The national standard "Regulations for the Compilation of Unconventional Water Development and Utilization Plans" (GB/T 47418—2026) was officially implemented on 2026 年 11 月 1 日. This is China's first national standard specifically governing the compilation of unconventional water development and utilization plans. It proposes for the first time a full-process pathway of "preliminary preparation—plan compilation—plan demonstration—plan deliverables", unifies the five categories of terminology—reclaimed water, mine (well) water, seawater and desalinated seawater, harvested rainwater, and brackish water—and promotes the shift of unconventional water from a "supplementary water source" to a "strategic second water source".
A national standard that governs not engineering, but "how to do the accounting"
In the past, when local governments compiled unconventional water plans, the biggest trouble was not technology but definitions. Some places counted only reclaimed water as "unconventional water," while others also included desalinated seawater; for "harvested rainwater," some counted only rainwater collection in building compounds, while others also included pond storage. Once definitions become inconsistent, calculated demand figures no longer match, consensus on allocation schemes becomes difficult, and disputes arise constantly during review.
GB/T 47418—2026 is precisely meant to solve this problem. The standard was proposed and administered by the Ministry of Water Resources, compiled under the auspices of the National Office of Water Conservation, and drafted by the General Institute of Water Resources and Hydropower Planning and Design, Ministry of Water Resources. It was issued on 2026 年 4 月 30 日 and implemented on 11 月 1 日, with 24 pages of main text and approximately 3.3 万 words. It is not an engineering design manual, but a set of general methods for "how to compile a plan, how to do the accounting, and how to demonstrate a scheme."
Five terms: unify the language first
The foundational work at the beginning of the standard is to clearly define five core terms:
- Reclaimed Water—reuse water after sewage treatment, with stable quantity and concentrated sources, suitable for municipal miscellaneous use, landscape water supplementation, and industrial cooling.
- Mine (Well) Water—water generated from mine drainage and mineral extraction processes, with large differences in water quality, mostly used for industry and greening in mining areas and surrounding areas.
- Seawater and Desalinated Seawater—water sources in coastal areas; desalinated water can be used for municipal and industrial water supply.
- Harvested Rainwater—rainwater collected and stored on site, suitable for green space irrigation and supplementary water sources.
- Brackish Water—including slightly brackish water, which can be used for agriculture and industry after treatment.
Although terminology unification appears basic, it actually determines whether all subsequent data can be compared horizontally and aggregated vertically. Without a common language, cross-departmental and cross-level plans cannot be aligned.
Four-step pathway: putting "compiling by experience" into a reusable process
The standard proposes for the first time a full-process technical pathway, with clear outputs at each of the four stages:
- Preliminary Preparation—address "why compile, to which level, and where the boundaries lie," and identify water shortage conditions, the existing water source structure, and the current status of unconventional water utilization.
- Plan Compilation—the core is two accounts: demand analysis and supply analysis, followed by allocation balancing according to different utilization sectors.
- Plan Demonstration—organize experts and relevant departments to evaluate the feasibility, economy, and safety of the scheme.
- Plan Deliverables—output plan texts, charts, and implementation schemes as the basis for subsequent project approval and construction.
This sequence is not arranged arbitrarily. If demand is not calculated accurately, the allocation scheme is empty; if the scheme is not demonstrated, the deliverables cannot be implemented. The value of the standard lies in turning a compilation process that previously relied on personal experience into a reusable and reviewable process.
Two accounts: the demand side looks at "who can accept it," the supply side looks at "where to allocate it"
What needs to be calculated on the demand side is the new water demand in water-scarce areas and which sectors can accept unconventional water; what needs to be calculated on the supply side is how different types of water sources should be allocated across different utilization sectors. The key lies in the eight characters "different types, different sectors"—reclaimed water is suitable for municipal miscellaneous use and industrial cooling, desalinated seawater is suitable for coastal industry, mine water is suitable for areas around mining sites, and harvested rainwater is suitable for green spaces and supplementary water sources. If allocated to the wrong place, the water cannot be used.
The most common deviation in compilation is to treat unconventional water as an isolated chapter and add a paragraph at the end of the text. The main thread of the standard is unified allocation: from the water demand forecasting stage, unconventional water should be included in the balance as one of the available water sources, and the allocation scheme should then be refined later. If the preceding demand forecast is conducted entirely on the basis of conventional water sources and only a paragraph on "reclaimed water utilization" is added at the end, then the plan has not truly aligned with the standard.
Why industrial parks are the biggest beneficiaries
The standard applies to a broad range of subjects: administrative regions at or above the county level, river basins, and specific functional zones such as high-tech zones, economic development zones, and industrial parks. In other words, not only provinces, cities, and counties must prepare plans — an industrial park can also prepare its own plan separately under this standard.
Industrial parks are precisely where unconventional water is easiest to utilize: water use is concentrated, and water quality requirements are clearly tiered — cooling, washing, landscaping, and toilet flushing each have different water quality requirements, making it entirely feasible to replace part of the high-quality water supply with reclaimed water or mine pit water. In the past, parks lacked a unified basis for water system planning, and reviews were conducted with each party speaking for itself; now that a national standard is available, both plan preparation and review have a reference. For industrial parks, this is both a lever for saving energy and reducing costs and a pathway for responding to water use quota constraints.
The weight of the four words "strategic second water source"
One statement in the official wording deserves to be highlighted separately: promoting the transformation of unconventional water from a "supplementary water source" to a "strategic second water source." The weight of the two terms is different — a supplementary water source is used only when there is a shortage, whereas a second water source must be factored into allocation.
Behind this is an institutional chain that has already been connected: the Water Conservation Regulations set requirements for unconventional water utilization, the Ecological Environment Code explicitly incorporates unconventional water into the unified allocation of water resources, and the draft amendment to the Water Law emphasizes the "four determinations based on water" principle. What the national standard fills in is the link of "how to prepare the plan," translating the principles of higher-level laws into operable technical pathways.
But the boundaries must also be made clear: this is a recommended national standard (GB/T), which provides a technical framework and does not replace project-specific justification; whether and at what level local authorities prepare plans is still determined by local competent departments. Standards do not apply retroactively; completed plans can be self-checked against them, and the earlier the alignment, the lower the cost of subsequent adjustments.
Three hurdles remain before implementation
- Project hurdle — without specific engineering projects to connect with, even the best allocation plan remains on paper.
- Investment hurdle — pipelines, treatment facilities, and user connections all require funding, and most projects need government guidance plus market-based operation.
- Assessment hurdle — only by incorporating unconventional water utilization volume into the assessment of the strictest water resources management system and water conservation evaluation can the plan be binding.
There is another often-overlooked hurdle: user connection. Building treatment facilities is only the first step; whether pipelines can reach users' doorsteps directly determines whether the water volume can truly be used. Many projects "produce it, cannot deliver it, and cannot use it," and the problem lies precisely in this segment.
Three opportunities for water treatment enterprises
When the standard is implemented, what changes first is the planning text, and only afterward come engineering orders. For water treatment enterprises, the opportunities fall roughly into three layers:
- Planning consulting and scheme design — the two accounts of demand and supply require modeling tools; whoever can clearly calculate "different water sources for different sectors" can enter the early stage.
- Park-quality-tiered water supply and pipeline network optimization — after industrial parks prepare plans separately, tiered water supply networks, intake points, and storage facilities will form a clear engineering list.
- Metering, monitoring, and dispatching on the operation side — the prerequisite for unified allocation is unified metering; water volume, water quality, and pressure data must be able to support allocation and assessment.
TIANYI TECH's judgment is: the real threshold of this standard is not "whether engineering can be done," but "whether the two accounts in the plan can be turned into a system that is calculable, adjustable, and verifiable in operation." From planning to operation, what lies in between is precisely data and control.
TIANYI TECH (TIANYI LIMITED) focuses on AI governance for industrial water treatment, water resource reuse optimization, and digital twin technologies, providing products such as industrial wastewater treatment AI agents, industrial water reuse optimization systems, and water system digital twin platforms. For unconventional water planning and park-quality-tiered water supply scenarios, the company can provide integrated solutions for water source–user matching analysis, pipeline network dispatching optimization, and online verification of water volume and quality, helping industrial parks implement "unified allocation" down to every stream of water and every intake point.
Source: public information on the national standard Code for Preparation of Plans for Development and Utilization of Unconventional Water (GB/T 47418—2026), content published by the National Water Conservation Office (2026-06-17), and standard information from the China Standards Online Service Network. Standard clauses are subject to the official text.
Industry News
2026-11-03