Filter bed: 5–8 m/h is not a selected value; it is achieved by removing that 20 mg from the influent.

Nationwide multi-industry applications (centralized wastewater treatment plants
Pilot to full-scale engineering (tens of thousands to 200,000 m³/d; filtration r

Filter: 5~8 m/h Is Not Selected, It Is Removed From Those 20 Milligrams in the Influent

The previous article discussed the plant boundary, where what was replaced was the "monitoring point"; this article discusses the filter, where what is replaced is the "filtration rate." The same symbol v is given as 8~10 m/h on the water supply side in the standards, and only 5~8 m/h on the drainage side; the 3 m/h in between is not a matter of conservatism—it is a function of the influent Suspended Solids concentration. And how many times a day the filter must be backwashed, and how much water each backwash consumes, are all governed by a product that no one treats as a parameter: filtration rate × cycle.

Gaowutong · Industrial Water Treatment Technology Series · For industry technical personnel · All data are annotated with public standard clauses and literature sources

First, three numbers, all written under the single word "filter." For the same V-type filter, the water supply side normal filtration rate is 8~10 m/h, and the forced filtration rate is 10~13 m/h (GB 50013—2018); the drainage side gives only 5~8 m/h, and there is no provision for forced filtration rate (GB 50014—2021). What about the solids loading of the filter media? The operational control threshold is 0.5~1.0 kg/m³, the value back-calculated from standard clauses is 1.0~3.2 kg/m³, and the ultimate capacity measured in the literature is 5.5 / 7.8 / 12.52 kg/m³—the minimum and maximum differ by 25 times. All three numbers are called solids loading, all are used by someone for design, and they answer three different questions: whether backwashing is needed, what value the clauses are based on, and how much the filter media can hold.

I. First, positioning: the filter only moves the solid phase; it does not change the valence of anything

In the advanced treatment stage, the most common arrangement is "high-efficiency sedimentation tank + filter." Both are solid-liquid separation equipment, but their division of labor differs: the sedimentation tank uses gravity to settle flocs, while the filter uses the pores of the filter media to intercept fine flocs that have not settled cleanly. Therefore, the first sentence of the filter's positioning must be fixed: it does not degrade COD, does not remove nitrogen, does not remove phosphorus, and does not disinfect. It does only one thing—move already-formed solids from the water to outside the water.

This must be stated clearly first, because many on-site arguments that "the filter is not working well" actually conflate two things into one. High influent COD and high filter effluent COD do not mean the filter has failed; they mean the preceding flocculation was not done well, and the filter merely faithfully let through the colloids that were not intercepted. How large is the real removal capacity? The pilot test at Jinan No. 2 Water Treatment Plant provided a set of comparisons: for the same V-type fiber filter, under the conditions of filtration rate 20 m/h and cycle 23 h, SS removal rate was above 70%, COD was only 5%~33%, and ammonia nitrogen was 4.5%~14%. That small amount of COD and ammonia nitrogen removal is essentially the portion intercepted along with SS, not the filter oxidizing anything.

Table 1 Position of the filter in the process: what it moves and what it does not
ItemWhat the filter can doWhat the filter cannot do
Suspended Solids / SSIntercepts already-formed flocs and particles; when influent is <20 mg/L, removal exceeds 70%~80%Cannot replace coagulation; when colloids are not destabilized, they cannot be intercepted and simply pass through the bed
CODRemoves only the portion "attached to SS"; measured 5%~33%Does not oxidize dissolved organic matter; the influent-effluent COD difference mainly reflects the SS difference
Ammonia Nitrogen / Total Nitrogen / TNAlmost no removal (measured 4.5%~14%, attributable to sludge carryover)Is not a Nitrification or Denitrification unit; nitrogen removal requires a Denitrification filter (anoxic biofilm)
Total Phosphorus / TPRemoves only particulate phosphorus, which leaves together with SSDoes not remove dissolved orthophosphate; upstream chemical phosphorus removal is required
HeadConsumes 2.0~2.5 m (V-type) / 0.2~0.4 m (rotary disc)Does not generate head; allowance must be reserved in the hydraulic profile, otherwise negative head occurs

The last row of Table 1 is the real entry point of this article. On a process diagram the filter is a box, but in section it is a resistance element packed full of filter media—influent is pushed through by the upstream water level, and once the effluent elevation is set incorrectly, negative pressure develops within the filter bed, dissolved gases in the water come out of solution, the bed is lifted open by bubbles, and filtration fails outright. Section 11 will calculate this specifically.

II. One Product: Four Sets of Measured Data Lock "Filtration Rate" and "Cycle" onto a Single Line

When designing a filter, the standard specifies two parameters: filtration rate v (m/h) and filtration cycle T (h). They appear to be two degrees of freedom, but in fact they are one. The reason is straightforward: the amount of sludge a filter can hold within one cycle is limited; once the influent concentration is fixed, the volume of water that can be treated is fixed, and volume = filtration rate × time × area. Normalizing the area yields a single product:

Cycle water production W = v × T (unit m³/m²)

This equation requires no derivation; it is merely the result of unit conversion. But its meaning is rarely pointed out: as long as you fix W, v and T can only be chosen one of the two; as long as W is determined by the influent water quality, v is not yours to choose.

The pilot-scale data from Jinan No. 2 Water Treatment Plant is the cleanest evidence for this statement. With the same fiber filter, raising the initial filtration rate from 10 all the way to 40 m/h, while controlling the effluent turbidity below 1 NTU, the measured effective filtration cycles were 47, 23, 15, and 12 h. Multiplying the four sets of numbers one by one:

Table 2 Four measured groups: filtration rate varies by 4 times, cycle shortens almost by 1/4, product remains constant
Initial Filtration Rate (m/h)Effective Filtration Cycle (h)Product W (m³/m²)Deviation from Mean
1047470+1.1%
2023460−1.1%
3015450−3.2%
4012480+3.2%
Mean—465Range 30, 6.5% of mean

The same paper also reports a cycle water production of 440 m³/m² (net water production, already deducting backwash downtime and initial filtrate). This section uses the product of the four filtration rates and cycles for comparison, which is the gross value 460; the gross-net difference is 4.3%, which does not affect the conclusion that the product remains constant, but a reminder: when reporting "cycle water production", it must be stated whether it is gross or net, otherwise it is another invisible denominator.

This is the strongest table in this article. The filtration rate has increased by a factor of 4, the cycle has shrunk to 1/4, and the product has shifted by only 6.5%. In other words, the "capacity" of that filter is a constant: 465 m³/m². When you change the filtration rate from 6 to 8 in the design documents, you are not making the filter produce 33% more water; you are making it enter backwashing 25% earlier. The total water production of the filter does not change at all; what changes is only "how often it is washed" and "how poor the effluent is during washing".
Hyperbolic relationship between filtration rate and filtration cycle
Figure 1 Horizontal axis: filtration rate; vertical axis: cycle. The four dashed lines are equal-water-production lines under different dirt-holding capacities (330 / 180 / 90 m³/m²), and the red line is the measured 465 m³/m². The segment given by the code (blue box, v 5~8 × T 12~24 = 60~192 m³/m²) occupies only a small patch at the lower left corner of the measured curve in the figure.

III. The two ranges in the code are the two ends of the same product segment

Now substitute the two ranges in the code into this product. Clause 7.11.8 of GB 50014—2021 specifies for "V-shaped filters with uniformly graded quartz sand filter media": filtration rate 5~8 m/h, filtration cycle 12~24 h. Multiplying the four corners gives:

Table 3 Product of the two ranges in the standard: 60~192 m³/m², spanning 3.2 times
CombinationFiltration Rate (m/h)Cycle (h)W (m³/m²)Corresponding Backwashes per m² per Day
Most Conservative Corner512602.0 times
Median6.5181171.33 times
Most Aggressive Corner8241921.0 times
Measured (Fiber Filter)10~4047~124650.5~2.0 times

The three rows in Table 3 are not three "value preferences" but three different influent solids loadings. This can only be clearly seen through the back-calculation in Section 5, but first remember one number: the standard range covers only 13%~41% of the measured capacity (60/465 to 192/465). The standard is not wrong; it simply treats the filter as a "polishing" unit—Article 7.11.8 explicitly states the premise at the outset: the influent SS to the filter should preferably be less than 20 mg/L. In the Jinan pilot test, however, the influent was secondary clarifier effluent, with SS often around 10 mg/L. The cleaner the influent, the longer the same filter bed can last, and the larger W becomes.

A common pitfall in second-hand sources—let me correct it while I'm at it. Several V-filter design calculation sheets found in searches state "normal filtration rate 8~10, forced filtration rate 10~13" as "in accordance with GB 50013—2018, Article 9.5.8". Checking the original text of the clause: Article 9.5.8 contains only two sentences—"The filter shall be designed based on the filtration rate under normal conditions, and shall be checked based on the forced filtration rate under maintenance conditions." It contains no numerical values; the values are in Table 9.5.9. Citing the wrong article number does not affect the design itself, but it will prevent reviewers from finding the source, and it also obscures one thing: normal filtration rate and forced filtration rate are two values serving different purposes, not the upper and lower limits of the same value.

IV. Three "solids loading capacities", differing by a factor of 17

The previous section left one term undefined: solids loading capacity. It is the quantity most easily treated as "a constant" in filter design, yet in reality there are at least three sets, each serving a different purpose.

Table 4 Three sets of solids loading: answering three different questions
NameValue (kg/m³ filter media)Who uses itThe question it answers
Operational control threshold0.5~1.0Automatic control logic, backwash triggering"Should it be washed now?" — determined by the head loss reaching its limit first, not by the filter media being saturated
Code-derived value1.0~3.2Projects designed per the code"Per the code, how much sludge should be intercepted per cell per cycle?" — see Section 5
Ultimate solids holding capacity5.5 / 7.8 / 12.52Filter media selection, filter expansion"How much can the filter media hold at most?" — capacity before breakthrough, unreachable under most operating conditions
Log-scale comparison of the three sets of solids loading
Figure 2 For the same filter, the three solids loadings span 25 times (log scale). Ratio of the highest value to the median operational threshold: 12.52 ÷ 0.75 = 16.7 times. All three numbers have appeared in published literature, and none of them is wrong, but mixing them up will cause the filtration cycle to be miscalculated by an order of magnitude.

Why is the operational threshold as low as 0.5~1.0? Because what triggers backwashing is not "the filter media being full," but "the head loss hitting the ceiling." A patent on a filter backwashing system (CN115364536B) states the control logic plainly: the cumulative amount of suspended solids in the filter is accumulated hourly based on the influent flow rate and influent SS, and a backwash command is issued when it reaches 0.5~1.0 kg/m³. Meanwhile, Article 9.5.26 of GB 50013—2018 specifies a pre-backwash head loss of 2.0~2.5 m for the V-type filter — this head is only enough to use the upper small portion of the filter bed.

One sentence in the clause explanation is almost self-incriminating: the V-type filter uses a coarse-grained uniformly graded filter medium, whose porosity is larger than that of fine sand, so the head loss grows slowly, and the working cycle could originally reach 36~72 h or even longer; but an excessively long cycle will cause organic matter to accumulate within the filter layer and bacteria to grow, producing viscous substances that are difficult to remove, so "based on nearly ten years of domestic design and operating experience, the head loss before backwashing is adjusted to 2.0~2.5 m". In other words, the value 2.0~2.5 m is not the capacity limit of the filter medium, but an artificially suppressed upper limit for controlling biological viscosity. This is the root reason why the solids loading capacity has three values.

V. Back-calculation: 20 mg/L is the premise, 5~8 is the result

Now connect Table 3 and Table 4. The amount of sludge intercepted by the filter in one cycle is the difference between influent and effluent SS multiplied by the water production per cycle. The effluent is calculated as 0 (simplified; actual 5~10 mg/L), and the influent is taken as the upper limit specified in the standard, 20 mg/L:

Cycle interception amount M = W × C₀ = W × 0.020 (kg/m²)

Converted to filter medium volume: M ÷ filter layer thickness L = solids loading capacity (kg/m³)

Substituting the four W values and two filter layer thicknesses from Table 3 yields Table 5. This table translates "the filtration rate and cycle specified in the standard" into "the solids loading capacity implied by the standard"—and when converted based on a 1.2 m filter layer, it falls within 1.00~3.20 kg/m³, exactly the second row in Table 4 (when converted based on 1.5 m, it drops to 0.80).

Table 5 Solids loading back-calculated from the specified range, compared with three sets of measured values
Cycle Water Production W (m³/m²)Cycle Interception M (kg/m²)÷1.2 m Filter Bed÷1.5 m Filter BedReference
60 (v=5, T=12)1.201.00 kg/m³0.80 kg/m³Falls on the upper edge of the operating threshold
117 (median)2.341.95 kg/m³1.56 kg/m³—
192 (v=8, T=24)3.843.20 kg/m³2.56 kg/m³Exceeds the operating threshold by 3 times
465 (measured, SS based on 20)9.307.75 kg/m³6.20 kg/m³Consistent with measured 5.5~7.8
330 (=5.5×1.2÷0.020)6.605.50 kg/m³4.40 kg/m³Back-calculated from 5.5, a verification row

The last two rows of Table 5 are closed: multiplying the measured ultimate capacity 5.5 kg/m³ by 1.2 m gives 6.6 kg/m², and dividing by 20 mg/L back-calculates exactly the cycle water production of 330 m³/m²; while the Jinan measurement is 465 m³/m², corresponding to a 1.5 m filter bed, yielding 6.2 kg/m³, which falls between 5.5~7.8.The numbers from three independent sources agree within the same equation, showing that the relationship "cycle water production = solids loading ÷ influent SS" is real, not a coincidence.

So now we can answer the question in the title.

Write the equation in reverse order: v = W ÷ T = (solids loading × filter bed depth) ÷ (influent SS × cycle). Filtration rate is not selected; it is derived by division. For every halving of influent SS, the cycle water production that the same filter media can sustain doubles, and the filtration rate can be raised by one step. In water treatment plants, influent turbidity is typically only a few NTU and SS is in the single digits, so 8~10 m/h can be used; in wastewater treatment plants, secondary clarifier effluent is 10~20 mg/L, so only 5~8 m/h can be used. The 3 m/h difference in between all comes from those ten-plus milligrams in the influent.

This also explains one of the most common things on site: for a filter designed at 5~8 m/h, once influent SS surges from 20 to 35 mg/L, the cycle water production drops to 57% of the original at 1/SS—the median 117 m³/m² becomes 66.9 m³/m². With the filtration rate held unchanged at 6.5 m/h, the cycle shortens from 18 h to 10.3 h, already falling below the lower limit in the standard of 12 h; if the filtration rate is raised to 8 m/h in operation to maintain water throughput, the cycle is only 8.4 h, requiring nearly three backwashes per day. The operator's first reaction is "the filter is clogged," but in fact the denominator has been changed—same filter, same batch of media, only 15 milligrams more in the influent.

VI. One backwash 5.025 m³/m², of which 1.95 is unfiltered raw water

The other account of the filter lies in backwashing. Article 7.11.8 of GB 50014—2021 provides a complete set of intensity and duration values for the V-type filter, each of which is a range; taking the median to calculate the unit-area water volume of one backwash:

Table 6 Water Volume Breakdown of a Single Backwash (Based on Median Values of Standard Parameters)
StageIntensityDurationWater Volume (L/m²)Water Source
Air Scour Only13~17 L/(m²·s), take 152~4 min, take 30— (air only)
Air-Water Combined ScourAir 15 + Water 3.5 L/(m²·s)3~4 min, take 3.5735Filtered Water
Water Scour Only4~8 L/(m²·s), take 65~8 min, take 6.52340Filtered Water
Surface Sweep2~3 L/(m²·s), take 2.5Full duration 13 min1950Water to Be Filtered (Raw Water)
Total—13 min5025Filtered Water 3075 (61.2%) + Raw Water 1950 (38.8%)
Water Volume Breakdown of a Single Backwash
Figure 3 A single backwash 5.025 m³/m². The two dark blue segments are filtered water (3.075), and the orange segment is the water to be filtered used for surface sweep (1.95)—it enters from the V-shaped trough, sweeps across the filter media surface, and goes directly into the drainage trough, without passing through the 1.2 m-thick filter bed at any point.

That 1.95 m³ of water is what this section is really about. Surface sweep is not backwashing. Its function is to push the sludge layer floating on the filter media surface, which has been lifted by the air and water, toward the drainage trough, preventing the sludge from being drawn back into the filter bed. For this action, the V-shaped trough must maintain inflow throughout the entire backwash—GB 50013—2018 Article 9.5.33 requires an adjustable weir plate for each cell; in practice, this is achieved by means of the inlet opening in the middle that is not closed, setting the gate to the position where "the inflow equals the water consumption for surface sweep." This stream of water comes out of the sedimentation tank, enters the V-shaped trough, sweeps the surface once, and is then discharged.

So nearly 40% of a backwash water stream is "water that has been half-treated and then dumped." In the energy account, it is the upstream cost of coagulation, sedimentation, and pumping; in the discharge account, it means stirring sludge that has already settled back into the water. This has not gone unnoticed in engineering practice: the Shenzhen Bijiashan Water Plant returns the supernatant from backwash sludge discharge water to the raw water distribution well and sends the bottom sludge to an equalization tank, precisely to recover this portion. The plant has 8 V-type sand filter cells, a cycle of 36 h, and backwash drainage per cell of 400 m³/time (including backwash emptying water), with a water consumption rate of 1.6%; the flip-plate carbon filter has 8 cells, a cycle of 48 h, 510 m³/time per cell, and a water consumption rate of 1.45%. Back-calculating the sand filter: 400 ÷ 1.6% = 25000 m³ cycle water production, ÷36 h = 694 m³/h flow per cell; if a single cell is 116 m², the filtration rate is exactly 6.0 m/h—falling in the middle of the drainage-side range 5~8.

VII. The denominator of the water consumption rate is calculated, not measured

In the 1.6% above, the denominator is "cycle water production," and in most plants this quantity has no meter reading and can only be calculated. This creates room for discretion: with the same set of backwash parameters (5.025 m³/m²), the water consumption rate can be 2.62% or 8.38%.

Table 7 With the same set of backwash parameters, the water consumption rate varies 3.2 times with v×T
Filtration Rate (m/h)Cycle (h)W (m³/m²)Water Consumption Rate (including surface wash)Water Consumption Rate (filtered water only)
512608.38%5.12%
612726.98%4.27%
812965.23%3.20%
5241204.19%2.56%
6241443.49%2.14%
8241922.62%1.60%

In Table 7, 8.38% and 2.62% differ by 3.2 times, yet the amount of water used for the two backwashes is exactly the same; the difference lies entirely in the denominator. This explains the three seemingly contradictory figures in the literature:

  • Zhang Wanyou 2007: V-type fiber filter, filtration rate 25 m/h, self-use water consumption "about 1% of the periodic water production". 25 m/h × 20 h (period estimated at 20 h) = 500 m³/m², 1% is the backwash water of 5 m³/m² — corresponding to 10 L/(m²·s) flushing for 8 min.
  • Jinan Pilot Test: filtration rate 20 m/h, period 23 h, W = 460, water consumption rate 3%. Back-calculated according to its process (water wash 4 min + air-water 14 min + water wash 2 min, water intensity 10 L/(m²·s), sweep wash 2 L/(m²·s), full duration 20 min): 2400 + 8400 + 1200 + 2400 = 14400 L/m², 14.4 ÷ 460 = 3.13%, consistent with the reported 3%.
  • Chen Jinzhao 2015: V-type fiber filter, influent SS<20, COD<30, turbidity<12 NTU, SS and turbidity removal rate above 80%, COD removal 15%~20%, fiber filter media pollutant holding capacity 7.8 kg/m³, backwash water consumption only 2.7% of the filtered water volume, capable of backwashing out more than 90% of the intercepted pollutant load.
The conclusion must be stated clearly: these three numbers (1%, 2.7%, 3%) cannot be compared directly. The pollutant holding capacity of fiber filter media is higher than that of quartz sand, and the backwash intensity is also higher (10 L/(m²·s) versus 6), so the water volume per backwash can be 3 times that of quartz sand; the reason its water consumption rate is still low is that the filtration rate is high, W is large, and the denominator is enlarged. Therefore, "low water consumption rate" does not equal "water saving"; it may simply mean "high filtration rate". The truly comparable quantities are "how many m³/m² per backwash" and "how many m³/m² produced per cell per period". Write both out, and the third is what gets calculated.

VIII. Filtration rate has four names, but the standard only issues two

Back to v. This single letter corresponds to at least four quantities in actual documents:

Table 8 Four filtration rates: definitions, applications, and who provides the values
NameDefinitionApplicationSource of Value
Design (normal) filtration rateAverage filtration rate when all cells are in operationDetermines total filtration areaWater supply 8~10; drainage 5~8
Forced filtration rateFiltration rate of the remaining cells when one cell is under maintenance or backwashingVerification, area unchangedWater supply 10~13; no provision on the drainage side
Average filtration rateDaily average including backwash downtimeAccounting for periodic water productionTo be calculated: v×T effective/T total
Peak filtration rateInstantaneous filtration rate at peak flowVerification of effluent guarantee rateDetermined by flow variation coefficient

Of the four, only the first two have values in the standards, while the latter two are often mixed into the first two in use. A real project's approach can serve as an example: for the deep-bed denitrification filter of an industrial park wastewater treatment plant, with a media layer of 2.4 m and a head loss of less than 2.0 m, the average filtration rate 3.66, peak filtration rate 5.34, and forced filtration rate 4.18 m/h were given side by side—three values written together, so no one can misread them.

The gap on the drainage side deserves separate mention. Article 7.11.8 of GB 50014—2021 specifies a design filtration rate of 5~8 m/h, with no mandatory filtration rate verification clause; Article 9.5.8 of GB 50013—2018 on the water supply side explicitly requires "design according to normal filtration rate and verify with mandatory filtration rate." This difference has consequences during operation:

Table 9 Forced Filtration Rate during One-Cell Maintenance (vforced = v × n ÷ (n−1))
Number of Cells nv=5 m/hv=6 m/hv=8 m/hHigher than Normal Filtration Rate
46.678.0010.67+33.3%
56.257.5010.00+25.0%
66.007.209.60+20.0%
85.716.869.14+14.3%

4 cells, designed at the upper limit of 8 m/h; during maintenance of one cell, the remaining three cells must run at 10.67 m/h, 33% higher than the design value, which has already exceeded the upper limit of 8 m/h given on the drainage side itself. This figure has not yet exceeded the upper limit of the forced filtration rate 13 m/h on the water supply side, so it does not count as a "violation", but it means that the effluent SS will inevitably rise during that period—and the acceptance report will not contain data for this cell, because acceptance was carried out with all cells in operation. Article 9.5.3 of GB 50013—2018 requires that the number of filter cells "shall not be less than 4, except for valveless filters and siphon filters"; the fewer the cells, the heavier the penalty of this 1/(n−1).

Criterion: Whenever a code only provides a "normal value" and no "check value," you must write out the check formula yourself and run it. Forced filtration rate of drainage-side filters, standby rate of backwash pumps, and failure conditions of dosing equipment all fall into this category. The absence of a check does not mean a check is unnecessary—it only means the responsibility for checking has shifted from the code to the design specification, and if the specification does not state it, no one will ask about it during acceptance.

IX. The Three Units of Intensity: 1 L/(m²·s) = 3.6 m/h

Backwash intensity is the quantity with the most confusing units in the filter chapter. The same thing has three ways of being written, and the third way makes people mistakenly think it is the filtration rate:

Table 10 Three units of backwash intensity, with an intuitive comparison to filtration rate
NotationConversion Relationship4~8 (Water Backwash)13~17 (Air Backwash)Water Backwash ÷ Filtration Rate (5~8)
L/(m²·s)Baseline4~813~17—
m³/(m²·h)×3.614.4~28.846.8~61.23.6~5.8 times
m/h×3.6 (same value as the row above)14.4~28.846.8~61.2Same as above, but the dimensions are identical, making them very easy to confuse

There is only one conversion factor: 1 L/(m²·s) = 3.6 m³/(m²·h) = 3.6 m/h. Therefore, the upper limit of water backwash 8 L/(m²·s) is 28.8 m/h, which is 3.6~5.8 times the filtration rate during filtration (5~8 m/h); air backwash 15 L/(m²·s) converts to 54 m/h, which is 7~11 times the filtration rate. This multiple is the basis for designing backwash pumps and blowers, and is also the first ruler for judging whether "the pump is undersized."

Conversely, Article 7.11.11 of GB 50014—2021 specifies the water flushing intensity for Activated Carbon filters as 39.6~46.8 m³/(m²·h), with an expansion rate of 15%~20%; converted back to the first unit, that is 11~13 L/(m²·s)—nearly double the 4~8 for quartz sand. Because the density of carbon is only half that of quartz sand (1.4~1.6 versus 2.60~2.65 g/cm³), the same expansion rate requires a larger water volume. This is the role of the term "expansion rate": it is not a companion to the intensity, but the criterion for the intensity.

One calculation makes it clear. With a filter bed of 1.2 m and an expansion rate of 20%, the expansion height is 0.24 m; Article 9.5.36 of GB 50013—2018 requires the top surface of the flushing drainage trough to be 500 mm above the surface of the filter medium layer, with a margin of 0.26 m. If the filter bed takes the upper limit 1.5 m and the expansion is 0.30 m, the margin is only 0.20 m. Article 9.5.24 also has another sentence: "The total plane area of the flushing drainage trough shall not be greater than 25% of the filter area, and the distance from the filter medium surface to the bottom of the sand-washing drainage trough shall be equal to the expansion height of the filter layer during flushing."—This sentence locks the trough bottom position and the expansion rate to the same number; if the trough bottom is set wrong by 5 cm, then during flushing either sand will be carried away or a layer of sludge will remain unwashed.

X. Filter Medium Grading: d10, K80 and K60, L/d10

The filter medium is the only component of the filter that is "procured to specification," and the only one that can be replaced on site. Its specification is governed by three numbers:

Table 11 Three indicators of filter media gradation, and that easily interchangeable coefficient
IndicatorDefinitionSpecification requirementWhy it matters
Effective size d10Particle size corresponding to 10% passing on the sieving curveUniformly graded coarse sand 0.9~1.2 mmDetermines filtration precision and the rate of head loss increase
Uniformity coefficientK80 = d80/d10; K60 = d60/d10Uniformly graded coarse sand K80 mostly 1.2~1.4Determines whether hydraulic classification occurs after backwashing and whether fine particles float up
L/d10Filter bed thickness ÷ effective sizeFine sand and dual media >1000; coarse sand >1250Ensures that a "thick bed" compensates for the interception loss of "coarse grains"

The second indicator has a trap, and it is purely arithmetic: K60 and K80 are two different numbers, and K60 ≤ K80 always holds (because d60 ≤ d80, with the same denominator). For the same batch of filter media, judging by K60 may "satisfy less than 1.6", while judging by K80 may "not satisfy less than 1.4". Such mixed usage appears in the retrieved technical modification materials: one comparison table writes the "filter media uniformity coefficient" column as "K80 less than 1.25", while another column gives the standard value as "K60 less than 1.6"; the two columns are juxtaposed but use different scales. This is not just a typo—it can cause the same batch of sand to be judged qualified during procurement acceptance and unqualified during technical modification review.

Criterion: whenever you see the four words "non-uniformity coefficient," first ask whether it is K80 or K60. Both numbers are legitimate and both are in use, but they are not interchangeable; applying the acceptance threshold for K60 (1.6) to K80 amounts to relaxing the standard; conversely, it amounts to rejecting good product for nothing. This rule belongs to the same family as 11-09 "the denominator of B/C is five days"—the same term, two definitions, opposite directions.

The third indicator, L/d10, is the one most easily overlooked. Clause 9.5.5 of GB 50013—2018 writes it as a hard constraint: fine sand and dual-layer filter media greater than 1000, coarse sand greater than 1250. The meaning is that the coarser the filter media, the thicker the filter layer must be—coarse grains have a smaller specific surface area, fewer opportunities for collision and adsorption per unit thickness, and can only compensate by being thicker. A technical modification document describes the real situation on site: the original design d10 was 1.0~1.25 mm, the filter layer 1100 mm, L/d10 = 1000, which according to the coarse sand requirement should be greater than 1250, not satisfied; the support layer 2~8 mm also exceeds the specification's 2~4 mm. Because the elevation of the original tank is limited, the water depth above the sand surface can only be 1.1 m (the specification requires not less than 1.2 m); the choice in the technical modification is to "sacrifice the former and keep the latter"—keep the filter layer thickness 1.2 m, sacrifice the 0.1 m of water depth above the sand surface, on the grounds that the effluent weir crest elevation after filtration is relatively high and the risk of negative head is low.

XI. Head Loss: 2.0~2.5 m and 0.2~0.4 m Are Not the Same Thing

There are two figures for the head loss of a filter, differing by a factor of 5~12, and they are often placed side by side in the same comparison table:

Table 12 Head loss and filtration rate of six basin types: the difference lies not in "advancement" but in "structure"
Basin TypeFiltration Rate (m/h)Head Loss Before BackwashFilter Bed CharacteristicsBasis
V-type Filter (uniformly graded coarse sand)5~82.0~2.5 m1.2~1.5 m deep bed, full-depth interceptionGB 50013 9.5.26 / GB 50014 7.11.8
Siphon Filter—1.5 mSingle-layer fine sand, surface interceptionGB 50013 9.5.38
Gravity Valveless Filter—1.5 mSingle-layer fine sandGB 50013 9.5.43
Flap Valve Filter—2.0~2.5 mDeep bedGB 50013 9.5.46
Rotary Disc Filter (filter cloth/mesh)8~100.2~0.4 mThin disc surface, no filter bed depthGB 50014 7.11.9
Activated Carbon Filter7~120.4~1.0 mCarbon layer 3~4 m, adsorption-dominatedGB 50014 7.11.11

The head loss of a rotary disc filter is only 0.2~0.4 m, not because it is "more advanced", but because it has no filter bed. The filter cloth or mesh is a medium layer tens of micrometers thick, and water passing through it loses only ten to several tens of centimeters; whereas a V-type filter requires water to pass through 1.2~1.5 m of sand, where the tortuous pores and particle collisions along the path all consume energy. The two are therefore not comparable: the 0.2~0.4 m of the rotary disc buys "surface screening", while the 2.0~2.5 m of the V-type buys "depth interception"—the latter has an order of magnitude higher solids loading capacity, while the former has an order of magnitude lower footprint and investment. Two combinations are common in engineering practice: series connection (rotary disc upstream to guarantee SS, sand filter downstream to guarantee precision) and substitution (using rotary discs directly in place of sand filters when space is tight).

But the head loss figure is not just for equipment selection; it is the upper limit for hydraulic profile design. The elevation of the filter effluent weir crest = filter media surface elevation + sand surface water depth − head loss. If designed according to 2.0 m but actually operating at 2.4 m, the effluent weir will be insufficient, negative pressure will occur in the upper filter layer, dissolved gases will precipitate out, and the filter layer will be penetrated by gas bubbles—this is "negative head." There are only three preventive measures, and all are at the design stage: reduce filtration rate, raise the post-filtration effluent outlet elevation, increase sand surface water depth. All three require civil works changes; none can be remedied during the operation period.

XII. The Denominator of Removal Rate, and a Nonexistent SS Standard

Finally, back to the indicators themselves. The acceptance indicator for filters is usually "effluent SS ≤10 mg/L" (GB 18918—2002 Class I-A) or "quasi-Class IV." There are two pitfalls here.

Table 13 The same filter, four influent/effluent combinations
Influent SSEffluent SSRemoval RateCompliance Judgment Against Limit 10
20 mg/L575.0%Compliant (margin 50%)
10 mg/L550.0%Compliant (margin 50%)
20 mg/L1050.0%Just compliant (zero margin)
30 mg/L1066.7%Just compliant (zero margin)

"Removal rate 75%" and "removal rate 50%" can come from the same filter and the same effluent value, with the only difference being the influent. Therefore, filter acceptance must report both the absolute influent and effluent values; reporting only the removal rate conveys no information. This is most clearly seen in the literature: the Jinan pilot test reported "SS removal rate above 70%", Chen Jinzhao reported "above 80%", and Zhang Wanyou reported "93.04%" — the denominators of these three figures are respectively secondary clarifier effluent, secondary clarifier effluent, and on-site water from a certain plant, and none is more advanced than another.

The second pitfall is even tougher: GB 3838—2002 does not include Suspended Solids (SS) as an item. Among the 24 basic items in Table 1 of this standard (water temperature, pH, Dissolved Oxygen (DO), permanganate index, COD, BOD₅, ammonia nitrogen, Total Phosphorus (TP), Total Nitrogen (TN), copper, zinc, fluoride, selenium, arsenic, mercury, cadmium, hexavalent chromium, lead, cyanide, volatile phenols, petroleum substances, anionic surfactants, sulfide, fecal coliform), there is no SS, and it is also absent from the 5 supplementary items in Table 2 and the specific items in Table 3. Therefore, the statement "effluent SS meets Surface Water Class IV" cannot be matched to any clause in the standard system—what it actually corresponds to is a separate figure added in a local standard or in the project's environmental impact assessment approval (commonly 10 mg/L). If you copy "meets Surface Water Class IV" into an acceptance report, you will be unable to answer when the reviewer asks "what is the SS limit for Class IV?" Criterion: whenever you see "a certain parameter meets Surface Water Class X," first check whether that item exists in Table 1 of GB 3838; if it does not, you must trace it to a local standard or approval document.

XIII. Comparison of the Filter Family

Table 14 Selection comparison of five types of granular filter media/thin-layer filtration (filtration rate and backwash parameters taken from the drainage side of GB 50014—2021)
Basin TypeFiltration RateCycleBackwashSolids Holding CapacityApplication and Limitations
V-type Filter (uniform coarse sand)5~812~24 hAir + air-water + water + surface sweep5.5~7.8Mainstay of advanced treatment; requires upstream sedimentation to bring SS below 20; moderate footprint, head loss 2.0~2.5 m
Dual-media Filter (anthracite + quartz sand)5~10—Air scour 15~20 + water scour 6.5~104~6Coarse on top, fine at bottom, high solids holding capacity; low density of anthracite requires prevention of media loss; backwash in two stages of intensity
Single-layer fine sand4~6—Air scour 15~20 + water scour 8~103~5High precision, low solids holding capacity; suitable for polishing at low SS; highest water scour intensity (fine sand requires greater expansion)
Fiber Filter20~4012~47 hWater + air-water + water + surface sweep, 10/40/2 L/(m²·s)5.5~12.52High filtration rate, small footprint; large backwash water volume (14.4 m³/m²), media service life and entanglement failure are O&M challenges
Disc Filter8~10—Disc surface backwash, water pressure 7~15 m (filter cloth)—Head loss only 0.2~0.4 m, small footprint; thin-layer screening, no deep interception, requires reliable upstream sedimentation

The Fiber Filter column in Table 14 best illustrates that "parameters cannot be borrowed across basin types": its filtration rate of 20~40 m/h is 3~5 times that of the V-type filter, which appears extremely efficient; however, its backwash requires 14.4 m³/m² per cycle, nearly 3 times that of the V-type, and its air scour intensity of 40 L/(m²·s) is 2.7 times that of the V-type. The footprint savings gained from the high filtration rate are partly offset by higher backwash water volume and more delicate filter media. What selection must calculate is "net water production rate", not "filtration rate".

XIV. Engineering Cases and Eight Criteria

Putting publicly available engineering data together, the position of the filter section in real projects becomes clear: it almost never appears alone, always appearing in pairs as "sedimentation + filtration," and the weight of the indicators it bears is growing.

Table 15 Filter locations and data in six publicly disclosed projects
ProjectCapacityPosition of the filter in the process flowKey data
Upgrading of a wastewater treatment plant in Suzhou Industrial Park20 万 m³/dBAF (DN+CN) + high-efficiency sedimentation tank + V-type filter + UV/sodium hypochloriteOriginally AAO + cloth filter + UV; upgraded to Surface Water Class IV standard
Renovation and expansion of a plant in Suzhou (Bardenpho)—Bardenpho + high-efficiency sedimentation tank + V-type filter + combined disinfectionCOD/BOD₅/SS/ammonia nitrogen/TN/TP removal rates 96.3/99.2/96.6/98.6/87.0/98.4%; cost 0.658 元/m³
Wastewater treatment plant in an industrial park—Sulfur-based autotrophic parallel heterotrophic deep-bed denitrification + ozonation + high-efficiency sedimentation tankMedia layer 2.4 m; average/peak/forced filtration rate 3.66/5.34/4.18 m/h; head loss <2.0 m
Wastewater treatment plant in a chemical industrial park in Nantong—Ozonation + hydrolysis acidification + A/O + secondary sedimentation + Fenton + high-density clarification + V-type filterComprehensive cost reduced by 2.5 元/m³; the V-type filter can later be converted into a denitrification filter
Shenzhen Bijiashan Water Treatment Plant (water supply)—V-type sand filter 8 cells + flip-plate carbon filter 8 cellsSand filter cycle 36 h, single cell 400 m³/cycle, water consumption rate 1.6%; carbon filter 48 h, 510 m³/cycle, 1.45%
Zhuhai Baiteng Water Quality Purification Plant8 万 m³/dA²O oxidation ditch + high-efficiency sedimentation tank + precision filter2023 年 6 月 passed the completion environmental protection acceptance; effluent better than Class 1A

The Nantong case deserves a closer look: it wrote into its conclusions that "the existing V-type filter can later be converted into a denitrification biofilter." This means the filter tank structure is generic; what changes is what goes inside—replace the media with biological ceramsite, add carbon source dosing, and change air scouring to backwashing only without aeration, and a physicochemical filter becomes a biofilter. This also explains why the elevation and number of cells of the filter must be reserved in one go: the tank structure is civil works, and the conversion window comes only once.

Eight key takeaways:
  1. Filtration rate is not a free parameter.v = solids loading × filter bed depth ÷ (influent SS × cycle). First set the influent SS and target cycle; the filtration rate is derived.
  2. Filtration rate and cycle have only one degree of freedom.The product W = v×T is the capacity; changing v only changes "how often to backwash."
  3. Solids loading has three values, differing by 17~25 times.Operational threshold 0.5~1.0 (head loss reached first), code-based back-calculation 1.0~3.2, ultimate capacity 5.5~12.52 (before breakthrough). Which one to use depends on which question you are answering.
  4. The premise of "the code specifies 5~8" is "influent SS less than 20."When the premise does not hold, the cycle is reduced proportionally, but the filtration rate cannot be increased proportionally.
  5. In a single backwash of 5.025 m³/m², 1.950 is filtered water.Surface sweep water does not pass through the filter bed and is discharged directly; it accounts for 38.8% of the backwash water.
  6. The denominator of the water consumption rate is calculated.The same set of backwash parameters can be 2.62% or 8.38%; "low water consumption rate" may simply mean "high filtration rate."
  7. There is no mandatory filtration rate clause on the drainage side.4 cells are designed at 8 m/h; during maintenance 10.67 m/h (+33%), and there is no acceptance data for the effluent during this period.
  8. Head loss is a civil engineering limit, not a selection parameter.If 2.0~2.5 m is set wrong, it can only be remedied by reducing the filtration rate during operation; all three preventive measures are at the design stage.

References

  1. National Standard of the People's Republic of China. Standard for Design of Outdoor Wastewater Engineering GB 50014—2021: Article 7.11.8 (influent SS of filter, filtration rate and backwashing parameters of V-type filter, filtration cycle), Article 7.11.9 (disc filter), Article 7.11.11 (activated carbon adsorption tank) [S]. Beijing: China Planning Press, 2021.
  2. National Standard of the People's Republic of China. Standard for Design of Outdoor Water Supply Engineering GB 50013—2018: Articles 9.5.3, 9.5.5, 9.5.8, Table 9.5.9, Articles 9.5.13, 9.5.24, 9.5.26~9.5.36, 9.5.38, 9.5.43, 9.5.46 and article explanations [S]. Beijing: China Planning Press, 2018.
  3. National Standard of the People's Republic of China. Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant GB 18918—2002: Table 1 Maximum allowable discharge concentration of basic control items (SS of Grade I-A is 10 mg/L) [S]. Beijing: China Environmental Science Press, 2002.
  4. National Standard of the People's Republic of China. Environmental Quality Standards for Surface Water GB 3838—2002: Table 1 Basic items (24 items, excluding suspended solids), Table 2 Supplementary items, Table 3 Specific items [S]. Beijing: China Environmental Science Press, 2002.
  5. Industry Standard for Urban Construction of the People's Republic of China. Filter Media for Water Treatment CJ/T 43—2005[S]. Beijing: Standards Press of China, 2005.
  6. Chen Jinzhao, Cai Kuifang. Design and operation of V-type fiber filter in advanced treatment of municipal wastewater[J]. Industrial Water & Wastewater, 2015(4): 67-69.
  7. Zhang Wanyou, Zhou Ding, Wang Xusheng, Pan Tingkai. Design and operation of V-type fiber filter[J]. Industrial Water Treatment, 2007, 27(12): 80-82.
  8. Experimental study on advanced treatment process of V-type high-efficiency fiber filter for wastewater[D]. Master's Thesis (test water source: effluent from secondary sedimentation tank of Jinan No.2 Water Purification Plant).
  9. Guan Yongnian. Application of BAF + high-efficiency sedimentation tank + V-type filter in high-standard upgrading and reconstruction of wastewater treatment plant[J]. China Water & Wastewater, 2023, 39(14): 66-70.
  10. Application of Bardenpho + high-efficiency sedimentation tank + V-type filter process in reconstruction and expansion of wastewater treatment plant[J]. Water Treatment Technology, 2023, 49(11): 150-156.
  11. Application of sulfur autotrophic parallel heterotrophic deep-bed denitrification filter + ozonation + high-efficiency sedimentation tank process in upgrading and reconstruction of a wastewater treatment plant in an industrial park[EB/OL]. HC Water Industry Network.
  12. Phased cost reduction and efficiency improvement reconstruction of a wastewater treatment plant in a chemical industrial park in Nantong[J]. (Research Support Project of Jiangsu Environmental Protection Group Nantong Co., Ltd. JSEPNT-KY-2023-002).
  13. Experimental study on optimized water conservation of Shenzhen Bijiashan Water Plant[R]. China Water Network Paper Database.
  14. Technical modification of filter media and structure (including negative head prevention and L/d10 recheck)[J]. Southwest Water & Wastewater, 2021, 43(2).
  15. A filter backwashing system, filter system and backwashing method: CN115364536B[P]. (Suspended solids accumulation threshold 0.5~1.0 kg/m³, cycle 36~72 h).
  16. Doumen District, Zhuhai City. 2023 年-degree environmental management status assessment report of Baijiao Science and Technology Industrial Park, Zhuhai National High-tech Industrial Development Zone[R]. 2024.
  17. Article explanations of Standard for Design of Outdoor Wastewater Engineering GB 50014—2021: Section 7.11 Advanced and Reclaimed Treatment[S].
  18. Water Supply and Drainage Design Manual (Volume 3, Urban Water Supply): Filter chapter[M]. Beijing: China Architecture & Building Press.
  19. He Wei, He Chao. Application of combined biological aerated filter in upgrading of wastewater treatment plant to quasi-Class IV standard[J]. China Water & Wastewater, 2021, 37(8).

All numerical values in this paper are taken from the above public standard clauses, journal papers and government acceptance documents; any intermediate values derived by back-calculation from the clauses (such as back-solved solids loading, water consumption rate, forced filtration rate) are marked with formulas and prerequisite assumptions in the main text so that readers can recalculate them independently. The figures are locally plotted according to the formulas and are not engineering measured curves.