Reverse Osmosis: 75% is a concentration factor of 4, not 1.33; with 80%, concentrate volume drops by 20% while salt remains unchanged
The previous article discussed the meter at the discharge outlet and how its error gets amplified exponentially. This article moves one step upstream to discuss the most frequently cited parameter in membrane systems—recovery rate. It looks like just a percentage, but it actually determines four things at once: how concentrated the concentrate is, how much osmotic pressure the membrane surface must withstand, how large the downstream evaporator needs to be, and whether the produced water is still clean. These four things do not point in the same direction, so "increasing the recovery rate" is never simply a good thing or a bad thing—it depends on which one gives out first.
The definition of recovery rate is only one line: permeate flow divided by feed flow. The trouble is that "feed flow" has three candidates, "concentrate" has two interpretations, and the "concentration factor" derived from it can yield four different values across four sets of materials—4.00, 3.94, 3.89, and the 3.20 actually given by the bottle of concentrate on site. All four numbers are legitimate. The difference is not in the arithmetic, but in which quantity you hold constant.
1. Recovery rate is not a setpoint; it is the quotient of flows
First, something that is most easily mistaken for a fault on site: the recovery rate changes by itself. It is not a knob that can be turned to 75%; it is permeate flow divided by feed flow. Reverse Osmosis permeate flow varies with water temperature, and the empirical value is that for every 1 ℃ decrease, permeate flow drops by about 3%. From 25 ℃ to 10 ℃, the permeate coefficient falls to 0.633. If the feed flow does not change and the pressure does not change, the original 75% recovery rate will become 47.5% by itself—not because the membrane is damaged, not because the antiscalant has failed, but simply because the water is colder, the viscosity is higher, and the permeation is lower.
Conversely, if 75% must be maintained, then the feed must be reduced from 100 to 63, so that permeate and feed shrink in the same proportion. At this point the recovery rate is preserved, but the permeate flow drops by 37%. These two responses look completely different in the operating log: one says "insufficient recovery rate, suspect Membrane Fouling," and the other says "decreased permeate flow, suspect Membrane Fouling"—but both are actually water temperature.
So when looking at the recovery rate number, the first question to ask is not "how much," but "at what water temperature and what feed flow was it measured?" Clause 7.3.11.5.3 of HJ 579—2010 gives the "raw water recovery rate"—a capability value under the design conditions at rated permeate flow, not a measured ratio at any given moment. The 75% measured during acceptance and the 47% in the winter log can both be true at the same time.
2. 1.33 and 4.00: two interpretations of the same 75%
Substituting 75% into three different formulas yields three numbers that are all "correct":
- Permeate accounts for 75% of feed, so concentrate accounts for 25% of feed—this is the water volume share;
- Feed is 1/0.75=1.33 times permeate—this is the water volume ratio, also called the "feed ratio";
- Concentrate concentration is 1/(1−0.75)=4 times the feed concentration—this is the concentration factor.
All three numbers are born from 75%, but their dimensions are completely different. The consequence of treating 1.33 as the concentration factor is calculable: if concentrate salinity is estimated at 1 330 mg/L, the actual value is 4 000 mg/L, three times lower. If antiscalant is dosed according to this number, the dosage is only one third of what it should be; if silica is checked against this number, the check table says "unsaturated" while precipitation has already begun on the membrane. This type of error does not show up in the calculation sheet, because that column in the calculation sheet is called "concentration factor," and the number filled in looks like a factor.
| Recovery Rate | Concentrate as % of Feed | Feed/Permeate (Water Volume Ratio) | Concentration Factor 1/(1−R) | Corrected for 98% Rejection | Salt in Permeate as % of Feed |
|---|---|---|---|---|---|
| 50% | 50% | 2.00 | 2.00 | 1.97 | 2.8% |
| 60% | 40% | 1.67 | 2.50 | 2.45 | 3.1% |
| 70% | 30% | 1.43 | 3.33 | 3.25 | 3.4% |
| 75% | 25% | 1.33 | 4.00 | 3.89 | 3.7% |
| 80% | 20% | 1.25 | 5.00 | 4.84 | 4.0% |
| 85% | 15% | 1.18 | 6.67 | 6.41 | 4.5% |
| 90% | 10% | 1.11 | 10.00 | 9.54 | 5.1% |
| 95% | 5% | 1.05 | 20.00 | 18.80 | 6.3% |
The last column in the table deserves a separate look: when the feed salt content is 1 000 mg/L, the permeate at a recovery rate of 75% is 37 mg/L, and at 90% it is 51 mg/L.Each step up in recovery rate makes the permeate a little dirtier, because the average concentration at the membrane surface is rising. This column will be used again in Section 9.

III. Three Recovery Rates: System, Stage, and Element — Chained Together by Multiplication
For a two-stage Reverse Osmosis / RO system, there are three "recovery rates" on paper, and their denominators are not the same water:
- System recovery rate = permeate/fresh feed water; this is the number reported externally;
- Stage recovery rate = permeate of this stage/feed water of this stage; the feed water of the second stage is the concentrate of the first stage;
- Element recovery rate = permeate of a single membrane element/feed water of a single membrane element, usually only 10%~15%.
For stages in series, the system recovery rate is calculated by multiplication, not addition: system recovery rate = 1−(1−R₁)(1−R₂). For example, with a first stage of 60% and a second stage of 37.5%, the system is 75.0%; adding the two numbers gives 97.5%, which is a number that does not exist. Conversely, from 60% to 75%, the second stage only needs 37.5%—this is the essence of a tapered array: the final stage produces less permeate and passes more water, trading permeate rate for membrane surface velocity.
| Name | What Water Is the Denominator | Typical Value | Common Mistake |
|---|---|---|---|
| System Recovery Rate | Fresh feed water (excluding recirculation) | Brackish water 75%~80%, seawater desalination 35%~45% | With concentrate recirculation, mistakenly using "flow before membrane" as the denominator, resulting in an underestimated value |
| Stage Recovery Rate | Feed water of this stage (concentrate from the previous stage) | First stage 55%~65%, last stage 30%~40% | Adding the two stage values together, writing 60%+37.5% as 97.5% |
| Element Recovery Rate | Feed water of a single element | 10%~15% | Taking the single-element 15% as the system value, underestimating the membrane area by five times when back-calculating |
| Module (Pre-membrane) Recovery Rate | Flow before membrane = feed + recirculation | 5~15 percentage points lower than the system value | Mixed up with system recovery rate, the two values "don't match" each other |
Here is a fact that can be seen by arithmetic alone: the system recovery rate of a two-stage series system is always less than the sum of the two stages, and as the number of stages increases, the system recovery rate approaches 1 more and more slowly. Three stages at 85%~90% is already a stretch, and beyond four stages the marginal gain is almost zero—because the feed water to the last stage is only a few percent, and no matter how much you squeeze, you can't squeeze out more water. The standard design guidelines state the correspondence between the number of stages and recovery rate very plainly: single stage <50%, two stages <75%~80%, three stages <85%~90%.[1]
IV. The concentration factor has four values, and each difference has its own destination
1/(1−R) is the concentrate concentration when "no salt passes through the membrane at all." A real membrane is not like this; a salt rejection rate of 98% means that 2% of the salt travels along with the water. Taking this 2% into account, the concentrate concentration should be somewhat lower—but "how much lower" depends on whether you write the permeate concentration as 2% of the feed concentration or as 2% of the membrane-surface average concentration:
| Algorithm | Meaning of the formula | Concentrate concentration | Concentration factor | Difference from theoretical value |
|---|---|---|---|---|
| Pure theoretical | All salt remains on the concentrate side | 4 000 mg/L | 4.00 | — |
| Salt passage calculated from feed concentration | Permeate = 2% × feed | 3 940 mg/L | 3.94 | 1.5% |
| Salt passage calculated from membrane-surface average concentration | Permeate = 2% × average feed (1.848 times) | 3 889 mg/L | 3.89 | 2.8% |
| Measured (Total Dissolved Solids) | Sampling and measurement | Depends on site | Depends on site | — |
The difference among the first three numbers is only 1–3 percentage points, which is negligible in engineering terms. What is truly informative is the fourth one: calculating the concentration factor separately for different ions in the same bottle of concentrate. The following set of numbers is an example (feed calcium 62.5, chloride 120, silica 20 mg/L, recovery rate 75%, theoretical corrected value 3.89):
| Item | Influent mg/L | Measured Concentrate mg/L | Apparent Concentration Factor | Lower than 3.89 by | Where the difference went |
|---|---|---|---|---|---|
| Chloride | 120 | 430 | 3.58 | 7.9% | Does not precipitate; can only be attributed to sampling, analysis, or conversion errors |
| Calcium | 62.5 | 200 | 3.20 | 17.7% | 43 mg/L calcium, equivalent to about 107 mg/L as calcium carbonate, deposited on the membrane |
| Silica (dissolved) | 20 | 77 | 3.85 | 1.0% | Not yet polymerized, still in solution |
This criterion has another prerequisite that is easily overlooked: do not use conductivity to calculate the concentration factor. Conductivity and salt content do not have a linear relationship in the high-concentration range (the deviation is obvious above 4 000 mg/L), and it also drifts with temperature and pH; the same bottle of water can differ by several percentage points at a different temperature. The 3.2 or 4.5 calculated from it cannot be attributed. To calculate conservation, use conservative ions.
V. The upper limit is not set by the membrane, but by four salts
The membrane itself is not afraid of concentrated water; what it fears is that certain substances in the concentrated water will saturate first. Each of the four sparingly soluble salts has a boundary of "precipitation once concentrated further." Back-calculating the boundary into recovery rate and taking the smallest one is the recovery rate this system can truly achieve:
| Constraint | Criterion | Back-calculation method | Allowable recovery rate | Which binds first |
|---|---|---|---|---|
| Calcium carbonate (LSI) | Concentrate LSI ≤1.8 (effective upper limit of antiscalant) | Calculate pHs step by step, bisection back-calculation | 95.1% | At 75%, LSI is only +0.45, the loosest |
| Calcium sulfate | Ion product ≤0.8Ksp | R=[1−1/√(0.8Ksp/IP)]×100 | 91.0% | Relatively loose |
| Silica | Concentrate ≤106 mg/L (25 ℃) | R=1−influent silica/saturated silica | 81.1% | This is what binds first in summer |
| Barium/strontium sulfate | Ion product ≤0.8Ksp (Ksp on the order of 10⁻¹⁰) | Same as above | Often negative | Can only rely on antiscalant, not on lowering recovery rate |
| Winter (10 ℃) recalculation | Silica ≤40 mg/L | Same as above | 50.3% | The real ceiling in winter |
Take the minimum: 81% in summer and 50% in winter. This is why the opening of this article says "the design value of recovery rate is not the industry convention of 75%" — it is obtained by back-calculating each of the four salts once and taking the minimum, then correcting once by the coldest-month temperature, and finally leaving a margin of 10~15 points. The industry's "brackish water 75%" is merely the result of these four calculations coincidentally falling into the same range for a typical water quality, not the cause.
VI. Silica: The Same 20 mg/L, 25 ℃ Allows 81%, While 10 ℃ Allows Only 50%
Among the four salts, silica dioxide is the most unreasonable, because its solubility varies too steeply with temperature. The empirical formula given in engineering manuals is saturated concentration=4.39t−3.66 (t is the concentrated water temperature in ℃), while another operation summary gives "25 ℃ not exceeding 100 mg/L, 5 ℃ not exceeding 25 mg/L". The two sources are almost consistent at 25 ℃ (106 and 100), but differ by a margin at 5 ℃ (18.3 and 25). Taking the conservative one does not affect the conclusion: when the temperature drops from 25 to 5, the saturated concentration of silica falls to one-fifth to one-sixth.
| Water Temperature ℃ | Concentrate SiO₂ mg/L (based on CF 4) | Saturation Concentration mg/L | Supersaturation Factor | Allowable Recovery at This Temperature |
|---|---|---|---|---|
| 25 | 80.0 | 106.1 | 0.75 (unsaturated) | 81.1% |
| 20 | 80.0 | 84.1 | 0.95 | 76.2% |
| 15 | 80.0 | 62.2 | 1.29 | 67.8% |
| 10 | 80.0 | 40.2 | 1.99 | 50.3% |
| 5 | 80.0 | 18.3 | 4.37 | Not feasible (negative value) |
This table explains a phenomenon that repeats every winter: a system that runs perfectly well in summer, once the feed 11 月, begins to show rising differential pressure, declining water production, and chemical cleaning that cannot restore the original value; on inspection, the last-stage membrane surface has a glassy layer.This is not an operational error; it is the inevitable result of designing for summer conditions.If the feed silica is 20 mg/L and the water temperature is 10 ℃, there are only two ways to achieve 75%: remove the silica first (softening plus silica removal, or magnesium salt co-precipitation), or reduce the recovery to 50%. A third option is heating—heating the 10 ℃ water to 25 ℃ requires 62.8 MJ per cubic meter, which at 90% thermal efficiency translates to 19.4 kWh; this cost is basically untenable in the face of electricity prices.
7. Calcium Sulfate: What Softening Buys Back Is 10 Points, Not "Better Water Quality"
The calcium sulfate boundary can be written as a single invertible equation; the form in design manuals is:
where 0.8 is the safety factor, Ksp is taken as the apparent solubility product at the ionic strength of the concentrate (not the value in pure water), and Ca and SO₄ are taken as the molar concentrations in the feed. Substituting into the manual's worked example (calcium 2.5 mmol/L, sulfate 3.13 mmol/L, Ksp taken as 2.5×10⁻⁴, 25 ℃) gives 80.2%.[2] This number does not contradict the 91.0% calculated in Table 5 of this article using a different water quality—different ion products give different boundaries, and the same formula applied to different water qualities will naturally give different numbers.
| Condition | Ion Product (mol/L)² | 0.8Ksp/Ion Product | Limit Recovery | Relative to Raw Water |
|---|---|---|---|---|
| Raw Water | 7.83×10⁻⁶ | 25.6 | 80.2% | — |
| Calcium Halved (Sodium Exchange or Lime Softening) | 3.91×10⁻⁶ | 51.1 | 86.0% | +5.8 points |
| Calcium and Sulfate Each Halved | 1.96×10⁻⁶ | 102.2 | 90.1% | +9.9 points |
| Each Reduced to One Quarter | 4.89×10⁻⁷ | 409.0 | 95.1% | +14.9 points |
Note the nature of the numbers in this column: they are the critical values at which "a little more concentration causes precipitation," not values at which "long-term stable operation is possible." In engineering, 10~15 points must still be reserved below them. So the real significance of softening is not "better water quality," but raising the upper limit of recovery for this system from 80 to 90, at the cost of the acid, alkali, and salt used for regeneration, plus a new stream of regeneration waste liquid. This account must be calculated together: whether the water saved by the extra 10 points of recovery can offset the chemicals and waste liquid disposal of the softening system. Most Reclaimed Water Reuse projects can make it balance, while most high-salinity wastewater projects cannot—because the water saved in the latter is not valuable in the first place, and the waste liquid is more expensive.
VIII. Concentrate Recycle: System Recovery Unchanged, Element Recovery Drops by 13 Points
Concentrate recycle is treated in the field as a "master key to improving recovery," but this claim is only half true. Let the fresh feed be 100, the permeate be 80, and the discharged concentrate be 20. Recycle 20 of the concentrate to the front of the high-pressure pump, so the flow before the membrane becomes 120. At this point the two "recoveries" are:
- System recovery = 80/100 = 80.0% — the denominator is the fresh feed, and recycle does not change it;
- Element recovery = 80/120 = 66.7% — the denominator is the flow before the membrane, which recycle has enlarged to 20%.
One and the same action: one number stays unchanged while the other drops by 13.3 points. This clarifies the nature of the statement "recycle improves recovery": turning on recycle alone without changing the discharge leaves recovery completely unchanged, and power consumption will even rise — the extra 20 m³/h of water is pressurized one more time. What it buys is something else: flow velocity; the cost is written in the other two columns — the salinity of the feed before the membrane rises from 1.00 to 1.64 (concentrate at four times the concentration of 20 m³/h is mixed into the feed of 100 m³/h), and the element concentration factor drops from 4.84 to 2.95.
| Item | No Recirculation | Recirculation 20 | Change |
|---|---|---|---|
| Fresh feed m³/h | 100 | 100 | Unchanged |
| Flow before membrane m³/h | 100 | 120 | +20% |
| Permeate m³/h | 80 | 80 | Unchanged |
| Discharged concentrate m³/h | 20 | 20 | Unchanged |
| System recovery | 80.0% | 80.0% | Unchanged |
| Element recovery | 80.0% | 66.7% | −13.3 points |
| Salt content of membrane feed (index) | 1.00 | 1.64 | +64% |
| Element concentration factor (concentrate/membrane feed) | 4.84 | 2.95 | −39% |
| Membrane surface velocity in the last stage | Low | High | Fouling slows down |
The last two rows must be read together: the element concentration factor drops by 39%, but the concentration of the concentrate itself does not change at all (still 4.84 times); only the denominator is lowered—the salt content of the membrane feed is raised. Therefore, the statement "recirculation reduces the scaling risk" is likewise inaccurate: the scaling driving force at the tail end is unchanged, while the average concentration in the middle stages is actually higher. The real benefit lies in the flow velocity: as the membrane surface velocity increases, the concentration polarization coefficient decreases, and colloids and particles are less likely to settle on the membrane surface.
So the question "Can recycling improve the recovery rate?" now has a clear answer: to raise the system recovery rate, the only path is to reduce the discharge from 20 to 15 (or less); the role of recycling is to make this step workable in terms of the final-stage flow velocity—the concentrate flow per element per hour should generally not be lower than 2~3 m³ (see manufacturer datasheets). So the judgment criterion comes down to one sentence: If what is holding you back is the "lower limit of final-stage concentrate flow," recycling helps; if what is holding you back is "scaling," recycling will only make the membrane feed water saltier. The empirical range is to take the recycling flow as 10%~30% of the permeate flow, not exceeding 50% of the concentrate flow and not exceeding 20% of the feed water flow; the recycling point should be connected before the high-pressure pump and after the security filter—do not connect it back to the raw water tank, as that is equivalent to dumping concentrate into the entire pretreatment system.
IX. Energy account: the critical point for saving electricity is about 18 g/L
Whether increasing the recovery rate saves electricity depends on the relative magnitude of two opposing effects. The energy consumption per unit of permeate can be written as pressure divided by recovery rate:
When the recovery rate increases, the denominator becomes larger—this is the electricity-saving side; but pressure P includes an osmotic pressure term, and osmotic pressure is calculated based on the average concentration at the membrane surface. The average concentration = feed concentration × ln[1/(1−R)]/R, which rises faster than R as R increases—this is the electricity-consuming side. Dividing the two sides yields an optimal recovery rate—it follows the feed water salinity:
| Influent TDS | R=70% | R=75% | R=80% | R=85% | R=90% | Most energy-efficient R |
|---|---|---|---|---|---|---|
| 2 g/L (brackish water) | 0.525 | 0.499 | 0.478 | 0.464 | 0.457 | approx. 90% |
| 5 g/L | 0.717 | 0.691 | 0.675 | 0.669 | 0.679 | approx. 85% |
| 10 g/L | 1.037 | 1.012 | 1.002 | 1.011 | 1.049 | approx. 80% |
| 20 g/L | 1.677 | 1.654 | 1.657 | 1.694 | 1.789 | approx. 75% |
| 35 g/L (seawater) | 2.636 | 2.617 | 2.639 | 2.720 | 2.900 | approx. 75% |
Multi-industry nationwide applications (full-membrane desalinated water in the s
Pilot to engineering scale (single unit 61 m³/h to 1500 m³/d; concentrate reduct