Reverse Osmosis: 75% is a 4-fold concentration, not 1.33-fold; at 80%, the concentrate volume is reduced by 20%, but not a single ounce of salt is removed.

Multi-industry nationwide applications (full-membrane desalinated water in the s
Pilot to engineering scale (single unit 61 m³/h to 1500 m³/d; concentrate reduct

Reverse Osmosis: 75% is a concentration factor of 4, not 1.33; with 80%, concentrate volume drops by 20% while salt remains unchanged

The previous article discussed the meter at the discharge outlet and how its error gets amplified exponentially. This article moves one step upstream to discuss the most frequently cited parameter in membrane systems—recovery rate. It looks like just a percentage, but it actually determines four things at once: how concentrated the concentrate is, how much osmotic pressure the membrane surface must withstand, how large the downstream evaporator needs to be, and whether the produced water is still clean. These four things do not point in the same direction, so "increasing the recovery rate" is never simply a good thing or a bad thing—it depends on which one gives out first.

Industrial Water Treatment Technical Notes · 2026-11-21 · Approximately 7 100 words in total, 11 tables, 3 figures, 15 references

The definition of recovery rate is only one line: permeate flow divided by feed flow. The trouble is that "feed flow" has three candidates, "concentrate" has two interpretations, and the "concentration factor" derived from it can yield four different values across four sets of materials—4.00, 3.94, 3.89, and the 3.20 actually given by the bottle of concentrate on site. All four numbers are legitimate. The difference is not in the arithmetic, but in which quantity you hold constant.

1. Recovery rate is not a setpoint; it is the quotient of flows

First, something that is most easily mistaken for a fault on site: the recovery rate changes by itself. It is not a knob that can be turned to 75%; it is permeate flow divided by feed flow. Reverse Osmosis permeate flow varies with water temperature, and the empirical value is that for every 1 ℃ decrease, permeate flow drops by about 3%. From 25 ℃ to 10 ℃, the permeate coefficient falls to 0.633. If the feed flow does not change and the pressure does not change, the original 75% recovery rate will become 47.5% by itself—not because the membrane is damaged, not because the antiscalant has failed, but simply because the water is colder, the viscosity is higher, and the permeation is lower.

Conversely, if 75% must be maintained, then the feed must be reduced from 100 to 63, so that permeate and feed shrink in the same proportion. At this point the recovery rate is preserved, but the permeate flow drops by 37%. These two responses look completely different in the operating log: one says "insufficient recovery rate, suspect Membrane Fouling," and the other says "decreased permeate flow, suspect Membrane Fouling"—but both are actually water temperature.

So when looking at the recovery rate number, the first question to ask is not "how much," but "at what water temperature and what feed flow was it measured?" Clause 7.3.11.5.3 of HJ 579—2010 gives the "raw water recovery rate"—a capability value under the design conditions at rated permeate flow, not a measured ratio at any given moment. The 75% measured during acceptance and the 47% in the winter log can both be true at the same time.

2. 1.33 and 4.00: two interpretations of the same 75%

Substituting 75% into three different formulas yields three numbers that are all "correct":

  • Permeate accounts for 75% of feed, so concentrate accounts for 25% of feed—this is the water volume share;
  • Feed is 1/0.75=1.33 times permeate—this is the water volume ratio, also called the "feed ratio";
  • Concentrate concentration is 1/(1−0.75)=4 times the feed concentration—this is the concentration factor.

All three numbers are born from 75%, but their dimensions are completely different. The consequence of treating 1.33 as the concentration factor is calculable: if concentrate salinity is estimated at 1 330 mg/L, the actual value is 4 000 mg/L, three times lower. If antiscalant is dosed according to this number, the dosage is only one third of what it should be; if silica is checked against this number, the check table says "unsaturated" while precipitation has already begun on the membrane. This type of error does not show up in the calculation sheet, because that column in the calculation sheet is called "concentration factor," and the number filled in looks like a factor.

Table 1 Recovery Rate, Concentrate Share, Feed Multiple and Concentration Factor (Four Facets of the Same Thing)
Recovery RateConcentrate as % of FeedFeed/Permeate (Water Volume Ratio)Concentration Factor 1/(1−R)Corrected for 98% RejectionSalt in Permeate as % of Feed
50%50%2.002.001.972.8%
60%40%1.672.502.453.1%
70%30%1.433.333.253.4%
75%25%1.334.003.893.7%
80%20%1.255.004.844.0%
85%15%1.186.676.414.5%
90%10%1.1110.009.545.1%
95%5%1.0520.0018.806.3%

The last column in the table deserves a separate look: when the feed salt content is 1 000 mg/L, the permeate at a recovery rate of 75% is 37 mg/L, and at 90% it is 51 mg/L.Each step up in recovery rate makes the permeate a little dirtier, because the average concentration at the membrane surface is rising. This column will be used again in Section 9.

Three relationship lines between recovery rate and concentration factor: theoretical formula, corrected by 98% rejection, and the easily misused water volume ratio
Figure 1 Three positions of the same 75% on the three lines: water volume ratio 1.33, theoretical concentration factor 4.00, and corrected by 98% rejection 3.89. Horizontal axis: recovery rate; vertical axis: factor.

III. Three Recovery Rates: System, Stage, and Element — Chained Together by Multiplication

For a two-stage Reverse Osmosis / RO system, there are three "recovery rates" on paper, and their denominators are not the same water:

  • System recovery rate = permeate/fresh feed water; this is the number reported externally;
  • Stage recovery rate = permeate of this stage/feed water of this stage; the feed water of the second stage is the concentrate of the first stage;
  • Element recovery rate = permeate of a single membrane element/feed water of a single membrane element, usually only 10%~15%.

For stages in series, the system recovery rate is calculated by multiplication, not addition: system recovery rate = 1−(1−R₁)(1−R₂). For example, with a first stage of 60% and a second stage of 37.5%, the system is 75.0%; adding the two numbers gives 97.5%, which is a number that does not exist. Conversely, from 60% to 75%, the second stage only needs 37.5%—this is the essence of a tapered array: the final stage produces less permeate and passes more water, trading permeate rate for membrane surface velocity.

Table 2 Definitions, Typical Values, and Common Mistakes of the Three Recovery Rates
NameWhat Water Is the DenominatorTypical ValueCommon Mistake
System Recovery RateFresh feed water (excluding recirculation)Brackish water 75%~80%, seawater desalination 35%~45%With concentrate recirculation, mistakenly using "flow before membrane" as the denominator, resulting in an underestimated value
Stage Recovery RateFeed water of this stage (concentrate from the previous stage)First stage 55%~65%, last stage 30%~40%Adding the two stage values together, writing 60%+37.5% as 97.5%
Element Recovery RateFeed water of a single element10%~15%Taking the single-element 15% as the system value, underestimating the membrane area by five times when back-calculating
Module (Pre-membrane) Recovery RateFlow before membrane = feed + recirculation5~15 percentage points lower than the system valueMixed up with system recovery rate, the two values "don't match" each other

Here is a fact that can be seen by arithmetic alone: the system recovery rate of a two-stage series system is always less than the sum of the two stages, and as the number of stages increases, the system recovery rate approaches 1 more and more slowly. Three stages at 85%~90% is already a stretch, and beyond four stages the marginal gain is almost zero—because the feed water to the last stage is only a few percent, and no matter how much you squeeze, you can't squeeze out more water. The standard design guidelines state the correspondence between the number of stages and recovery rate very plainly: single stage <50%, two stages <75%~80%, three stages <85%~90%.[1]

IV. The concentration factor has four values, and each difference has its own destination

1/(1−R) is the concentrate concentration when "no salt passes through the membrane at all." A real membrane is not like this; a salt rejection rate of 98% means that 2% of the salt travels along with the water. Taking this 2% into account, the concentrate concentration should be somewhat lower—but "how much lower" depends on whether you write the permeate concentration as 2% of the feed concentration or as 2% of the membrane-surface average concentration:

Table 3 Same 75%, same 98% rejection rate, three algorithms give three concentrate concentrations (feed 1 000 mg/L)
AlgorithmMeaning of the formulaConcentrate concentrationConcentration factorDifference from theoretical value
Pure theoreticalAll salt remains on the concentrate side4 000 mg/L4.00—
Salt passage calculated from feed concentrationPermeate = 2% × feed3 940 mg/L3.941.5%
Salt passage calculated from membrane-surface average concentrationPermeate = 2% × average feed (1.848 times)3 889 mg/L3.892.8%
Measured (Total Dissolved Solids)Sampling and measurementDepends on siteDepends on site—

The difference among the first three numbers is only 1–3 percentage points, which is negligible in engineering terms. What is truly informative is the fourth one: calculating the concentration factor separately for different ions in the same bottle of concentrate. The following set of numbers is an example (feed calcium 62.5, chloride 120, silica 20 mg/L, recovery rate 75%, theoretical corrected value 3.89):

Table 4 In the same bottle of concentrate, three ions give three concentration factors (example values, for algorithm demonstration)
ItemInfluent mg/LMeasured Concentrate mg/LApparent Concentration FactorLower than 3.89 byWhere the difference went
Chloride1204303.587.9%Does not precipitate; can only be attributed to sampling, analysis, or conversion errors
Calcium62.52003.2017.7%43 mg/L calcium, equivalent to about 107 mg/L as calcium carbonate, deposited on the membrane
Silica (dissolved)20773.851.0%Not yet polymerized, still in solution
This is a criterion that can be used without dismantling the membrane. Take a bottle of concentrate and divide the chloride, sodium, calcium, sulfate, and silica values by their respective influent values: ions that should not precipitate (chloride, sodium) reading low → a measurement problem; ions that do precipitate (calcium, barium, sulfate, silica) reading low → something is on the membrane. Only when the deviation directions of the two ion categories differ in the same sample on the same instrument can "analytical error" and "scaling" be separated. If both read low by the same ratio, the sampling point is most likely wrong—for example, the concentrate sample was taken from the first-stage outlet rather than the terminal outlet.

This criterion has another prerequisite that is easily overlooked: do not use conductivity to calculate the concentration factor. Conductivity and salt content do not have a linear relationship in the high-concentration range (the deviation is obvious above 4 000 mg/L), and it also drifts with temperature and pH; the same bottle of water can differ by several percentage points at a different temperature. The 3.2 or 4.5 calculated from it cannot be attributed. To calculate conservation, use conservative ions.

V. The upper limit is not set by the membrane, but by four salts

The membrane itself is not afraid of concentrated water; what it fears is that certain substances in the concentrated water will saturate first. Each of the four sparingly soluble salts has a boundary of "precipitation once concentrated further." Back-calculating the boundary into recovery rate and taking the smallest one is the recovery rate this system can truly achieve:

Table 5 Limit recovery rate of each of the four sparingly soluble salts (example water: influent TDS 1 000, calcium 62.5, alkalinity 50, sulfate 100, silica 20 mg/L, 25 ℃)
ConstraintCriterionBack-calculation methodAllowable recovery rateWhich binds first
Calcium carbonate (LSI)Concentrate LSI ≤1.8 (effective upper limit of antiscalant)Calculate pHs step by step, bisection back-calculation95.1%At 75%, LSI is only +0.45, the loosest
Calcium sulfateIon product ≤0.8KspR=[1−1/√(0.8Ksp/IP)]×10091.0%Relatively loose
SilicaConcentrate ≤106 mg/L (25 ℃)R=1−influent silica/saturated silica81.1%This is what binds first in summer
Barium/strontium sulfateIon product ≤0.8Ksp (Ksp on the order of 10⁻¹⁰)Same as aboveOften negativeCan only rely on antiscalant, not on lowering recovery rate
Winter (10 ℃) recalculationSilica ≤40 mg/LSame as above50.3%The real ceiling in winter

Take the minimum: 81% in summer and 50% in winter. This is why the opening of this article says "the design value of recovery rate is not the industry convention of 75%" — it is obtained by back-calculating each of the four salts once and taking the minimum, then correcting once by the coldest-month temperature, and finally leaving a margin of 10~15 points. The industry's "brackish water 75%" is merely the result of these four calculations coincidentally falling into the same range for a typical water quality, not the cause.

The LSI in Table 5 is calculated using the classic four-term formula: pHs=(9.3+A+B)−(C+D), A=(lg TDS−1)/10, B=−13.12 lg(t+273)+34.55, C=lg(calcium hardness)−0.4, D=lg(alkalinity) (both calcium and alkalinity are calculated as calcium carbonate, mg/L). For the example water at recovery rates of 60%, 75%, 85%, and 95%, the calculated LSI values are +0.06, +0.45, +0.87, and +1.78, respectively.

VI. Silica: The Same 20 mg/L, 25 ℃ Allows 81%, While 10 ℃ Allows Only 50%

Among the four salts, silica dioxide is the most unreasonable, because its solubility varies too steeply with temperature. The empirical formula given in engineering manuals is saturated concentration=4.39t−3.66 (t is the concentrated water temperature in ℃), while another operation summary gives "25 ℃ not exceeding 100 mg/L, 5 ℃ not exceeding 25 mg/L". The two sources are almost consistent at 25 ℃ (106 and 100), but differ by a margin at 5 ℃ (18.3 and 25). Taking the conservative one does not affect the conclusion: when the temperature drops from 25 to 5, the saturated concentration of silica falls to one-fifth to one-sixth.

Table 6 Supersaturation factor of concentrate at influent silica 20 mg/L and 75% recovery operation
Water Temperature ℃Concentrate SiO₂ mg/L
(based on CF 4)
Saturation Concentration mg/LSupersaturation FactorAllowable Recovery at This Temperature
2580.0106.10.75 (unsaturated)81.1%
2080.084.10.9576.2%
1580.062.21.2967.8%
1080.040.21.9950.3%
580.018.34.37Not feasible (negative value)
Variation of allowable recovery with water temperature at influent silica 20, 25, 30 mg/L, and intersections with the 75% design line
Figure 2 The limit recovery allowed by silica decreases as water temperature drops (the three lines correspond to feed silica 20 / 25 / 30 mg/L), and the intersection with the 75% design line is "the month when silica scaling begins."

This table explains a phenomenon that repeats every winter: a system that runs perfectly well in summer, once the feed 11 月, begins to show rising differential pressure, declining water production, and chemical cleaning that cannot restore the original value; on inspection, the last-stage membrane surface has a glassy layer.This is not an operational error; it is the inevitable result of designing for summer conditions.If the feed silica is 20 mg/L and the water temperature is 10 ℃, there are only two ways to achieve 75%: remove the silica first (softening plus silica removal, or magnesium salt co-precipitation), or reduce the recovery to 50%. A third option is heating—heating the 10 ℃ water to 25 ℃ requires 62.8 MJ per cubic meter, which at 90% thermal efficiency translates to 19.4 kWh; this cost is basically untenable in the face of electricity prices.

7. Calcium Sulfate: What Softening Buys Back Is 10 Points, Not "Better Water Quality"

The calcium sulfate boundary can be written as a single invertible equation; the form in design manuals is:

Rmax = [ 1 − 1 / √( 0.8 Ksp / (Ca²⁺·SO₄²⁻) ) ] × 100%

where 0.8 is the safety factor, Ksp is taken as the apparent solubility product at the ionic strength of the concentrate (not the value in pure water), and Ca and SO₄ are taken as the molar concentrations in the feed. Substituting into the manual's worked example (calcium 2.5 mmol/L, sulfate 3.13 mmol/L, Ksp taken as 2.5×10⁻⁴, 25 ℃) gives 80.2%.[2] This number does not contradict the 91.0% calculated in Table 5 of this article using a different water quality—different ion products give different boundaries, and the same formula applied to different water qualities will naturally give different numbers.

Table 7 With the same calcium sulfate boundary, how much recovery can be bought back by removing half of the calcium or sulfate
ConditionIon Product (mol/L)²0.8Ksp/Ion ProductLimit RecoveryRelative to Raw Water
Raw Water7.83×10⁻⁶25.680.2%—
Calcium Halved (Sodium Exchange or Lime Softening)3.91×10⁻⁶51.186.0%+5.8 points
Calcium and Sulfate Each Halved1.96×10⁻⁶102.290.1%+9.9 points
Each Reduced to One Quarter4.89×10⁻⁷409.095.1%+14.9 points

Note the nature of the numbers in this column: they are the critical values at which "a little more concentration causes precipitation," not values at which "long-term stable operation is possible." In engineering, 10~15 points must still be reserved below them. So the real significance of softening is not "better water quality," but raising the upper limit of recovery for this system from 80 to 90, at the cost of the acid, alkali, and salt used for regeneration, plus a new stream of regeneration waste liquid. This account must be calculated together: whether the water saved by the extra 10 points of recovery can offset the chemicals and waste liquid disposal of the softening system. Most Reclaimed Water Reuse projects can make it balance, while most high-salinity wastewater projects cannot—because the water saved in the latter is not valuable in the first place, and the waste liquid is more expensive.

VIII. Concentrate Recycle: System Recovery Unchanged, Element Recovery Drops by 13 Points

Concentrate recycle is treated in the field as a "master key to improving recovery," but this claim is only half true. Let the fresh feed be 100, the permeate be 80, and the discharged concentrate be 20. Recycle 20 of the concentrate to the front of the high-pressure pump, so the flow before the membrane becomes 120. At this point the two "recoveries" are:

  • System recovery = 80/100 = 80.0% — the denominator is the fresh feed, and recycle does not change it;
  • Element recovery = 80/120 = 66.7% — the denominator is the flow before the membrane, which recycle has enlarged to 20%.

One and the same action: one number stays unchanged while the other drops by 13.3 points. This clarifies the nature of the statement "recycle improves recovery": turning on recycle alone without changing the discharge leaves recovery completely unchanged, and power consumption will even rise — the extra 20 m³/h of water is pressurized one more time. What it buys is something else: flow velocity; the cost is written in the other two columns — the salinity of the feed before the membrane rises from 1.00 to 1.64 (concentrate at four times the concentration of 20 m³/h is mixed into the feed of 100 m³/h), and the element concentration factor drops from 4.84 to 2.95.

Table 8 The accounting of concentrate recirculation (example: fresh feed 100, permeate 80, discharge 20, recirculation 20 m³/h)
ItemNo RecirculationRecirculation 20Change
Fresh feed m³/h100100Unchanged
Flow before membrane m³/h100120+20%
Permeate m³/h8080Unchanged
Discharged concentrate m³/h2020Unchanged
System recovery80.0%80.0%Unchanged
Element recovery80.0%66.7%−13.3 points
Salt content of membrane feed (index)1.001.64+64%
Element concentration factor (concentrate/membrane feed)4.842.95−39%
Membrane surface velocity in the last stageLowHighFouling slows down

The last two rows must be read together: the element concentration factor drops by 39%, but the concentration of the concentrate itself does not change at all (still 4.84 times); only the denominator is lowered—the salt content of the membrane feed is raised. Therefore, the statement "recirculation reduces the scaling risk" is likewise inaccurate: the scaling driving force at the tail end is unchanged, while the average concentration in the middle stages is actually higher. The real benefit lies in the flow velocity: as the membrane surface velocity increases, the concentration polarization coefficient decreases, and colloids and particles are less likely to settle on the membrane surface.

So the question "Can recycling improve the recovery rate?" now has a clear answer: to raise the system recovery rate, the only path is to reduce the discharge from 20 to 15 (or less); the role of recycling is to make this step workable in terms of the final-stage flow velocity—the concentrate flow per element per hour should generally not be lower than 2~3 m³ (see manufacturer datasheets). So the judgment criterion comes down to one sentence: If what is holding you back is the "lower limit of final-stage concentrate flow," recycling helps; if what is holding you back is "scaling," recycling will only make the membrane feed water saltier. The empirical range is to take the recycling flow as 10%~30% of the permeate flow, not exceeding 50% of the concentrate flow and not exceeding 20% of the feed water flow; the recycling point should be connected before the high-pressure pump and after the security filter—do not connect it back to the raw water tank, as that is equivalent to dumping concentrate into the entire pretreatment system.

IX. Energy account: the critical point for saving electricity is about 18 g/L

Whether increasing the recovery rate saves electricity depends on the relative magnitude of two opposing effects. The energy consumption per unit of permeate can be written as pressure divided by recovery rate:

E = P / (R·η) × 0.0278 (kWh/m³, P in bar)

When the recovery rate increases, the denominator becomes larger—this is the electricity-saving side; but pressure P includes an osmotic pressure term, and osmotic pressure is calculated based on the average concentration at the membrane surface. The average concentration = feed concentration × ln[1/(1−R)]/R, which rises faster than R as R increases—this is the electricity-consuming side. Dividing the two sides yields an optimal recovery rate—it follows the feed water salinity:

Table 9 Specific energy consumption per unit of produced water under different influent salinity (NDP baseline 8 bar, pump efficiency 0.8, osmotic pressure coefficient 0.75 bar per g/L)
Influent TDSR=70%R=75%R=80%R=85%R=90%Most energy-efficient R
2 g/L (brackish water)0.5250.4990.4780.4640.457approx. 90%
5 g/L0.7170.6910.6750.6690.679approx. 85%
10 g/L1.0371.0121.0021.0111.049approx. 80%
20 g/L1.6771.6541.6571.6941.789approx. 75%
35 g/L (seawater)2.6362.6172.6392.7202.900approx. 75%
Specific energy consumption per unit of produced water versus recovery rate; four curves correspond to influent salinity of 2, 5, 10, and 20 g/L, each with its own minimum point
Figure 3 Each curve has a minimum point, and the minimum point shifts left as the feed water salinity increases. At low salinity, raising to 90% still saves power; at high salinity, after 75% every further step consumes more power.

Specifically for the most commonly used step: from 75% to 80%, at feed water 2 g/L the power consumption drops from 0.499 to 0.478 (saving 4.2%), and at feed water 20 g/L it rises from 1.654 to 1.657 (an increase of 0.2%). Solving for the intersection of these two curves gives a critical feed water salinity of approximately 17.7 g/L (under NDP 8 bar, coefficient 0.75; the general formula is 1.67P₀/k). Below it, raising recovery saves power; above it, raising recovery relies on chemicals and softening, saving no power at all.

This also explains why "raising recovery" is pure gain on brackish water projects, while on high-salinity wastewater projects a full life-cycle assessment must be done first: the water cost saved, the power saved, the additional scale inhibitor dosed, the shortened membrane life, and the additional load on the downstream evaporator due to higher feed concentration—all five items must go into the table together.

X. Permeate Account: Recovering 15 more points, permeate salinity rises by 38%

The last column of Table 1 already reveals it: as recovery rises from 75% to 90%, permeate salinity increases from 3.7% of the feed water to 5.1%. This ratio is independent of salt rejection and depends only on the average membrane surface concentration—the salt passage rate remains unchanged, so however much the membrane surface concentration rises, the permeate concentration rises by the same amount:

Table 10 Effect of recovery on both concentrate and permeate at feed 1 000 mg/L and salt rejection 98%
RecoveryConcentrate mg/LAverage Membrane Surface Concentration mg/LPermeate mg/LChange Relative to 75%
75%3 8891 84837.0—
80%4 8392 01240.2+8.6%
85%6 4142 23244.6+20.5%
90%9 5392 55851.2+38.4%

37 to 51 mg/L is no big deal for boiler make-up water, but it is a different story downstream of this chain: if secondary RO or EDI follows, a 38% rise in feed salinity means a 38% load increase on the secondary stage, the EDI current must be adjusted accordingly, and a chunk of the permeate resistivity margin is consumed. Conversely, if this is a system where "primary RO permeate is directly reused as circulating water make-up," there is no difference between 51 mg/L and 37 mg/L, and those 15 points should be raised.

By the way, here is an often overlooked corollary: at 75% recovery, the colloid concentration in the last-stage membrane elements is four times that of the first stage.[3] Therefore, colloidal fouling always starts in the last stage, and the last stage happens to be the segment with the lowest flow velocity. The three measures of tapered array, interstage boosting, and concentrate recirculation are all essentially supplementing the flow velocity of the last stage.

XI. The standard only specifies lower limits: 30 / 50 / 70 and 90.25%

Article 7.3.11.5.3 of HJ 579—2010 specifies three tiers of lower limits for raw water recovery based on water production capacity: equipment with water production capacity ≤100 m³/d ≥30%; 100~1 000 m³/d ≥50%; ≥1 000 m³/d ≥70%. Clause 7.3.11.5.4 of the same article requires that the rated desalination rate be no less than 95%, and that after one year of continuous operation it be no less than 95% of the rated value.[4]

Table 11 HJ 579—2010: Three Sets of Figures for Reverse Osmosis Equipment
ClauseIndicatorValueHow to Read It
7.3.11.5.3 aRaw water recovery rate (permeate flow ≤100 m³/d)≥30%This is a capability floor, not a performance guarantee. Compliance is achieved at 70%, but 70% water may not even reach silica saturation in winter—compliance and long-term operability are two different things
7.3.11.5.3 bRaw water recovery rate (100~1 000 m³/d)≥50%
7.3.11.5.3 cRaw water recovery rate (≥1 000 m³/d)≥70%
7.3.11.5.4Salt rejection rateRated ≥95%; after one year ≥rated value × 95% = 90.25%The only indicator in the entire document that "degrades over time," writing membrane lifespan into acceptance
7.3.11.5.6Feed water fouling index SDI≤4Correlated with recovery rate: the higher the SDI, the lower the recovery rate that can be sustained
7.3.11.5.6Free residual chlorine (polyamide composite membrane)<0.1 mg/LOxidative damage is irreversible; unrelated to recovery rate but equally fatal

Note the origin of the figure 90.25%: 95% multiplied by 95%. It is not an independent rule that "90.25% is allowed after one year," but the arithmetic result of the phrase "not less than 95% of the rated value." The same sentence has two readings at the acceptance meeting—one says "rated 95, 90.25 after one year qualifies," the other says "rated 97, only 92.15 after one year qualifies." Different readings mean the acceptance threshold differs by 1.9 points, and both figures can find a basis in the contract, depending on what the rated value is written as.

XII. Two Projects: One Sends the Concentrate Away, One Takes the Concentrate Apart

(I) Full-Membrane Process at a Steel Plant: Concentrate Goes to the Turbid Circulating Water System

Demineralized water stations at steel enterprises generally use Ultrafiltration plus two-stage Reverse Osmosis. The recovery rate of the first-stage Reverse Osmosis is stable at around 75%, the concentration factor of the concentrate is calculated as 4, and the salt content is about 4 times that of industrial fresh water; although the Ultrafiltration recovery rate can reach 90%, it does not desalinate, and its concentration factor is calculated as 1.[5] This means that of the Ultrafiltration permeate going in, 100 m³/h, 75 m³/h becomes demineralized water and 25 m³/h becomes concentrate—a quarter of the water turns into water at four times the concentration, and its destination is the turbid circulating water system as make-up water.

This approach gains in terms of water volume: the Suspended Solids in the concentrate are similar to those in the Ultrafiltration effluent, and although the salt content is high, the turbid circulating system itself is concentrating, so it can absorb it. It should be noted that this shifts the problem elsewhere: the salt in the concentrate does not disappear; it is merely booked on the account of the circulating water system. The upper limit of the concentration factor on the circulating water side (the sum line of calcium hardness plus total alkalinity) will be lowered by this make-up water, the achievable concentration factor becomes smaller, and the blowdown volume increases. The water balance of the whole plant must be calculated together; otherwise, the water saved at the demineralized water station will be discharged at the circulating water station.

(II) Zero Liquid Discharge of Display Wastewater: Taking 25% Apart into 90% Water and 10% Salt

A reclaimed water reuse unit of a display enterprise is equipped with 3 sets of Reverse Osmosis with a capacity of 50%, each with a treatment capacity of 61 m³/h, a recovery rate of 75%, a permeate flow of 46 m³/h, and a concentrate flow of 15 m³/h; the design Membrane Flux is 17.1 LMH, the salt rejection rate is ≥95%, and fouling-resistant polyamide composite membranes (BW30FR-400/34i) are selected, with a two-stage design, 4-element membrane housings, and an arrangement of 11:7.[6]

Putting these numbers together allows a mutual verification: 61×0.75=45.75, which matches the permeate flow of 46; 46×1 000÷17.1=2 690 m² of membrane area; 11:7 means 18 membrane housings, 4 elements per housing, 72 elements in total, and 2 690÷72=37.4 m²/element, which is exactly the standard element area of 400 ft² (37.16 m²)—three independently given numbers (permeate flow, flux, arrangement) close on the same membrane element, indicating that this set of parameters was not copied. Looking downstream: the combined concentrate of 3 sets is 45.75 m³/h, and the design scale of the concentrated brine treatment unit is 45 m³/h, which also matches.

The concentrated brine unit is a complete concentration chain: the concentrate is first mixed with the Phase I concentrate and enters a weak-acid cation bed to reduce polyvalent cations to a hardness of <1 mg/L (filtration rate 25 m/h, resin bed 1.6 m, hydrogen-form operation, hydrochloric acid regeneration, cycle 3~4 天), then enters a decarbonation tower to reduce carbon dioxide to <5 mg/L (packing layer 2.5 m), and then enters the concentrate Reverse Osmosis, DTRO, MVR, and dryer. The division of labor between high-pressure Reverse Osmosis and disc-tube Reverse Osmosis is clear: the former raises the concentrate TDS from a few g/L to 50~100 g/L, and the latter uses 75~120 bar to push it above 150 g/L, so the water entering the evaporator is therefore less than 5% of the original wastewater.[7]

Every step in this chain does the same thing—pushing the concentration factor one stage downstream. With each stage, the water volume is reduced by half to eighty percent, the concentration doubles, and the unit treatment cost rises by one level. So-called Zero Liquid Discharge is not "no discharge"; it is taking 25% of concentrate apart into "90% of water for reuse + 10% of salt for offsite transport," and the entire cost is loaded onto that last small segment.

XIII. Five Common Misuses

Table 12 Five high-frequency misuses related to recovery rate and their consequences
MisuseWhat is wrongConsequenceCorrect practice
Treating 1/R as the concentration factor1.33 is a water volume ratio, not a concentration ratioThe concentrate is calculated as 3 times with low salinity, resulting in insufficient scale inhibitor dosing and distorted silica verificationUse 1/(1−R), then correct by rejection rate
Treating "osmotic pressure 30 bar" as the osmotic pressureThe osmotic pressure of 20 g/L is only 15~17 bar; 30 bar is the operating pressure, which also includes NDPOverestimating 80% when back-calculating membrane area and pump headCalculate osmotic pressure at 0.71~0.85 bar per g/L, and list NDP separately
Calculating the concentration factor from conductivityNonlinear at high concentration, drifting with temperature and pHThe same water sample yields 3.2 or 4.5, making attribution impossibleUse conservative ions such as chloride and sodium
Adding the recovery rates of two stagesSeries connection is multiplicative: 1−(1−R₁)(1−R₂)60%+37.5% reported as 97.5%, overestimating the system by 22.5 pointsCalculate multiplicatively, or directly use the system flow ratio
Treating recovery rate as a fixed setpointIt is a flow ratio and varies with water temperatureIn winter, 75% changes to 47.5%, misjudged as membrane foulingWhen recording recovery rate, always record water temperature and influent flow rate at the same time

XIV. Closing in One Sentence

Recovery rate is not membrane efficiency; it is the distribution of membrane output. Its numerator is permeate and its denominator is feed, while what truly determines how high it can go are the things not in the formula: the respective boundaries of four sparingly soluble salts, a silica solubility that varies fivefold with the seasons, and the feed concentration of the downstream evaporator. Calculate each of these once, take the minimum, then leave a margin—this is where 75% or 65% or 85% comes from. The reason an industry convention is a convention is simply that it happens to be right for one class of typical water quality.

Where to go in the next article is not yet decided, but the method is the same: whenever you encounter a percentage, first ask what water its numerator and denominator each refer to; whenever you encounter a "multiple", first ask what quantity it holds constant.

References

  1. LANXESS. Design Guidelines for the Design of Reverse Osmosis Membrane Systems. §1.5.4 Table 1.4 (correspondence between recovery rate and concentration factor: 50%→2, 75%→4, 80%→5, 90%→10); §1.5.5 (single-stage <50%, two-stage <75%~80%, three-stage <85%~90%).
  2. Membrane Development Specialists (MDS). Technical Manual. Calcium sulfate limiting recovery formula Rmax=[1−1/√(0.8Ksp/(Ca·SO₄))]×100 and worked example (calcium 2.5×10⁻³, sulfate 3.13×10⁻³ mol/L, Ksp 2.5×10⁻⁴, 25 ℃, yielding 80.2%); silica saturation concentration formula SiO₂max=correction factor×(4.39t−3.66).
  3. "Discussion of Several Issues in the Operation and Management of Reverse Osmosis Units", Wastewater Treatment Engineering Network, 2010-01-22: concentrate silica 25 ℃ should not exceed 100 mg/L, 5 ℃ should not exceed 25 mg/L; when concentrate LSI<0 and calcium sulfate ion product<10×10⁻⁵, scaling will not occur; at recovery 75%, the colloidal concentration at the terminal membrane element is approximately four times that of the first stage; SDI should be<4.
  4. HJ 579—2010 "Technical Specification for Membrane Separation Process Wastewater Treatment Engineering" Article 7.3.11.5.3 (raw water recovery 30%/50%/70% three levels), Article 7.3.11.5.4 (desalination rate ≥95%, not lower than the rated value 95% after one year), Article 7.3.11.5.6 (SDI≤4, free residual chlorine<0.1 mg/L).
  5. "Disposal and Application of Reverse Osmosis Concentrate in Steel Enterprises", Wastewater Treatment Engineering Network, 2009-11-17: primary Reverse Osmosis recovery approximately 75%, concentration factor CF=1/(1−75%)=4, concentrate salinity is 4 times that of industrial fresh water, 25% Ultrafiltration permeate converted to concentrate; Ultrafiltration recovery 90% but concentration factor calculated as 1; primary concentrate reused for turbid circulating water make-up, secondary concentrate returned to the Ultrafiltration permeate tank.
  6. "Zero Liquid Discharge Process for Luminescent Display Wastewater", Wastewater Treatment Engineering Network, 2022-08-01: Reclaimed Water Reverse Osmosis 3×50%, single unit 61 m³/h, recovery 75%, permeate 46 m³/h, concentrate 15 m³/h, design flux 17.1 LMH, desalination rate ≥95%, BW30FR-400/34i, two-stage 4-core membrane housing 11∶7; concentrated brine unit 45 m³/h, including weak acid cation bed (effluent hardness<1 mg/L, filtration rate 25 m/h, resin layer 1.6 m, cycle 3~4 天), decarbonation tower (CO₂<5 mg/L, packing 2.5 m), concentrate Reverse Osmosis, DTRO, MVR, dryer.
  7. "High-Pressure Reverse Osmosis System Recovery Won't Go Up? Calculate the 6 Key Parameters Clearly Before Design", Changhai Environmental Protection: HPRO influent TDS 5 g/L, at recovery 75% the concentrate is approximately 20 g/L; DTRO pressure 75~120 bar, concentrate TDS can reach above 150 g/L, concentrate reduction 90%, evaporation volume less than 5% of the original wastewater; influent SDI should be<4, residual chlorine<0.1 mg/L, water temperature 15~30 ℃.
  8. "Brief Discussion on the Limiting Recovery of RO Units (Part 2)", Muma River Water Treatment: the maximum saturation concentration of sparingly soluble salts occurs at the terminal membrane surface rather than in the terminal concentrate, and must be multiplied by the concentration polarization factor (primary RO≤1.2, secondary≤1.4); the limiting recovery is calculated separately for the three pathways of sulfate, silicate, and calcium carbonate, and the minimum value is taken.
  9. "RO Concentrate Recovery System Process", Zhihui Industry: the effective range of scale inhibitor is LSI 0~1.8, beyond 1.8 adjustment is required first; at pH 7 the solubility of silica in concentrate is approximately 100~120 mg/L; with influent silica 50 mg/L, the concentrate can only be concentrated 2 times (recovery 50%), and with influent silica 20 mg/L, it can be concentrated 5 times (recovery 80%).
  10. "Reverse Osmosis Plan Chemical Dosing Management", Juxinglong Water Treatment: pHs four-term formula A=(lg TDS−1)/10, B=−13.12lg(t+273)+34.55, C=lg(calcium hardness)−0.4, D=lg(alkalinity), and LSI worked example; sulfate scaling controlled by ion product<0.8Ksp.
  11. "Study on Recovery and Concentrate Discharge Optimization of Reverse Osmosis Systems", Jingmei Filtration: single-stage single-pass 60%~70%, single-stage two-pass 75%~80%, with softening and scale inhibition up to 85%~90%; recovery 75%/80%/85%/90% corresponds to concentration factor 4/5/6.67/10.
  12. "Recovery–Concentrate Volume Conventions in Zero Liquid Discharge (ZLD) Schemes: 6 Common Pitfalls in a 1500 t/d Case", Shuyuan: recovery 75% corresponds to concentration factor 4, concentrate volume 375 t/d; at rejection rate 98%, concentrate TDS 19 700 mg/L (apparent concentration factor 3.94), differing from the purely theoretical 20 000 mg/L by 1.5%.
  13. "The Correct Way to Open Reverse Osmosis Concentrate Reflux": reflux volume is generally 10%~30% of permeate volume, not exceeding 50% of concentrate flow, and not exceeding 20% of influent flow; the reflux point should be before the high-pressure pump and after the security filter; reflux increases membrane surface velocity and reduces concentration polarization, but raises influent salinity.
  14. Activated Carbon filter parameters from the same article "Zero Liquid Discharge Process for Luminescent Display Wastewater": 3 units, 2 in service and 1 standby, single unit 63 m³/h, filtration rate 10 m/h, carbon layer 2 m, quartz sand support layer 0.2 m, backwash intensity 7 L/(s·m²), backwash water uses Reverse Osmosis permeate—used to illustrate the constraints of pretreatment on recovery.
  15. Self-calculated portions of this article (marked "self-calculated"): the rejection correction column of Table 1, the membrane surface average concentration algorithm of Table 3, the ion apparent concentration factor example of Table 4, the LSI stepwise back-calculation of Table 5, the supersaturation factor of Table 6, the energy consumption curve and 17.7 g/L critical value of Table 9. The NDP baseline (8 bar), pump efficiency (0.8), and osmotic pressure coefficient (0.75 bar per g/L) in the formulas are fixed values; changing them will change the specific numbers but not the curve shapes or the direction of the conclusions.
The data in this article are all taken from public standards, design manuals, and public engineering reports; those marked "self-calculated" are obtained by substituting into the formulas in the text; the example water quality is only used to demonstrate the algorithm and does not represent the design parameters of any specific project. For the specific values of recovery and membrane area, please refer to the membrane manufacturer's design software and the full water quality analysis of the project.