Cases
Cases
Cases

At the plant boundary: hydrogen sulfide outside the wall must not exceed 0.06, which is 1/167 of the workshop limit.

Nationwide multi-industry coverage (municipal wastewater treatment plants, centr
Pilot to full-scale engineering (hundreds to 140,000 m³/d; plant boundary ammoni

Plant Boundary: Hydrogen Sulfide Outside the Wall Is Allowed Only 0.06, Which Is 1/167 of the Workshop Limit

The previous article discussed anaerobic reactors, where what gets swapped out is the "volumetric loading rate"; this article discusses the plant boundary, where what gets swapped out is the "monitoring point" and the "background." The same person, with the same breath, standing beside the tank measures 10 mg/m³ and that counts as normal, while standing outside the wall measures 0.06 mg/m³ and only that counts as compliant—a 167-fold difference between the two. And on the outside of the wall, three other numbers sit side by side: odor concentration 20 (dimensionless), methane 1% (volume fraction), and noise 60 dB(A). One table holds five dimensions, three standards specify three sets of monitoring points, and on the noise side there remains a loophole whereby "after background subtraction it may actually be judged compliant." Looking at five actual acceptance reports, the margin for ammonia ranges from 4 to 8 times, hydrogen sulfide from 1.3 to 15 times, while odor concentration at its tightest already reaches 90% of the limit; on the noise side, the margin can range all the way from 0 dB to 21 dB, entirely depending on how noisy it originally was outside the wall.

Gaowutong · Industrial Water Treatment Technology Series · For industry technical personnel · All data are annotated with sources from public standard clauses and acceptance reports

First, three numbers all written under the two words "plant boundary." In workshop air, the maximum allowable concentration of hydrogen sulfide is 10 mg/m³ (GBZ 2.1); at the plant boundary, the same hydrogen sulfide is permitted only 0.06 mg/m³ (GB 14554 and GB 18918 Table 4)—one inside the wall, one outside the wall, a 166.7-fold difference. At the plant boundary there is also odor concentration, with a limit of 20, dimensionless, whose corresponding olfactory sensation is "a very weak odor can be slightly perceived"—in other words, the standard allows you to smell it outside the wall. On the noise side it is 60 dB(A), but HJ 706 allows you to subtract the background first: for a plant boundary measured at 64 dB, if the background is 62 dB, it can be judged "compliant"; if the background is 55 dB, after correction it is 63 dB, exceeding the limit by 3 dB. The same equipment, the same 64 dB, two conclusions.

I. The same breath, a 167-fold difference inside and outside the wall

The plant boundary is not a geographical concept; it is a line of responsibility. Inside the line is the workplace, governed by the "Occupational Exposure Limits for Hazardous Agents in the Workplace"; outside the line is the environment, governed by emission standards. The two lines use the same batch of substances, but the objects of protection differ: inside the line it is "adults who stay here eight hours a day, whether they wear masks or not"; outside the line it is "elderly people and children who live next door twenty-four hours a day."

Table 1 Three limit values for the same substance, falling at three positions (unit: mg/m³)
SubstanceWorkshop Limit (GBZ 2.1)Plant Boundary Limit (GB 14554 Class II)Ratio
Hydrogen Sulfide10 (Maximum Allowable Concentration, MAC)0.06166.7
Ammonia20 (Time-Weighted Average, PC-TWA) / 30 (Short-Term Exposure, PC-STEL)1.513.3 / 20.0

The two ratios differ greatly: ammonia is only a dozen or so times, while hydrogen sulfide is over one hundred and sixty times. This is not an error in the standards, but a difference in the slopes of the two toxicity curves — hydrogen sulfide at high concentrations is an acute toxicant that "knocks you down with a single breath" (hence the workshop uses the Maximum Allowable Concentration, not to be exceeded for even a second), while at low concentrations it is an odorous substance that is "unpleasant to smell over the long term" (hence the plant boundary uses the single maximum monitored value to cap the peak). Ammonia is the opposite: its acute toxicity is weak, and its irritancy accumulates with concentration, which is why the workshop uses a time-weighted average.

This difference has a direct consequence: the same set of deodorization facilities has a different margin for ammonia than for hydrogen sulfide. In the five cases in Section 10, ammonia generally accounts for only 11% to 25% of the limit, while hydrogen sulfide ranges all the way from 6.7% to 77%. It is not that hydrogen sulfide is removed poorly, but that its limit is set low.

II. Five dimensions lie within a single table

The title of Table 4 in the "Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant" is "Maximum Allowable Concentration of Waste Gas Emissions at the Plant Boundary (Edge of the Buffer Zone)", but this title only holds true for the first two rows. The four rows cover four different things:

Table 2 GB 18918—2002 Table 4: four rows, four sets of dimensions, two monitoring locations
Control ItemLevel 1Level 2Level 3DimensionMonitoring Location
Ammonia1.01.54.0mg/m³Plant boundary (edge of buffer zone)
Hydrogen Sulfide0.030.060.32mg/m³Plant boundary (edge of buffer zone)
Odor Concentration102060DimensionlessPlant boundary (edge of buffer zone)
Methane0.512Volume percentage %Maximum within plant area

The first three rows are about "what is smelled outside the fence"; the fourth row is about "whether it will explode inside the plant". The parentheses in the methane row state "maximum volume concentration within the plant area"; the measurement point is inside the plant area, and it governs explosion protection, not odor control. Its dimension is volume percentage—1% corresponds to 10000 ppm, which converts to a mass concentration of 7143 mg/m³. Place this number side by side with the 0.06 for hydrogen sulfide in the same table, and the difference is 11.9 万 times. This multiple is meaningless, because the two are simply not in the same coordinate system: one is "how much volume in the air determines whether it will ignite", and the other is "how many micrograms in the air determines whether it will smell".

However, converting methane to a volume percentage has one use: it is tied to the lower explosive limit. The lower explosive limit of methane is 5% (by volume), so 1% is 20% LEL—the intent of the standard is that "combustible gas at any point in the plant area shall not exceed one-fifth of the lower explosive limit." In the acceptance monitoring of 2017 年 at the Jinjiang Xianshi Wastewater Treatment Plant, the maximum values at the two methane monitoring points in the plant area were 8.6×10⁻⁵%, equivalent to 0.86 ppm and 0.61 mg/m³, which is 1/11628 of the limit. This margin is so large that it does not look like "good treatment," but rather because methane simply cannot accumulate in open structures—it is only meaningful in enclosed sludge silos, digester tops, and the gas collection spaces of covered tanks.

A takeaway convention: When you see "methane 1%," do not put it in the same table as "hydrogen sulfide 0.06" to compare magnitudes. The former is a volume fraction, inside the plant area, for explosion protection; the latter is a mass concentration, at the plant boundary, for odor control. Different systems in the same table is the place in this standard most easily copied incorrectly—many self-prepared monitoring plans place methane monitoring points on the perimeter wall.

III. Odor Concentration 20: The Standard Allows You to "Just Smell It"

Odor concentration is the only one of these four indicators without a unit, because it is a dilution factor: the odor is diluted with odorless air until the panelists can just barely no longer smell it, and that factor is the odor concentration. The measurement follows the three-point comparison odor bag method, with a panel of six people; each person has their own olfactory threshold, and the collective result is taken.

Table 3 Correspondence Between Odor Intensity and Odor Concentration, and the Placement of Each Standard Tier
Odor Intensity (level)Odor Concentration (dimensionless)Olfactory PerceptionCorresponding Standard Tier
010OdorlessGB 18918 Class I / GB 14554 Class I (equal to the method's minimum detection value)
120A very faint odor can be slightly perceived, seemingly present yet absentGB 18918 Class II / GB 14554 Class II
251The type of odor can be identified——
3117Odor is clearly smelled——
4265Strong odor——
5600Strong malodor, causing nausea, vomiting, and headache——

The most important row to look at in this table is the second one: the 20 of the Class II standard falls exactly in the "just barely perceptible" tier. So the complete meaning of the statement "the odor concentration at the plant boundary is 18, meeting the standard" is "standing outside the wall, a slight odor can be smelled, but not yet enough to identify what it is." It does not promise "no odor can be smelled." Only the 10 of the Class I standard is odorless, and 10 is simultaneously the minimum detection value of the triangle odor bag method—the Class I standard actually means "not detectable."

This also explains a common mismatch in the field: residents complain about "odor," while monitoring reports show "compliance"—neither side is wrong. Because the standard governs the dilution factor at the fence line, whereas what a person smells standing on their own balcony is the combined result of wind direction, eddies, and instantaneous emission peaks. Article 5.1 of GB 14554 specifically states "single maximum monitored value"—it already acknowledges that peaks are the problem, but limits the peak to the fence line.

IV. Two nearly identical tables, differing in six items

The boundary odor of a wastewater treatment plant is actually governed simultaneously by two standards: Table 4 of GB 18918 (industry standard) and Table 1 of GB 14554 (general standard). Placing the two tables side by side reveals that they look as if struck from the same mold:

Table 4 Comparison of plant boundary values between Table 4 of GB 18918 and Table 1 of GB 14554 (mg/m³, odor concentration dimensionless)
ItemGB 18918 Class IGB 18918 Class IIGB 14554 Class IGB 14554 Class II (new/expanded/modified)GB 14554 Class II (existing)
Ammonia1.01.51.01.52.0
Hydrogen Sulfide0.030.060.030.060.10
Odor Concentration1020102030
Trimethylamine————0.050.080.15
Methyl Mercaptan————0.0040.0070.010
Dimethyl Sulfide————0.030.070.15
Dimethyl Disulfide————0.030.060.13
Carbon Disulfide————2.03.05.0
Styrene————3.05.07.0

The three items are identical value by value; there is only one difference, in the "existing enterprises" tier—GB 14554 provides relaxed limits for existing enterprises (ammonia 2.0, hydrogen sulfide 0.10, odor 30), while GB 18918 has no such tier. Therefore, it makes no difference which standard is applied to new wastewater treatment plants; only existing plants undergoing expansion or modification are affected.

The real difference lies in the width of the table: GB 18918 has only four rows, while GB 14554 has nine rows. It is missing six items: trimethylamine, methyl mercaptan, dimethyl sulfide, dimethyl disulfide, carbon disulfide, and styrene. And the most troublesome odor complaint is often not hydrogen sulfide, but methyl mercaptan—its limit is 0.007 mg/m³, an order of magnitude lower than that of hydrogen sulfide, and its odor threshold is at the nanogram per cubic meter level. Strictly speaking, an acceptance report that only covers ammonia, hydrogen sulfide, and odor concentration is "compliant according to industry standards," not "fully compliant for all odor parameters."

V. Monitoring Points: Three Sets of Rules, Three Answers

This section is the core of this article. For the same plant and the same gas stream, the standard provides three sets of sampling point methods, and the measured values can differ by an order of magnitude.

Table 5 Three standards, three sets of monitoring point rules, and their respective value determination methods
BasisMonitoring Point LocationNumber of PointsHeightValue Determination Method
GB 16297 Appendix C "Unit Perimeter Monitoring Points"Within the 10 m range outside the unit perimeter downwind of the emission source; if the maximum ground-level concentration area is beyond 10 m, set the points within that areaMaximum 41.5~15 mTake the highest concentration point
GB 16297 Appendix C "Upwind and Downwind Point Setting"The highest concentration point downwind of the emission source, not limited by the unit perimeter; not less than 2 m from the source; 1 reference point(s) set upwindMaximum 4 monitoring point(s), 1 reference point(s)Not limitedHighest point measured value minus reference point concentration
GB 14554 Article 5.1Specified monitoring points on the boundary of the pollutant discharge unit (without other interfering factors)Not limitedNot limitedSingle maximum monitoring value, without background deduction
HJ/T 55 Article 9.2.2The highest concentration point downwind of the emission source within 2~50 m from the source; 4 points arranged on both sides of the mean wind direction axis, with the angle not exceeding the wind direction standard deviation ±S°4Not limitedTake the highest concentration point

A single monitoring event at a hospital sewage treatment station in Xiangyin, Hunan, on 2024 年 7 月, captured these differences in one comparison table. Same hour, same set of instruments, same station:

Table 6 Four monitoring points at the same station on the same day (unit mg/m³, ammonia; limit value per GB 18466 Table 3 is 1.0)
Monitoring Point1st Time2nd Time3rd Time4th TimeMaximum
Upwind Southwest Side G1 (Reference Point)0.0120.0240.0400.0240.040
Downwind Northeast Side G2 (Monitoring Point)0.1090.0990.0600.0990.109
Downwind Northeast Side G3 (Monitoring Point)0.0680.0740.0930.0730.093

Upwind 0.012, downwind 0.109, a difference of 9.1 times. The difference 0.097 is exactly "the portion contributed by this station itself"; if the second method in Appendix C of GB 16297 is applied, the highest point minus the reference point must be taken, and the assessed value of this station becomes 0.097 instead of 0.109. This 0.012 difference between the two methods may not look like much, but it is a systematic difference—the higher the upwind background, the greater the difference between the two methods.

More noteworthy are the four values for G1: 0.012, 0.024, 0.040, and 0.024 — a spread of more than 3 times between the four. These are results from the same day, the same instrument, the same point, and interval sampling. That is to say, even standing perfectly still, a single point's own readings can drift by a factor of 3. Against this magnitude of drift, whether 0.109 or 0.093 is the "highest concentration point" depends largely on which way the wind was blowing at the moment of sampling.

The one sentence to remember from this section: A fence-line value is not "how much is emitted" — it is "at which point, at which moment, and by which set of rules it was obtained." All three standards require finding the "highest concentration point," and where that highest point is depends on wind direction, the eddies on the leeward side of buildings, and sampling height — the person placing the sampling points is part of the variable. HJ/T 55 even states explicitly that "when setting monitoring points, there is no need to avoid the influence of other sources." What this means is: drift from other factories counts against you, but you are not allowed to move the point because of it.

VI. To Subtract Background or Not: Three Standards, Three Answers

These are three ways of answering the same question, and at the fence line, all three must be used:

Table 7 Three Time Bases and Three Background Handling Approaches
ObjectEvaluation BasisHow Background Is HandledPractical Effect
Fence-line odor (GB 14554)Single maximum monitored valueNo deductionStrictest: captures peaks, counts the full account
Fence-line fugitive emissions (GB 16297, second set of monitoring points)1 小时 averageSubtract reference point concentrationModerate: counts only one's own increment
Fence-line noise (GB 12348/HJ 706)Equivalent sound level, steady-state measurement 1 minDeduction by difference tier; when the difference is too small, compliance may be judged qualitativelyLoosest: after deduction, it may actually become compliant

The three bases correspond to three philosophies. Odor targets "the moment a person smells it," so a single maximum value is taken and no background is deducted—because to the person smelling it, whether the odor is emitted by you or by the neighbor, the discomfort is the same discomfort. Fugitive particulate matter acknowledges that "the background contains others' share," so the reference point is subtracted. Noise is the most special: it is not only energy superposition (background and source are physically truly added together), but it also has a formal correction procedure, writing the matter of "being unable to distinguish" into provisions that can lead to a conclusion.

VII. Noise: The same 64 dB can be either compliant or non-compliant 3 dB

The five-tier limits in Table 1 of the "Emission Standard of Environment Noise for Boundary of Industrial Enterprises" are themselves easy to remember: Category 0 50/40, Category 1 55/45, Category 2 60/50, Category 3 65/55, Category 4 70/55 (day/night, dB(A)). The first four tiers differ by 10 dB between day and night, and only Category 4 differs by 15 dB—because Category 4 runs along major traffic arteries, where nighttime traffic volume drops faster than industrial sources. Two other points are easily overlooked: the maximum sound level of frequent nighttime noise shall not exceed the limit by more than 10 dB(A), and that of occasional noise shall not exceed the limit by more than 15 dB(A); when the plant boundary is less than 1 m from a sensitive building, measurement shall be conducted indoors, and the limit shall be further reduced by 10 dB(A).

The real trick lies in the correction. HJ 706 divides the difference ΔL1 of "measured value minus background value" into three ranges:

Table 8 Correction Rules of HJ 706—2014 (ΔL1 = Measured Value − Background Value, rounded to the nearest integer)
ΔL1DispositionCorrection Value
> 10 dBNo correction; the measured value is the emission value0
6~10 dBCorrect per table−1 dB
4~5 dBCorrect per table−2 dB
3 dBCorrect per table−3 dB
< 3 dBNot correctable: lower the background and retest; if still not satisfied, switch to the qualitative determination of ΔL2——

The path where ΔL1 is less than 3 dB is the least noticed and most consequential clause in this standard. Its logic is: since the background and the source differ by less than 3 dB, the source energy is far smaller than the background, and this dataset cannot tell which is which. Therefore ΔL1 is no longer compared; instead, the difference between the measured value and the limit ΔL2 is compared: if ΔL2 is less than or equal to 4 dB, it is judged "compliant"; if ΔL2 is greater than or equal to 5 dB, it is "not evaluable" and must be retested.

Plug the three scenarios into the same set of numbers. Take the limit as Category 2 area daytime 60 dB(A), and the measured value is 64 dB(A) in all cases:

  • Background 55 dB: ΔL1 = 9, falling within 6–10, correction −1, emission value 63 dB, exceeds the limit by 3 dB.
  • Background 62 dB: ΔL1 = 2, no correction possible; ΔL2 = 64 − 60 = 4, judged "compliant".
  • Background 64 dB: ΔL1 = 0; ΔL2 = 6, "cannot be evaluated", retesting required.
The same 64 dB with three different backgrounds, three different outcomes
Figure 1 The same measured value 64 dB(A) and the same limit 60 dB(A), but with different backgrounds, the conclusion runs all the way from "exceeds the limit by 3 dB" to "judged compliant". Based on Article 5.3, Table 1 and Article 6.2, Table 2 of HJ 706—2014.

There is an even simpler provision, Article 6.1: if the measured value itself is below the limit, background measurement and correction may be omitted, and compliance can be judged directly with a note. This provision means that a large number of "compliance reports" contain no background value at all—not because it was omitted by mistake, but because it is legitimately left out. Once the measured value exceeds the limit, however, the background becomes the only thing that can save it.

So when reviewing a factory-boundary noise report, first look at three numbers: the measured value, the background value, and ΔL1. A report that gives only the measured value and a statement of "compliant" cannot stand when the measured value exceeds the limit; a report that gives only "cannot be evaluated" does not mean the limit is exceeded either—it merely says the data cannot be statistically distinguished. The basis for deciding whether remediation is really needed is the emission value that still exceeds the limit after background correction.

VIII. Distance is cheaper than a silencer: how far can a 85 dB blower carry

Noise is energy and attenuates with the square of distance. A point source (a single piece of equipment) drops by 6 dB for every doubling of distance, and a line source (an open channel, a section of oxidation ditch water surface) drops by 3 dB for every doubling of distance. These two formulas are quite accurate when there are no barriers and the ground is flat, and can be used directly for siting decisions.

Table 9 Distance Attenuation and Unit Superposition (Point Source 20lg, Line Source 10lg, Multiple Units 10lgN)
DistancePoint Source at 1 m, 85 dBLine Source at 1 m, 75 dB3 Units of 85 dB in Parallel
10 m65.065.075.0
20 m59.062.069.0
30 m55.560.260.2
50 m51.058.055.8
100 m45.055.049.8
Distance attenuation curves for point and line sources and the three-tier limits
Figure 2 Attenuation curves for point sources (blowers, dewatering machines) and line sources (oxidation ditch water surface, open channels), with a logarithmic horizontal axis. The three dashed lines are the daytime limits in GB 12348 Table 1. The line source follows 55 dB throughout the entire 100 m range, which is why "water surface noise" is harder to control than "machine noise".

Two intersection points can be seen in this figure. The first: a 85 dB blower must be set back to 30 m to drop to 55.5 dB, just enough for the daytime limit of Category 1 areas; it must be set back to 100 m to drop to 45 dB, enough for the nighttime limit of Category 1 areas. Three units in parallel give 89.8 dB, and at the same 30 m the level is 60.2 dB—exactly on the daytime 60 line for Category 2 areas, with no margin at all. The second: the line source at 75 dB still registers 60.2 dB at 30 m, and 55.0 dB at 100 m. Line sources attenuate slowly, so an open water surface cannot be shielded no matter how far the wall is.

Add these two numbers and the background together: outside the plant boundary there is already a 55 dB background (roads, other plants, residents themselves); superimposing a 55.5 dB source on top gives 58.3 dB, which still appears to be within 60; but if the background is 50, after superposition it becomes 56.6; with a background of 45, after superposition it becomes 55.9—for every 5 dB the background drops, the total sound level drops by less than 1 dB. This is the arithmetic reason why "noise control stops working beyond a certain point": once the source is reduced to the same order of magnitude as the background, further reducing the source barely moves the total sound level.

Conversely, location is the cheapest option. Moving the equipment room from 10 m inside the wall to 60 m, from 65.0 dB down to 49.4 dB, saves 15.6 dB, more than the lower limit of "movable sealed soundproof enclosure 15–30 dB" in GBZ 1, and it consumes no electricity, requires no maintenance, and does not fail just because an access door is left open. This arithmetic is almost always wasted on new projects—at the general layout stage, the location of noise sources is often determined by piping routing rather than by the boundary wall position.

IX. Emission standards copied from quality standards: everyone complies, yet the area still exceeds limits

The five-tier limits in Table 1 of GB 12348 are identical digit for digit to the limits for the same functional zones in the "Environmental Quality Standard for Noise" GB 3096: Category 2 zones are both day 60, night 50; Category 1 zones are both day 55, night 45. One governs "how much an enterprise emits beyond its plant boundary," the other governs "how quiet this area should be," yet the values are the same.

Identical values lead to an inevitable result. Suppose there are four enterprises along a road, each measuring 55 dB(A) at its own plant boundary—all below 60, all four fully compliant. But the contributions of these four add up:

Table 10 Superposition values when n enterprises each contribute 55 ddB(A) (10lgN)
Number of Enterprises123456
Superposed Sound Level dB(A)55.058.059.861.062.062.8
Comparison with Class 2 quality standard 60CompliantCompliantCompliantExceedanceExceedanceExceedance

When the fourth enterprise appears, the area exceeds the standard, yet none of the individual enterprises does. "Compliance at the plant boundary" does not imply "compliance of the area". This is not lax enforcement; it is because the emission standard limits directly adopt the values of the quality standard—it ensures that "a single enterprise alone will not push the area over the limit," but it does not ensure that "multiple enterprises combined will not exceed it." Therefore, whether the area complies can only be demonstrated by superposition prediction at the environmental impact assessment stage, not by the individual compliance of each enterprise in acceptance monitoring. Yet acceptance monitoring is precisely conducted enterprise by enterprise.

X. Five Real Acceptance Cases: Air Margin 4 to 15 Times, Noise Margin 0 to 21 Decibels

Laying out five publicly available completion environmental protection acceptance monitoring reports, the margins for air and noise are completely on different orders of magnitude.

Table 11 Plant boundary field measurements of five publicly disclosed acceptance cases (percentages of limit values in parentheses)
ItemAmmonia mg/m³Hydrogen Sulfide mg/m³Odor ConcentrationPlant Boundary Noise dB(A)
Jinan Yaoqiang Integrated Station (West Station)0.18(12%)0.004(6.7%)11(55%)Day 50.3/Night 44.3
Jinjiang Xianshi Wastewater Treatment Plant 14.1 万 m³/d0.327(21.8%)0.023(38.3%)14(70%)All 8 points compliant
Xintai Gongli Town Wastewater Treatment Plant0.188(12.5%)0.018(30.0%)14(70%)Day 36.4~38.3/Night 27.4~35.2
Fu'an Saiqi Town Wastewater Treatment Plant Phase I0.372(24.8%)0.046(76.7%)18(90%)Exceedance on three sides
Xiangyin Hospital Wastewater Station (downwind)0.109(10.9%,limit 1.0)Not detectedNot detectedDay 51.4~55.8/Night 45.8~48.6

In the air column, the three items each have their own margin: ammonia has 4 to 8 times the headroom, hydrogen sulfide 1.3 to 15 times, and odor concentration is the tightest, at only 1.1 to 1.8 times. Fu'an Saiqi is a borderline sample: hydrogen sulfide at 0.046 accounts for 76.7% of the limit, and odor at 18 accounts for 90%—this is already at the "just passing" level, indicating that odor is indeed the plant's own main environmental issue. But even for it, all three air items fully comply.

The problem lies in noise. The acceptance conclusion for Fu'an Saiqi states it clearly: the north side meets the standard; the south side exceeds the standard at night due to tailwater discharge; the east side exceeds the standard during the day due to the operation of dewatering equipment; the west side exceeds the standard at night due to the loud water flow noise in the oxidation ditch. Three sides, three different causes: one is the water drop, one is the machinery, one is the water surface. The treatment measures for these three things are completely non-interchangeable—tailwater requires energy dissipation, dewatering machines require soundproof enclosures, and the oxidation ditch water surface requires covering or converting surface aeration to fine-bubble aeration. One plant hitting all three at once means it is not "which piece of equipment is noisy," but rather the water of the entire plant is making noise.

Now look at the margin, calculated at the most unfavorable measurement point. Jinan Yaoqiang East Station: daytime 51.8, nighttime 45.7, against 2 class limits of 60/50, margins of 8.2 dB and 4.3 dB; Xintai Gongli Town: daytime 36.4–38.3, nighttime 27.4–35.2, the margins corresponding to the most unfavorable values are 21.7 dB and 14.8 dB. Both are wastewater treatment plants, yet the daytime margin differs by 13.5 dB and the nighttime margin by 10.5 dB. The reason is not equipment quality, but background: the Xintai plant is in a town surrounded by farmland, where the nighttime background may be only 30 dB; the Jinan station is next to an urban area, where the background itself is already close to the limit. So "noise compliance" is something that is half predetermined by factors beyond the enterprise's control—which is also why the same set of equipment, at a different plant site, can change the conclusion from "exceeds by 3 dB" to "margin of 20 dB."

11. Covering Is Not More Environmentally Friendly—It's Switching to a Different Accounting Book

Since the plant boundary allows only 0.06 mg/m³, while the measured hydrogen sulfide in the gas phase above the tank surface is typically 50–70 mg/m³, the difference is 833 to 1167 times. This gap is achieved through atmospheric dispersion—the open water surface is an area source, and once the gas emerges it is mixed, diluted, and lifted. But this is a very fragile accounting: low wind, temperature inversion, eddies—any one condition changing, and the numbers outside the wall change with it.

So the standard engineering solution is covering and collection, converting the fugitive area source into an organized emission. With this change, the applicable clause shifts from "plant boundary concentration 0.06 mg/m³" to "stack emission rate 0.33 kg/h (15 m)." Concentration has been replaced by rate, and there is no conversion relationship between the two numbers unless the air volume is specified first.

Table 12 Concentration converted from the same 0.33 kg/h under different collection air volumes
Collection Air Volume m³/h1000300060001000030000
Converted to outlet concentration mg/m³330110553311
How many times the plant boundary 0.0655001833917550183
Switching of limit basis under the two scenarios of uncapped and capped collection
Figure 3 What changes before and after capping is not the emission amount, but the basis of the limit: on the left, it is judged by the plant boundary concentration 0.06 mg/m³; on the right, by the stack emission rate 0.33 kg/h. The smaller the air volume, the higher the concentration corresponding to the same rate—this is why "collection rate" deserves more attention than "concentration."

This table explains a commonly misunderstood phenomenon: after a certain plant was capped, the stack measured over 30 mg/m³, and when compared with the plant boundary limit 0.06, it looked like an exceedance of 500 times. In fact, it is compliant—because it discharges from a 15 m-high stack, relying on height for dilution; the plant boundary line is below 15 m and tens of meters away, where the concentration must be measured separately.

But conversely, there is also a real trap: the smaller the air volume, the higher the concentration converted from the same rate. If the cover is not tight and the collection rate is only 60%, and the air volume is reduced to 3000 m³/h to save money, the outlet concentration will be 110 mg/m³. The rate is still compliant, but this means a considerable portion of the odor has not been collected and is still escaping fugitively from the tank surface—the plant boundary account has not been closed by covering; it has merely been shifted into the parameter of "collection rate," which no one assesses.

Twelve. Sanitary Protection Distance: Between 50 m and 100 m Is a "One-Level Upgrade"

Beyond the plant boundary there is another layer: the sanitary protection distance. What it governs is not the emission concentration, but "no one is allowed to live on this land." The algorithm is in the Technical Guidelines for Derivation of Sanitary Protection Distance for Fugitive Emissions of Hazardous Air Pollutants:

Qc / Cm = (1/A) · (B·LC + 0.25r²)0.50 · LD

Qc is the fugitive emission rate (kg/h), Cm is the standard concentration limit, r is the equivalent radius of the production unit, and L is the protection distance to be determined; A, B, C, and D are coefficients selected according to the local average wind speed over the past five years and the source composition category.

What is more error-prone than the formula is two rules: ① When the initial value calculated is less than 50 m, the final value shall be taken as 50 m, and the level difference is 50 m; ② When a production unit has multiple characteristic hazardous air pollutants, if the initial values derived separately fall within the same level, the final value shall be raised by one level. The second rule is the real reason many projects go from 50 m to 100 m—not because the calculated value becomes larger, but because "both pollutants are calculated in the same tier, so the level is raised by one."

The environmental impact assessment of the Chengdu Maojiawan Wastewater Treatment Plant states it very directly: the original approval for Phase I set 50 m centered on "odor sources such as the grit chamber, lifting pump house, sludge storage tank, and dewatering room"; during reconstruction and expansion, according to the new guidelines, hydrogen sulfide and ammonia were derived separately as two characteristic pollutants, and both fell in the same level, so "a sanitary protection distance of 100 m shall be set starting from the boundary of the structures generating odor." From 50 m to 100 m, the enclosed area is 4 times.

This line becomes a specific constraint during the operation period. A key description in the odor control renovation of the Chongqing Jiguanshi Wastewater Treatment Plant says: the drying machine room "is immediately adjacent to the western wall of the plant boundary, and outside the wall 200 m is a residential community." Once the distance is this close, the conventional 15 s retention time is insufficient—they set 25 s for the low-concentration area (coarse screen, influent pump house, biological reaction tank) and 40 s for the high-concentration area (fine screen vortex grit chamber, primary sedimentation tank, sludge thickening tank), and also used two modules to culture acidophilic bacteria (25 s) and neutrophilic bacteria (15 s) respectively for targeted removal, raising the removal rate from the conventional 90% to 95%–99%.

Thirteen. The Accounts of Odor Control and Noise Reduction: Two Routes, Two Units

Putting the means of the two fronts into one table reveals that their "effect units" are fundamentally different: odor control is measured by removal rate, noise reduction by insertion loss, and both ultimately have to land on the same plant boundary.

Table 13 Measured parameters of three technical routes for biological odor removal at municipal wastewater treatment plants
RouteAir Flow m³/hEmpty Bed Residence TimeInlet H₂SRemoval PerformanceApplicability Assessment
Biofiltration (a plant in Tianjin)1100015 s2.5~3.5 mg/m³ (VOCs 200~300)H₂S 100%, VOCs >90%Large air volume, low concentration
Biotrickling filtration (a plant in California, USA)163002 s45.5~91.1 mg/m³H₂S 95%, removal loading 105 g/(m³·h)High sulfur content, prone to acidification
Bioscrubbing (a plant in Denmark)6000——Annual average 10, summer-autumn 25~35 mg/m³H₂S and organic sulfur >99%High concentration, hydrophilic

The difference among the three routes can be summed up in one sentence: residence time is traded for removal efficiency, but the efficiency of the trade differs. The biotrickling tower in California removes 95% of hydrogen sulfide from 45.5~91.1 mg/m³ with only 2 s, because its packing has a specific surface area of 600 m²/m³ and a bed height of 3.7 m, giving a biomass density far higher than that of conventional filters; the filter bed in Tianjin requires 15 s to bring inlet gas of 2.5~3.5 mg/m³ down to 100%, because the inlet gas is already dilute—it wins on thoroughness rather than loading. The residence time of single-stage biofilters commonly used in domestic projects is 15~40 s, with 25 s adopted for the low-concentration range and 40 s for the high-concentration range—this is consistent with the conclusions of another biotrickling tower test: at hydrogen sulfide concentrations of 40~90 mg/m³, the removal efficiency stably exceeds 90% only when the residence time is above 25 s.

Table 14 Insertion Loss of Common Noise Reduction Measures (GBZ 1 and General Engineering Values)
MeasureInsertion Loss dB(A)Effective AgainstIneffective Against
Fixed sealed acoustic enclosure30~40Noise radiated from unit casingNot applicable when no maintenance space is available
Movable sealed acoustic enclosure15~30Equipment requiring door accessSound leakage through door gaps and cable holes
Acoustic enclosure with ventilation and heat dissipation silencer15~25Heat-generating equipmentShutdown occurs if heat dissipation air volume is insufficient
Partially open acoustic enclosure10~20Equipment with inlet/outlet openings that cannot be sealedOpening facing directly toward sensitive receptors
Inlet/exhaust silencerUp to 20~35 (generally should not exceed 50)Aerodynamic noiseCasing radiated noise
Noise barrier10~20Directional shielding, line sourcesDiffraction; effectiveness decays rapidly beyond 30 m
Soundproof room (duty room)20~50Protects people, does not reduce emissionsNo contribution to plant boundary

One row in the table deserves separate mention: "Soundproof room 20~50 dB, but no contribution to plant boundary." It protects the people inside, not reducing sound levels outside the walls. Such measures score full marks on the occupational health account but zero on the plant boundary account—the two accounts cannot offset each other. Similarly, the silencing capacity of a silencer "generally should not exceed 50 dB," and the flow velocity in pipes has an upper limit: inlet and exhaust pipes of blowers and compressors are 30 m/s, internal combustion engine exhaust 50 m/s, venting 60 m/s. If the flow velocity is exceeded, the silencer itself becomes a noise source.

XIV. Turn This Article into a Checklist

  1. First determine where the plant boundary is. The definition in GB 12348 rests on legal documents—the boundary determined by the land use certificate, property ownership certificate, and lease contract. If the boundary is drawn wrong, the limits, measurement points, and conclusions will all be wrong accordingly.
  2. First determine the functional zone, then select the limits. What is examined is the acoustic environment functional zone outside the plant boundary, not inside the plant. How noisy it is inside the plant is not governed by this standard.
  3. For air, look at four items, not just three. Table 4 of GB 18918 contains only ammonia, hydrogen sulfide, odor concentration, and methane; GB 14554 additionally includes methyl mercaptan, dimethyl sulfide, dimethyl disulfide, trimethylamine, carbon disulfide, and styrene. The limit for methyl mercaptan is 0.007 mg/m³, an order of magnitude lower than that for hydrogen sulfide.
  4. Record methane on a separate line. The unit is volume percentage, the measurement point is inside the plant, and the purpose is explosion prevention (1% = 20% LEL). Do not compare it on the same basis as items in mg/m³.
  5. Odor concentration 20 means "just smelled." It does not mean "not smelled." Only 10 under the Class I standard is odorless, and 10 is at the same time the method detection value.
  6. The location of the monitoring point is the conclusion. 10 m outside the perimeter, 2–50 m downwind, and on the boundary—three locations, three numbers; at the same station, the measured values upwind and downwind can differ by 9 times.
  7. Whether background is deducted must be clearly justified. Odor is not deducted, unorganized emissions are reduced by the reference point, and noise is deducted in tiers according to ΔL1. If mixed within the same report, the conclusion cannot be reviewed.
  8. A noise report must include background values. When the measured value is higher than the limit, without a background value there is no emission value; when ΔL1 is less than 3 dB, giving "cannot be evaluated" is compliant and does not equal exceeding the standard.
  9. Calculate distance first, then buy equipment. For a point source, each doubling of distance reduces by 6 dB; moving a machine room from 10 m to 60 m saves 15.6 dB, more than the lower limit of a movable sealed acoustic enclosure.
  10. Compliance at the plant boundary does not equal compliance in the area. Four facilities at 55 dB each superimpose to 61 dB; the area exceeds the standard, yet none of them exceeds it individually.
  11. For covering, focus on capture rate, not concentration. At the same 0.33 kg/h, when the air volume drops from 10000 to 3000, the outlet concentration rises from 33 to 110 mg/m³; the rate remains compliant, and the missed portion returns to the plant-boundary account.
  12. The protection distance is often determined by "raising one level." When the initial values of two characteristic pollutants are at the same level, the final value is raised by one level; from 50 m to 100 m, the area differs by 4 times.

References

  1. State Environmental Protection Administration, General Administration of Quality Supervision, Inspection and Quarantine. Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB 18918—2002), Table 4 "Maximum Allowable Concentration of Waste Gas Emission at Plant Boundary (Edge of Buffer Zone)" and Article 4.2.
  2. State Environmental Protection Bureau, State Bureau of Technical Supervision. Emission Standards for Odor Pollutants (GB 14554—93): Table 1 Standard Values of Odor Pollutants at Plant Boundary, Table 2 Emission Standard Values of Odor Pollutants, Article 4.2.1, Article 5.1.
  3. State Environmental Protection Bureau. Integrated Emission Standard of Air Pollutants (GB 16297—1996), Appendix C: C1 Unit Perimeter Monitoring Points, C3.1~C3.3 Upwind Reference Points and Downwind Monitoring Points, and Value Determination Method.
  4. State Environmental Protection Administration. Technical Guidelines for Monitoring Fugitive Emission of Air Pollutants (HJ/T 55—2000), Articles 9.2.2.1~9.2.2.3: Monitoring points set at the highest concentration point within the downwind range of 2~50 m, layout of 4 points and ±S° included angle, and treatment of eddy zones.
  5. Ministry of Environmental Protection. Emission Standard for Industrial Enterprises Noise at Boundary (GB 12348—2008): Table 1 Emission Limits for Environmental Noise at Plant Boundary, Articles 4.1.2~4.1.5, Articles 5.2~5.4, and the definition of "Plant Boundary" in Chapter 3.
  6. Ministry of Environmental Protection. Technical Specifications for Environmental Noise Monitoring — Correction of Noise Measurement Values (HJ 706—2014): Article 4.5 Background Reference Point, Articles 5.2~5.4 and Table 1, Articles 6.1~6.2.3 and Table 2.
  7. Ministry of Environmental Protection, General Administration of Quality Supervision, Inspection and Quarantine. Environmental Quality Standard for Noise (GB 3096—2008), Table 1 Environmental Noise Limits (Category 1 55/45, Category 2 60/50).
  8. Ministry of Ecology and Environment. Technical Guidelines for Derivation of Health Protection Distance for Fugitive Emission of Hazardous Air Pollutants (GB/T 39499—2020): Initial Value Calculation Formula for Health Protection Distance, 50 m Grading Rule, and the Rule of Raising One Grade for Multiple Characteristic Pollutants at the Same Level.
  9. Ministry of Health. Occupational Exposure Limits for Hazardous Agents in the Workplace — Part 1: Chemical Hazardous Agents (GBZ 2.1—2019): Maximum Allowable Concentration of Hydrogen Sulfide 10 mg/m³, Ammonia PC-TWA 20 mg/m³ and PC-STEL 30 mg/m³.
  10. Ministry of Health. Hygienic Standards for the Design of Industrial Enterprises (GBZ 1—2010), Article 6.2.3.2 and Table 4 "Noise Reduction of Different Types of Acoustic Enclosures", Table 5 "Airflow Velocity in Silencers and Ducts" (Public Text of National Occupational Health Standards, National Institute of Occupational Health and Poison Control, Chinese Center for Disease Control and Prevention).
  11. Jia Tipei, Wang Can, Zhang Liang, Zhao Qi, Peng Yongzhen. Key Influencing Factors and Case Analysis of Biological Deodorization Technology in Municipal Wastewater Treatment Plants. Chinese Journal of Environmental Engineering, 2022, 16(4). DOI: 10.12030/j.cjee.202111036. (Deodorization systems installed in 81%~91% municipal wastewater treatment plants, with biological methods accounting for 78%, chemical scrubbing 11%, and Activated Carbon 2%; air volume, retention time, inlet concentration and removal rate of three engineering cases in Tianjin, California, USA, and Denmark).
  12. Systematic Concept-Based Retrofitting of Deodorization Engineering in a Large Wastewater Treatment Plant (Chongqing Jiguanshi Wastewater Treatment Plant): Single-stage Biological Aerated Filter retention time 15~40 s, low-concentration zone 25 s and high-concentration zone 40 s, dual-module acidophilic 25 s/mesophilic 15 s, removal rate increased from 90% to 95%~99%, drying machine room adjacent to a residential community 200 m outside the western boundary wall.
  13. Biotrickling Filter Technology for Hydrogen Sulfide Waste Gas Treatment in Wastewater Treatment Plants (Zhejiang Kangjiachii Environmental Protection Technology Co., Ltd., Zhejiang Zhouhuan Environmental Engineering Design Co., Ltd.): Hydrogen Sulfide 40~90 mg/m³, removal rate above 90% at retention time 25 s; hydrogen sulfide mass concentration in wastewater treatment plants generally 50~70 mg/m³.
  14. Jinan Municipal Ecology and Environment Bureau. Public Notice of Completion Environmental Protection Acceptance for the Integrated Wastewater Treatment Project at Yaoqiang Subdistrict (2020): Maximum odor concentration at the west station boundary 11, ammonia 0.18 mg/m³, hydrogen sulfide 0.004 mg/m³; east station daytime 51.8 dB(A), nighttime 45.7 dB(A), west station daytime 50.3, nighttime 44.3.
  15. Jinjiang Municipal People's Government. Completion Environmental Protection Acceptance Opinion for the Expansion to 5 万 tons/day and Upgrading and Retrofitting Project of Jinjiang Xianshi Wastewater Treatment Plant (Jin Huan Bao [2017] Yan Shu No. 14): Average daily treatment 140750 t, plant boundary ammonia 0.327 mg/m³, hydrogen sulfide 0.023 mg/m³, odor 14, plant area methane 8.6×10⁻⁵%, all 8 noise points at the plant boundary meet Category 2 standards.
  16. Xintai Sunde Water Affairs Co., Ltd. Completion Environmental Protection Acceptance Monitoring Report Form for Gongli Town Wastewater Treatment Plant: Plant boundary ammonia 0.188 mg/m³, hydrogen sulfide 0.018 mg/m³, odor 14; plant boundary daytime 36.4~38.3 dB(A), nighttime 27.4~35.2 dB(A).
  17. Fu'an Municipal People's Government. Public Notice of Approval Opinion for the Completion Environmental Protection Acceptance Monitoring Report of Phase I Project of Saiqi Town Wastewater Treatment Plant (2017): Maximum hydrogen sulfide at 4 monitoring points 0.046 mg/m³, ammonia 0.372 mg/m³, odor 18; noise at the plant boundary exceeded standards at nighttime due to the south side tail water, daytime due to the east side dewatering equipment, and nighttime due to the west side oxidation ditch water flow sound, respectively.
  18. Hunan Shanshui Testing Co., Ltd. Monitoring of Fugitive Waste Gas at the Perimeter and Boundary Noise of the Wastewater Treatment Station of a Hospital Construction Project (2024-07-09): Upwind G1 ammonia 0.012~0.040 mg/m³, downwind G2 0.060~0.109, G3 0.068~0.093 mg/m³, hydrogen sulfide and odor concentration not detected; boundary noise daytime 51.4~55.8, nighttime 45.8~48.6 dB(A), limits in accordance with GB 18466—2005 Table 3 and GB 12348—2008 Category 2.
  19. Environmental Impact Report Form for Phase I Stage II Project of Maojiawan Wastewater Treatment Plant in Tianfu New Area (2021): A health protection distance of 50 m was originally set centered on odor sources such as the grit chamber, lifting pump house, sludge storage tank, and dewatering room; for the expansion and retrofitting, hydrogen sulfide and ammonia were derived separately in accordance with GB/T 39499—2020 and raised one grade at the same level, with a final value of 100 m.

All multiples, margins and conversions in this article are calculated based on the provisions of public standards and acceptance report data, and the calculation basis has been noted in the tables; engineering case data are cited from public acceptance notices and literature, and the back-calculation columns are used to verify the calculation basis rather than to evaluate the projects. Plant boundary limits and monitoring point rules shall be subject to the currently effective versions; for expansion and retrofitting projects, please verify the implementation requirements of the local ecology and environment authorities.

您提供的内容似乎不完整,缺少需要翻译的中文文本。请提供待翻译的中文内容,我将根据术语表为您翻译成地道的英文。
Copyright © 2026 TIANYI LIMITED All Rights Reserved