Water in Chlor-Alkali: Total Mercury of 3 μg Written at the Workshop Gate, the Water Stream Carries Only Four Ten-Thousandths
GB 15581—2016 lists 14 water pollutants for the caustic soda and polyvinyl chloride industries. Among them, 4 are not measured at the total outlet but at the workshop outlet, and none of these 4 values has been changed in the special emission limits. Multiplying 0.003 mg/L by the benchmark wastewater discharge volume of 5.0 m³/t, the water-borne mercury quota for a single calcium carbide process PVC plant is only 0.015 grams per ton of product—while the mercury it inputs is 35 to 180 grams.
I. First, lay out the standard: 14 items, two monitoring locations, three benchmark wastewater discharge volumes
GB 15581—2016 "Emission Standard of Pollutants for Caustic Soda and Polyvinyl Chloride Industry" was released on 2016 年 8 月 22 日 and implemented on 9 月 1 日; new enterprises shall comply from the implementation date, and existing enterprises shall comply from 2018 年 7 月 1 日. It replaces the standard of the same name from 1995 年, and this revision did four things at once: added air pollutant control requirements, adjusted water pollutant control items, tightened water pollutant limits, added special emission limits for water and air, and at the same time abolished tiered management by sewage destination.
There are 14 water pollutant items in total, but they are not laid out as a single flat table in the standard—viewing them separately by "conventional pollution" and "process characteristics" reveals the structure. First look at the 8 conventional items:
| Pollutant Item | Direct Discharge | Indirect Discharge | Remarks |
|---|---|---|---|
| pH Value | 6~9 | 6~9 | Same value in both columns |
| Chemical Oxygen Demand (CODCr) | 60 | 250 | Difference between the two columns: 4.2 times |
| Five-day Biochemical Oxygen Demand (BOD5) | 20 | 60 | Polyvinyl chloride enterprises only |
| Suspended Solids | 30 | 70 | Applicable to both types of enterprises |
| Petroleum | 3 | 10 | Applicable to both types of enterprises |
| Ammonia Nitrogen | 15 | 40 | Applicable to both types of enterprises |
| Total Nitrogen | 20 | 50 | Applicable to both types of enterprises |
| Total Phosphorus | 1.0 | 5.0 | Applicable to both types of enterprises |
Now look at the remaining 6 items. They share one thing in common: each row has only one value, with no distinction between direct discharge and indirect discharge columns.
| Pollutant Item | Controlled Pollution Source | Limit Value | Monitoring Location |
|---|---|---|---|
| Sulfide | Acetylene-based polyvinyl chloride enterprises | 0.5 | Enterprise wastewater main discharge outlet |
| Total Barium | Caustic soda enterprises | 5 | Enterprise wastewater main discharge outlet |
| Active Chlorine | Caustic soda enterprises | 0.5 | Workshop or production facility discharge outlet |
| Vinyl Chloride | Polyvinyl chloride enterprises | 0.5 | Workshop or production facility discharge outlet |
| Total Mercury | Acetylene-based polyvinyl chloride enterprises | 0.003 | Workshop or production facility discharge outlet |
| Total Nickel | Caustic soda enterprises | 0.05 | Workshop or production facility discharge outlet |
In Table 2, the monitoring location for the last four rows is stated as "Workshop or production facility discharge outlet," while the first three rows state "Enterprise wastewater main discharge outlet." These four rows are not a typesetting coincidence but represent four different types of management requirements: active chlorine, vinyl chloride, total mercury, and total nickel are all sampled at the workshop outlet and all have only one limit value.
Supporting these are three baseline wastewater discharge volumes: caustic soda enterprises 1.0 m³/t product, acetylene-based polyvinyl chloride enterprises 5.0 m³/t product, and ethylene oxychlorination-based polyvinyl chloride enterprises 2.0 m³/t product. Article 4.1.5 stipulates that when the actual wastewater discharge volume exceeds the baseline discharge volume, it must be converted into the baseline water volume discharge concentration according to the formula, and the converted value shall be used to determine compliance:
Cbaseline = Qtotal / Σ(Yi·Qi baseline) × Cactual
| Enterprise Type | Benchmark Discharge Volume (m³/t product) | Discharge Measurement Location |
|---|---|---|
| Caustic Soda Enterprises (mainly ion-exchange membrane process) | 1.0 | Same as the pollutant emission monitoring location |
| Acetylene Process (Calcium Carbide Process) Polyvinyl Chloride Enterprises | 5.0 | Same as the pollutant emission monitoring location |
| Ethylene Oxychlorination Process Polyvinyl Chloride Enterprises | 2.0 | Same as the pollutant emission monitoring location |
II. Four Workshop Outlet Indicators: None Relaxed for Indirect Discharge
The conclusion of this section is very brief, but it deserves a section of its own: In GB 15581—2016, "workshop or production facility discharge outlet" and "only one numerical value" appear simultaneously. Among the 14 indicators, the remaining 10 all provide two columns for direct discharge and indirect discharge (indirect discharge is generally relaxed by 2 to 4 times), while none of these 4 indicators is relaxed at all.
Combining these two characteristics is equivalent to simultaneously rejecting the two common fallback options on site:
- No dilution at the final outfall.The sampling point is at the workshop or production unit outlet; no amount of other water in the plant can mix in. This follows the same logic as GB 8978 for Class I pollutants (including total mercury), which requires sampling at the workshop outlet, except that here the scope is narrowed from 13 items to 4 items.
- No reliance on discharge to a sewage treatment plant.The indirect discharge column does not exist, meaning that when discharging to the industrial park wastewater treatment plant, these 4 items are still assessed against the same limit, and discharge to a treatment plant does not constitute grounds for relaxation.
III. From Table 1 to Table 2: 8 items tightened, 6 items unchanged
The standard also sets special emission limits for water pollutants (Table 2), applicable to areas with high land development density, weakened environmental carrying capacity, or small water environment capacity and fragile ecosystems; the scope and timing of implementation are prescribed by the Ministry of Ecology and Environment or the provincial people's government. Aligning the two tables item by item reveals a very clear dividing line:
| Pollutant Item | Table 1 (Direct Discharge / Indirect Discharge) | Table 2 (Direct Discharge / Indirect Discharge) | Tightening Factor |
|---|---|---|---|
| Chemical Oxygen Demand / COD | 60/250 | 40/60 | 1.5/4.2 |
| Five-Day Biochemical Oxygen Demand | 20/60 | 10/20 | 2/3 |
| Suspended Solids / SS | 30/70 | 20/30 | 1.5/2.3 |
| Petroleum Substances | 3/10 | 1/3 | 3/3.3 |
| Ammonia Nitrogen | 15/40 | 8/15 | 1.9/2.7 |
| Total Nitrogen / TN | 20/50 | 10/20 | 2/2.5 |
| Total Phosphorus / TP | 1.0/5.0 | 0.5/1.0 | 2/5 |
| Sulfides | 0.5/0.5 | 0.2/0.2 | 2.5 |
The 6 items that remain unchanged are: pH 6~9, Total Barium 5, Active Chlorine 0.5, Vinyl Chloride 0.5, Total Mercury 0.003, Total Nickel 0.05. It is understandable that pH remains unchanged; however, all the other 5 items retain their original values, including the fact that all conventional pollutants (all except Total Barium and Sulfides) have been tightened while Total Barium has not, and also including the fact that none of the 4 items at the workshop outlet has been changed.
IV. Among the 14 parameters, 6 are not about "the water being dirty" but about "what you used"
This is the most informative part of this standard. The 14 parameters all appear to be water quality indicators, but 6 of them have nothing to do with "how dirty the influent is"—they are only related to "what chemicals you added and what materials you used on this line." Understanding this correspondence table is more useful than memorizing the limit values.
| Indicator | Process Unit It Points To | Why It Enters the Water |
|---|---|---|
| Total Barium 5 mg/L | Brine Refining | Barium chloride is dosed to remove sulfate, forming barium sulfate precipitate; excess barium remains in the brine |
| Sulfide 0.5 mg/L | Acetylene Generation and Purification | Sulfur introduced with calcium carbide is converted to sulfide during acetylene generation and purification |
| Active Chlorine 0.5 mg/L | Chlorine-Hydrogen Handling, Sodium Hypochlorite Preparation, Chlorinated Cleaning | The chlor-alkali plant itself produces chlorine; free chlorine is discharged with process water and cleaning water |
| Vinyl Chloride 0.5 mg/L | Polymerization, Slurry Stripping, Centrifuge Mother Liquor | Residual and dissolved monomer in the aqueous phase |
| Total Mercury 0.003 mg/L | Mercuric Chloride Catalyst for Vinyl Chloride Synthesis | At a synthesis temperature of 120~180 ℃, part of the mercury sublimes and enters water washing and alkali washing with the gas, and is discharged when the alkali is replaced |
| Total Nickel 0.05 mg/L | Ion-Exchange Membrane Electrolysis and Nickel-Containing Materials | An indicator specific to caustic soda enterprises; the industry mostly points to nickel-based activated cathodes and nickel-containing components in electrolyzers (this is a process explanation, not the original standard text) |
The most typical is total barium. Raw salt inherently contains trace barium, but setting the limit at the 5 mg/L order of magnitude and listing a separate row specifically for caustic soda enterprises points not to raw salt, but to the barium chloride dosed by the ton in the brine refining step. The appearance of an indicator in a table often means that a chemical or a material in a certain process step is leaving its signature in the form of that indicator.
Conversely, from the indicator table of an industry emission standard, one can infer the industry's main processes. The chlor-alkali table is almost half a process flow diagram: electrolysis (active chlorine, total nickel), brine purification (total barium), acetylene and monomer synthesis (sulfides, vinyl chloride, total mercury).
V. Chloride: not among the 14 items, Article 4.1.4 delegates the authority to the province
An industry that uses sodium chloride as raw material and carries away large amounts of chloride ions per ton of product—yet chloride ions and total salt content are nowhere to be found among the 14 indicators of the national standard. The standard did not overlook them; it explicitly delegated them:
This arrangement shows one thing: the harm of chloride ions does not depend on the process, but on which water body they are discharged into. Discharged to the sea along the coast, into rivers inland, into lakes in the northwest—the same 3000 mg/L has completely different consequences in different places. Writing it uniformly into a fixed limit would instead erase the differences between the brine process and the refined salt process, and between coastal and inland areas.
There is another clue in the revision history of the same standard: the 1995 年 version listed asbestos, and the 2016 年 version removed it. The removal does not mean it is no longer regulated, but rather that the asbestos diaphragm process route itself is being phased out—an industry's characteristic pollutants will disappear from the standard as process routes are replaced. This is the same orientation as the 2016 version's overall removal of "tiered management according to sewage destination": regulate the process, not the destination.
VI. Mercury: 0.015 grams is the unit's entire annual water-pathway quota
Now we can do that decisive division. Total mercury limit 0.003 mg/L, benchmark discharge volume for acetylene-based polyvinyl chloride 5.0 m³/t:
0.003 mg/L × 5 000 L/t = 15 mg/t = 0.015 g/t product
This is all the mercury the standard allows to leave with the water. Note that the benchmark discharge volume is used here rather than the actual discharge volume—according to Article 4.1.5, exceeding the benchmark requires conversion and scaling up, so 0.015 g/t is the quota when "discharge volume is controlled within 5.0 m³/t", and is the upper limit that can be obtained.
Now look at the input side. The compliance requirement is that by 2020 年, the mercury consumption per unit product of calcium carbide-based polyvinyl chloride be reduced by 50% relative to the 2010 年 baseline, and the assessment rules issued in 2019 年 translate this target into 49.14 g/t polyvinyl chloride, with a requirement for sustained stable and gradual reduction. Comparing the two sides:
0.015 ÷ 49.14 = 3.05 per ten thousand; if calculated based on the 35 g/t already achieved by a certain enterprise, 0.015 ÷ 35 = 4.3 per ten thousand
| Caliber | Unit Catalyst Consumption | Mercury Content of Catalyst | Mercury Input (g/t) | Water Pathway Share |
|---|---|---|---|---|
| High-mercury catalyst period (around 2010 年) | Approx. 1.2 kg/t | 12.5% | Approx. 150 | One ten-thousandth |
| Before low-mercury substitution (a leading enterprise, 2013 年) | 1.456 kg/t | 12.5% | Approx. 182 | 0.8 ten-thousandths |
| After low-mercury substitution (same enterprise) | 0.6 kg/t | 6.5% | Approx. 39 | 3.8 ten-thousandths |
| Compliance target value | — | — | 49.14 | 3.1 ten-thousandths |
| Multi-component composite catalyst system (current status of an enterprise) | Approx. 1.4 kg/t | Below 2.5% | Approx. 35 | 4.3 ten-thousandths |
This multiplication chain also yields a criterion: mercury consumption is the product of "catalyst unit consumption × mercury content"; reporting only total mercury consumption cannot determine whether it relies on using less catalyst or on diluting the catalyst. The engineering implications of these two things are completely different—the former requires changing the catalytic system (mercury-free or multi-component composite catalysts), while the latter only requires changing the impregnation concentration, and the latter will make the mercury in spent catalyst more dispersed and harder to recover, while shifting the risk from "usage amount" to "loss rate". The national standard for low-mercury catalysts imposes dual requirements on mercury content (4%~6.5%) and mercury loss rate (not greater than 3%), precisely to block this path. Counterfeit and inferior low-mercury catalysts with mercuric chloride content of 7%~9% once appeared on the market; some enterprises had catalyst unit consumption exceeding 2 kg/t, nominally low-mercury while actual mercury consumption was higher than that of qualified low-mercury catalysts.
The figure 35 g/t in Table 6 can also be decomposed another way: 1.40 kg/t × 2.5% also gives 35 g/t, and 1.40 kg/t happens to be the catalyst consumption upper limit for the level-3 tier of the calcium carbide process polyvinyl chloride given by the cleaner production standard (HJ 476—2009). The same result can be achieved by two different paths, which is exactly what "reporting only the total without reporting the factors" conceals.
七、含汞废水:三级台阶,两道算术
Mercury-containing wastewater has a very small volume, non-low concentration, and large fluctuations. Public engineering data give influent concentrations on the order of 0.3 to 1 mg/L: for one calcium carbide process PVC plant, the spent alkali liquor from the alkali washing tower, part of the acidic wastewater, and condenser drainage after mixing are about 1 mg/L; for another plant, the equipment and floor washing water, initial rainwater, and wastewater generated from replacing spent catalyst are about 0.3 mg/L. To press 1 mg/L down to 0.003 mg/L, the removal rate is 99.7%.
In engineering terms this is a three-stage staircase, each stage solving a different problem:
- First stage, chemical precipitation. After pH adjustment, sodium sulfide or sodium hydrosulfide is dosed to form mercury sulfide, then flocculant is added to form large flocs. Typical conditions given in public materials are pH 9~11, sodium sulfide dosage 5~20 times the theoretical amount, with 0.01%~0.03% inorganic flocculant, and the effluent from this stage reaches about 0.05 mg/L.
- Second stage, solid-liquid separation. Sedimentation plus membrane filtration (continuous membrane filtration, TMF), or precoat with filter aid plus plate-and-frame filter pressing. This step does not change the chemical equilibrium; it only intercepts the already-formed mercury sulfide particles—fine particle breakthrough is the most common failure mode at this stage.
- Third stage, deep adsorption. Activated carbon or dedicated mercury removal adsorbent presses residual mercury below 0.003 mg/L. One enterprise used a dedicated adsorbent 2011 年 and put it into operation, with effluent stably below 0.003 mg/L; another enterprise used "acid-controlled sulfidation + fractional-loading adsorption" to achieve 0.00106~0.00110 mg/L.
| Route | Key Conditions | Effluent Total Mercury | Source |
|---|---|---|---|
| Neutralization + Sodium Sulfide + PAM + Sedimentation + Continuous Membrane Filtration + Activated Carbon | Influent approx. 1 mg/L; pH 6.0~7.0; trace vinyl chloride first stripped by aeration | Meets standard for reuse | A chlor-alkali enterprise in Ningxia |
| Neutralization + Sodium Hydrosulfide + Filter Aid + Plate-and-Frame Filter Press + Activated Carbon Filtration | Influent 0.3 mg/L; pH 7~10 | Below 0.003 | A chlor-alkali wastewater comprehensive utilization facility |
| Two-stage Sodium Sulfide + Aluminum Chloride Co-precipitation + Retrofitting | pH 9.0~10.0; originally flocculation sedimentation + zinc particle bed, effluent 0.005 | Reaches 0.003 after retrofitting | A chemical enterprise in Tianjin |
| Dedicated Mercury Removal Adsorbent Bed | pH adjusted to neutral; precipitation and filtration first to reduce suspended solids; adsorbent regenerable | Below 0.003 | A group in Xinjiang, commissioned in 2011 年 |
VIII. Four pH Ranges: 6.0, 7~10, 9.0~10.0, 9~11
The operating pH given by the four public sources differs by 5 pH units. This is not a case of someone copying it wrong; it is that the four processes co-precipitate by drawing on different things.
| pH Range | Process Characteristics | What pH Controls |
|---|---|---|
| 6.0~7.0 | Sodium Sulfide + PAM + Continuous Membrane Filtration | Precipitation relies on membrane interception as a fallback; pH only serves flocculation and Membrane Flux |
| 7~10 | Sodium Hydrosulfide + Filter Aid + Plate and Frame | Same as above, interception by filter aid layer, pH range relaxed |
| 9.0~10.0 | Sodium Sulfide + Aluminum Chloride Co-precipitation | pH follows the formation zone of Al(OH)3 colloids; mercury co-precipitates via flocs |
| 9~11 | General Conditions for Chemical Precipitation | Balances sulfide dissociation and hydroxide co-precipitation |
Mercury sulfide has an extremely small solubility product and theoretically is not pH-selective. In engineering practice, pH controls two other things: first, the chloro-complex speciation of mercury. Mercuric chloride has high solubility at room temperature (about 78 kg soluble per cubic meter of water); at high chloride ion concentrations, mercury exists stably as chloro-complex ions, and the precipitant must first break it apart; second, the precipitation carrier. At pH 9~10, aluminum salts form aluminum hydroxide colloids, and fine mercury sulfide particles co-precipitate with them; at this point pH must follow the flocculant rather than the solubility product. Conversely, when pH is too high, sulfide ions hydrolyze to hydrogen sulfide and escape, which both wastes chemicals and creates odor and poisoning risks—this is the real reason for the upper pH limit.
IX. Salt Mud and Carbide Slag: Moisture Content Is the Factor Not in the Table
The hardest part of chlor-alkali water lies in solid waste. Salt mud is a mixture of precipitates and mechanical impurities produced during raw salt refining (adding sodium carbonate, sodium hydroxide, and barium chloride to remove calcium, magnesium, and sulfate), with public data showing: when refined salt is used, salt mud (dry basis) per ton of caustic soda is 10~25 kg, and when raw salt has more impurities, 50~60 kg; calculated by sea salt, about 30 kg/t, and by rock salt and lake salt, 50~60 kg/t. 2006 年National caustic soda output is 1 511 万 t, with salt mud about 60 万 t, equivalent to 39.7 kg/t—higher than "sea salt 30 kg/t" by 32%, indicating that the national average raw salt impurity level is higher than the sea salt basis.
| Item | Generation Rate | Moisture Content and Form | Disposal |
|---|---|---|---|
| Salt Mud (Sea Salt) | Approx. 30 kg/t alkali (dry basis) | Moisture 85%~90%, filter cake after plate-and-frame filter pressing approx. 30% | Recovery of barium sulfate, building materials, landfill |
| Salt Mud (Rock Salt, Lake Salt) | 50~60 kg/t alkali (dry basis) | Same as above, converted volume 0.3~0.9 m³/t | Same as above |
| Mercury-Containing Salt Mud (Mercury Process, Historical) | Mercury loss per ton of alkali 150~200 g | Mercury process has been phased out | For reference only in legacy site investigation |
| Carbide Slag (Acetylene Process PVC) | 1.60~1.70 t/t (dry basis, Cleaner Production Level 3) | Slurry form from wet acetylene process; moisture 4%~10% from dry acetylene process | Cement production, brick making, supernatant 100% reuse |
| Mercury-Containing Sludge (Wastewater Treatment) | Depends on treatment volume, formed into cake after filter pressing | Contains mercury sulfide | Disposed of as hazardous waste by qualified entities |
There are two sets of publicly available figures for the composition of salt mud: the Cleaner Production Standard drafting notes give barium sulfate 35%~45%, calcium and magnesium carbonates approx. 25%, sodium chloride 2%~2.5%; a resource utilization review gives calcium carbonate 15%~40%, magnesium hydroxide 8.5%~30%, sodium chloride 7%~13%. The discrepancy is considerable, and the reason lies in the different compositions of raw salt and brine across regions. These two sets of figures cannot be used interchangeably, nor can they be averaged.
10. Benchmark Discharge Volume: 5.0 m³/t implies a reuse rate of 85.7%
The conversion formula in Article 4.1.5 means that the benchmark discharge volume is not "how much may be discharged," but "at what water volume the concentration is recognized." The larger the actual discharge volume, the higher the converted concentration. Putting this rule together with the reuse rate requirements of the cleaner production standard yields a number that does not appear in the standard text.
Taking acetylene-based polyvinyl chloride as an example, the cleaner production standard (HJ 476—2009) Tier 3 level specifies: wastewater generation per unit product no greater than 40 m³/t, and wastewater reuse rate no less than 75%. At 75% reuse, the discharge volume is 10 m³/t, which is 2 times the benchmark 5.0, with a conversion factor of 2—the measured COD must be pressed down to 30 mg/L to meet the standard, while the limit in Table 1 is stated as 60. Conversely, to press the conversion factor down to 1.0, the reuse rate must reach 85.7%.
| Wastewater Reuse Rate | Actual Discharge Volume (m³/t) | Conversion Factor | Measured COD Must Not Exceed |
|---|---|---|---|
| 75% (Tier-3 lower limit) | 8.75 | 1.75 | 34.3 |
| 80% (Tier 2) | 7.00 | 1.40 | 42.9 |
| 85.7% | 5.00 | 1.00 | 60.0 |
| 90% (Tier 1) | 3.50 | 0.70 (determined by measured value) | 60.0, margin 1.43 times |
| 90% (Tier 1) + generation 12 m³/t | 1.20 | 0.24 (determined by measured value) | 60.0, margin 4.17 times |
There is another point that is easily miscalculated: the fresh water consumption given by HJ 476 Level 1 is no more than 9.0 t/t, while the wastewater generation is no more than 12 m³/t, the latter being greater than the former. The two are not contradictory—the generation volume counts all water entering the drainage system (including reused water and circulating blowdown), while the intake volume only counts external fresh water. "Intake" and "generation" are two different accounting bases; they cannot be subtracted, nor can they be added.
XI. Several Things That Truly Require Attention in Engineering
- The workshop outlet is a single pipeline, not a single process. Total mercury 0.003 mg/L sampled at the workshop or production unit outlet means that mercury-containing wastewater must be collected separately by quality. Equipment and floor wash water, initial rainwater, and wash water from catalyst replacement all enter this line; mixing them into the plant-wide pipe network is equivalent to giving up the possibility of compliance on your own.
- 0.003 mg/L is already close to the routine working lower limit of the method. At this magnitude, vessels, reagent blanks, and the memory effect of mercury directly determine the reported value. The same bottle of water in a different container may give a different number—the importance of sampling and preservation protocols is no less than that of the mercury removal process itself.
- The success or failure of mercury removal often lies in pretreatment. If Suspended Solids / SS are not reduced, fine mercury sulfide particles will pass through the filter; if organic matter is not reduced, Activated Carbon will first be occupied by organic matter, and the adsorption capacity will not reach the mercury. In public cases, actions such as "first aerating to strip trace vinyl chloride" and "first using a filter aid to form a filter layer" all serve the subsequent two stages.
- The three destinations must be calculated together. Spent catalyst (mercury-containing hazardous waste), mercury-containing sludge (filter-pressed and handed over to a qualified unit), and wastewater. The water pathway bears only 4 in 10,000, and the remaining 99.96% of mercury is in solid waste and exhaust gas. Making the mercury removal unit极致 alone is equivalent to finely treating 4 in 10,000 while handing 99.96% to others.
- Low mercury does not equal low risk. Judgment can only be made by looking at the two factors "unit consumption × mercury content" together, plus the mercury loss rate. Looking only at the catalyst name or only at the mercury content may be bypassed by products that are nominally low-mercury but actually high-consumption.
XII. Conclusion
The water in chlor-alkali appears on the surface to be a heavy metal compliance issue, but in reality it is a material balance problem. The number 0.003 mg/L itself is not stringent; what is stringent is where it appears—the workshop outlet—and the absence of a second column for indirect discharge. When the sampling point is moved to the workshop, and when the limit is multiplied by the benchmark discharge volume to become 0.015 g/t, the destination of mercury is locked: 99.96% must go through solid waste and recovery, and the water pathway has no margin to squeeze.
This also explains why the treatment path for this industry is "reduce the source first, then treat the end": low-mercury and multi-component composite catalysts reduce 150 g/t to 35 g/t, so that the burden of the three end-of-pipe stages changes from "impossible" to "difficult"; and if the source is not changed and money is spent only on adsorption columns, no matter how good the adsorbent is, the total amount of mercury coming in remains there.
As for the item not in the standard—chloride and total salt content—Article 4.1.4 delegates it to local authorities, meaning that the next round of constraints for this industry will not come from the national standard, but from the water body into which it discharges. For technical personnel, this is more worth looking at in advance than any limit value.
References
- GB 15581—2016 "Emission Standard of Pollutants for Caustic Soda and Polyvinyl Chloride Industries" (released version), issued by the Ministry of Environmental Protection and the General Administration of Quality Supervision, Inspection and Quarantine on 2016-08-22, implemented on 2016-09-01. Table 1 Water Pollutant Emission Limits, Table 2 Special Emission Limits for Water Pollutants, Articles 4.1.1~4.1.5, Benchmark Effluent Volume per Unit Product. https://www.mee.gov.cn/ywgz/fgbz/bz/bzwb/dqhjbh/dqgdwrywrwpfbz/201608/W020160830365171931763.pdf
- Ministry of Ecology and Environment, "Interpretation of the 'Emission Standard of Pollutants for Caustic Soda and Polyvinyl Chloride Industries'", 2016-08-30. Annual emissions of COD, BOD5, total mercury, and vinyl chloride are reduced by 77%, 67%, 67%, and 87%, respectively; total investment in wastewater treatment facilities is approximately 22 亿 yuan, and annual operating cost of 4 亿 yuan accounts for about 0.8% of production cost. https://www.mee.gov.cn/zcwj/zcjd/201608/t20160830_363311.shtml
- HJ 476—2009 "Cleaner Production Standard Chlor-Alkali Industry (Calcium Carbide Process Polyvinyl Chloride)" Table 1: calcium carbide consumption per unit product 1 400/1 420/1 450 kg/t, fresh water consumption 9.0/10.5/12.0 t/t, mercury catalyst consumption 1.20/1.30/1.40 kg/t, wastewater generation 12/35/40 m³/t, total mercury generation in wastewater 1.5/1.8/2.0 g/t, calcium carbide slag generation (dry basis) 1.60/1.65/1.70 t/t, wastewater reuse rate 90%/80%/75%, calcium carbide slag slurry supernatant reuse rate 100%.
- "Cleaner Production Standard Chlor-Alkali Industry (Caustic Soda)" Preparation Notes, Ministry of Ecology and Environment: sea salt produces salt mud of 30 kg per ton of caustic soda, rock salt and lake salt 50~60 kg; in 2006 年, national caustic soda 1 511 万 t, salt mud 60 万 t; main components of salt mud are barium sulfate 35%~45%, calcium and magnesium carbonates 25%, sodium chloride 2%~2.5%. https://www.mee.gov.cn/gkml/hbb/bgth/200910/W020081105585763123096.pdf
- "Feasibility Study on Application of Salt Mud in Brine Drilling Fluid": during refined salt production, salt mud (dry basis) 10~25 kg/t, 50~60 kg/t when impurities are high, converted volume 0.3~0.9 m³/t, moisture content 85%~90%, filter cake moisture after plate-and-frame filter pressing about 30%; dry basis composition Mg(OH)2 8.5%~30%, CaCO3 15%~40%, NaCl 7%~13%. https://www.syzt.com.cn/cn/article/pdf/preview/10.pdf
- Zhuo Yunhong, Wang Shihe, "Resource Utilization of Chlor-Alkali Salt Mud", China Sciencepaper Online: each ton of caustic soda produces on average 30~60 kg of salt mud, whose dry basis is mainly calcium carbonate, magnesium hydroxide, barium sulfate and mechanical impurities. https://www.paper.edu.cn/releasepaper/downFile/original/MUzGMFwQNRjVMIeQeQ
- Science Popularization China · Salt Mud: in the mercury process for caustic soda, mercury lost through precipitation in salt mud is about 150~200 g per ton of alkali; mercury-process salt mud contains about 100 mg/kg of mercury after treatment by the oxidative dissolution method. https://www.kepuchina.cn/article/articleinfo?business_type=100&ar_id=296098
- Ministry of Ecology and Environment, "Implementing the Mercury Convention and Writing a New Chapter in Chemicals Environmental Management", 2017-08-16: the "13th Five-Year Plan for Ecological and Environmental Protection" requires prohibiting the construction of new calcium carbide process polyvinyl chloride production projects using mercury-containing processes, and by 2020 年, the mercury consumption per unit product in the polyvinyl chloride industry is to be reduced by 50% relative to the 2010 年 level.
- Ministry of Ecology and Environment, "Speech at the Exchange Meeting on the First Anniversary of the Entry into Force of the Minamata Convention on Mercury and China's Implementation Progress", 2018-09-03: it is once again clarified that by 2020 年, the mercury consumption per unit product of calcium carbide process polyvinyl chloride is to be reduced by 50% compared with 2010 年. https://www.mee.gov.cn/xxgk2018/xxgk/xxgk15/201809/t20180903_630501.html
- Ministry of Ecology and Environment, "Answers to Reporters' Questions on the 'Opinions on Strengthening Pollution Prevention and Control in Heavy Metal-Related Industries'", 2019-04-10: calcium carbide process polyvinyl chloride enterprises need to formulate and implement a plan to halve mercury use intensity; those that have already implemented low-mercury catalyst substitution and reached the halving target no longer need to formulate a separate plan. https://www.mee.gov.cn/ywgz/gtfwyhxpgl/zjshjgl/201904/t20190410_699161.shtml
- Ministry of Ecology and Environment, Reply to Recommendation No. 1310 of the Third Session of the 14th National People's Congress: 2019 年, together with the Ministry of Industry and Information Technology, issued assessment rules to ensure that the industry achieves the compliance target of no more than 49.14 grams of mercury per ton of polyvinyl chloride; the "Catalogue for Guidance of Industrial Structure Adjustment" lists high-mercury catalysts with a mercuric chloride content above 6.5% and acetylene process polyvinyl chloride plants using high-mercury catalysts as elimination category. https://www.mee.gov.cn/xxgk2018/xxgk/xxgk13/202511/t20251117_1133976.html
- China Industry News, "Remarkable Results in Mercury Reduction and Emission Reduction in the Calcium Carbide Process Polyvinyl Chloride Industry", 2018-04-27: one enterprise's 110 万 t plant has been fully converted to low-mercury catalysts, reducing annual mercury use by 70 t; another enterprise's 150 万 t/a facility fully applies low-mercury catalysts, with catalyst consumption per ton of PVC of 1 kg, 0.375 kg lower than 2013 年, saving 3 942.7 万 yuan annually; counterfeit and inferior low-mercury catalysts have a mercuric chloride content of 7%~9%, and catalyst consumption in some enterprises exceeds 2 kg/t; the "High-Risk Pollutant Reduction Action Plan" reward standard is mercury in workshop wastewater not exceeding 3 micrograms/liter and mercury-containing wastewater discharge not exceeding 0.05 m³/t. https://www.cinn.cn/hg/2018/04-27/PDAjPKyk.html
- BJX Environmental Protection Network, "Minamata Convention 8 月 16 日 Enters into Force, All-Out Battle on Mercury Limitation in Chlor-Alkali Enterprises Begins", 2017-08-17: low-mercury catalyst refers to a mercury catalyst with a mercury content of 4%~6.5%, a mercury loss rate of no more than 3%, and conforming to GB/T 31530—2015; high-mercury catalyst has a loss rate greater than 73%; one enterprise's catalyst consumption dropped from 1.456 kg/t to 0.6 kg/t, with mercury consumption reduced by about 78%. https://mhuanbao.bjx.com.cn/mnews/20170817/844064.shtml
- Inner Mongolia News Network, "Solving the 'Mercury' Problem of the Chlor-Alkali Industry", 2025-10-16: one enterprise's mercury consumption in PVC production dropped from 150 grams per ton to 35 grams per ton; traditional catalyst contains 12.5% mercury, while the multi-component composite catalyst system has a mercury content below 2.5%; after treatment, wastewater mercury content is 0.00106~0.00110 mg/L, lower than the national standard of 0.003 mg/L; measured average flue gas mercury is 0.0072 mg/m³. https://inews.nmgnews.com.cn/system/2025/10/16/030243662.shtml
- "Treatment Technology for Mercury-Containing Wastewater from Vinyl Chloride", Wastewater Treatment Engineering Network: one enterprise has two calcium carbide process PVC plants; after mixing, the mercury-containing wastewater has about 1 mg/L mercury; vinyl chloride traces are stripped by aeration, pH is adjusted to 6.0~7.0, sodium sulfide, additives and PAM are dosed, after sedimentation the water passes through continuous membrane filtration (TMF), and the produced water is reused after activated carbon adsorption; the mercury-containing sludge is filter-pressed and handed to a qualified unit for disposal. https://www.dowater.com/jishu/2023-09-04/4254259.html
- "Comprehensive Utilization Process for Chlor-Alkali Production Wastewater", Wastewater Treatment Engineering Network: the main pollutant in mercury-containing wastewater is mercury 0.3 mg/L; sodium hydrosulfide is used for mercury removal, followed by flocculation sedimentation and activated carbon filtration adsorption; after treatment, mercury is less than 0.003 mg/L, and the effluent is used for the acetylene plant or brine extraction; reaction pH 7~10. https://www.dowater.com/jishu/2022-01-19/2228371.html
- "Mercury-Containing Wastewater Treatment Process for Calcium Carbide Process PVC Enterprises", Journal Network: the chemical precipitation method adjusts pH to 9~11, sodium sulfide dosage is 5~20 times the theoretical amount, and 0.01%~0.03% inorganic flocculant is added, which can reduce mercury to below 0.05 mg/L; activated carbon adsorption must be connected in series; dedicated adsorbents can reduce mercury to below 0.003 mg/L. https://www.chinaqikan.com/thesis/view/6978744
- "Mercury Wastewater Treatment by Filter Press": a chemical enterprise originally used flocculation sedimentation and a zinc particle bed for deep reaction, with effluent 0.005 mg/L; after the new standard required 0.003 mg/L, it was retrofitted to two-stage sodium sulfide reaction plus aluminum chloride co-precipitation, with operating pH 9.0~10.0; mercuric chloride can dissolve about 78 kg per cubic meter of water at room temperature. https://www.xiaoxianmi.cn/7043.html
- GB 8978—1996 "Integrated Wastewater Discharge Standard" Article 4.2.1.1: Class I pollutants (including total mercury) are sampled at the workshop or workshop treatment facility discharge outlet. Used to explain the relationship between workshop outlet sampling and total outlet dilution.
- GB/T 31530—2015 "Low-Mercury Catalyst for Vinyl Chloride Synthesis": low-mercury catalyst has a mercury content of 4%~6.5% and a mercury loss rate of no more than 3% (quoted from reference 13; the full text of the standard was not directly obtained).
The standard limits, monitoring locations, benchmark effluent volumes and conversion formulas in this article are all quoted from the original released version of GB 15581—2016; the tightening multiples and conversion coefficients of Table 4, Table 6, and Table 10, the water pathway quota of 0.015 g/t, the two ratios of 16.7 times and 3.3 times, and the proportions from 0.8 to 4.3 per ten thousand are all self-calculated based on public data; the calculation formulas are listed in the main text and can be reviewed item by item. The correspondence between total nickel and ion-exchange membrane electrolyzer materials in Table 5 is a process interpretation, not the original wording of the standard; please note the distinction when citing. There are two sets of public figures for salt mud composition; the difference stems from different compositions of raw salt and brine. This article lists both sets in parallel without averaging them. The three field cases come respectively from publicly available enterprise technical articles and news reports; they are enterprise self-accounts, have not undergone peer review, and serve only as order-of-magnitude references. No undisclosed monitoring data are used in this article.
Nationwide across multiple industries (chlor-alkali, calcium carbide process PVC
Engineering (mercury-containing wastewater 10 to 120 m³/h; caustic soda 100,000