Testing Research Institute, Wuxi Water Group): correlation coefficient between CT value and log removal of fecal coliform 0.8; recommended control of total residual chlorine in effluent at 0.5 mg/L, available chlorine 3 to 5 mg/L; iron content in phosphorus removal chemicals exceeding 3% will impair the disinfection effect of sodium hypochlorite.
- "Study on Influencing Factors of Sodium Hypochlorite Disinfection Effect in Municipal Wastewater Treatment Plants," China Water & Wastewater, 2021(1): at contact time 12 min and available chlorine dosage 3.67 mg/L, the log removal of fecal coliform reaches more than 2.5 lg, ORP 578 mV, total chlorine CT 7.6 mg·min/L, free chlorine CT 3.3 mg·min/L; recommendations include providing a buffer structure upstream of disinfection, strengthening sodium hypochlorite storage management, and dechlorinating fecal coliform water samples.
- "Study on Influencing Factors and Optimization of Sodium Hypochlorite Disinfection in Municipal Wastewater Treatment Plants" (reprinted by Guangxi Water Association): stable compliance can be achieved with contact time ≥10 min and available chlorine dosage 1 mg/L; a survey of wastewater treatment plants nationwide applying high discharge standards found an average available chlorine dosage of 3.69 mg/L and average residual chlorine of 1.12 mg/L; after optimization, residual chlorine was 0.02 to 0.16 mg/L at contact 30 min; ORP and ΔORP were proposed to characterize disinfection effect.
- "Intelligent dosing of sodium hypochlorite in municipal wastewater treatment plants: Experimental and modeling studies" (2024): the product of residual chlorine and contact time was used as the disinfection evaluation index; at a critical CT value of 0.20 mg·min/L, effluent fecal coliform was below 1.0×10³ MPN/L; LSTM feedforward plus CT feedback control, R² 0.948.
- Matamoros V., Mujeriego R., Bayona J. M., Trihalomethane occurrence in chlorinated reclaimed water at full-scale wastewater treatment plants in NE Spain, Water Research, 2007, 41(15): 3337-3344: total trihalomethanes 2 to 30 μg/L, at dosages of 2 to 5 and 16 mg/L Cl₂; formation was low under high ammonia nitrogen conditions (chloramine pathway, p<0.05), bromide 0 to 1 mg/L increased it, and UV irradiation had no statistically significant effect on formation or removal.
- Wang Guanghui, "Investigation and Optimization Recommendations on the Operation of UV Disinfection Processes in Municipal Wastewater Treatment Plants in China," China Water & Wastewater: the design irradiation residence time of each plant is basically 4 to 8 s; plant 2 uses CASS intermittent effluent without a buffer equalization tank, and the design flow was taken as the average flow, resulting in insufficient dose during peak periods; plant 6 has insufficient dose due to low lamp power; reduction factors were calculated using the default values 0.5 and 0.6 per GB/T 19837—2019.
- Hefei Wangxiaoying Wastewater Treatment Plant UV disinfection project (public information from Anlis Environmental Technology): capacity 29 万 m³/d, peak 12 083 m³/h; 540 low-pressure high-intensity lamps, single-lamp UV-C output ≥110 W; two open channels 25 m × 1.8 m × 1.5 m; fouling factor 0.8, aging factor 0.5, end-of-life dose ≥25 mJ/cm²; CFD-simulated worst-case point RED 28 mJ/cm². Manufacturer data, for engineering reference only.
Multi-industry nationwide (municipal and industrial park wastewater treatment pl
Small to very large (10,000 to 290,000 m³/d; contact tank 200 to 2,000 m³, UV ch