[Mainland China] BGT won the bid for China's largest desulfurization wastewater zero liquid discharge salt separation project: 330 m³/h, with all sodium chloride reused in chlor-alkali production

Industry News
2026-11-03
Beijing Economic-Technological Development Area 2026 年 10 月 14 日 disclosed that BGT won the bid for Phase I of the Desulfurization Wastewater Zero Liquid Discharge Treatment System of Liaocheng Xinyuan Group (Xinfa Group), with a desulfurization wastewater treatment capacity of 330 cubic meters per hour, making it the largest desulfurization wastewater zero liquid discharge salt separation project in China to date. The project adopts the "pretreatment—membrane concentration—salt separation crystallization" route, and the produced sodium chloride is fully reused in Xinfa Group's chlor-alkali production line.

What scale is 330 m³/h

At 330 cubic meters per hour, estimated based on 8000 小时 annual operation, the annual treatment capacity is approximately 264 万 cubic meters. Previous desulfurization wastewater zero liquid discharge projects in China mostly had a single-train scale of tens to just over one hundred cubic meters per hour; 330 m³/h has raised the industry ceiling by a notch.

It should be noted that this is treatment volume, not produced water volume. Desulfurization wastewater has high salinity; after concentration, most of the water is recovered, and a small amount of concentrated water enters evaporative crystallization and is ultimately produced as solid salt. The larger the scale, the less room for error in the upstream pretreatment and membrane concentration—any fluctuation in one stage will be amplified by the downstream crystallization system.

Why desulfurization wastewater is difficult

Wastewater generated by wet flue gas desulfurization in coal-fired units is one of the "hardest nuts to crack" in industrial wastewater. Its difficulties are concentrated in three areas:

  • High salinity—high concentrations of sodium chloride, sodium sulfate, and calcium, magnesium, and heavy metal ions; direct discharge would cause soil salinization and increased water mineralization.
  • Large water quality fluctuations—water volume and quality are unstable, varying with coal type, unit load, desulfurization process, and absorber operating conditions.
  • Prone to scaling, corrosion, and foaming—calcium and magnesium readily deposit on membrane surfaces and in pipes under high-salinity conditions, while heavy metals bring risks of corrosion and catalyst poisoning.

These three characteristics determine that desulfurization wastewater zero liquid discharge cannot be solved by simply "installing a membrane set"; rather, pretreatment, concentration, salt separation, and crystallization must be designed as one system.

Three-stage process: each stage "reduces the load" for the next

The project adopts BGT's self-developed integrated zero liquid discharge salt separation process for high-salinity wastewater, and the route can be divided into three stages:

  • Pretreatment softening and impurity removal—a combination of high-efficiency sedimentation + filtration removes suspended solids, calcium and magnesium hardness, and heavy metal ions, safeguarding the stable operation of the subsequent membrane system.
  • Membrane deep concentration—multistage concentration by ultrafiltration + reverse osmosis + electro-driven membrane reduces the wastewater to the minimum volume, greatly lowering the investment and operating costs of evaporative crystallization.
  • Qualitative salt crystallization—freezing/nanofiltration coupled salt separation technology + MVR evaporative crystallization achieves efficient separation of sodium chloride and sodium sulfate, producing high-quality salt products that meet industrial salt standards.

The essence of this route lies in the two words "reducing the load": if pretreatment is unstable, the membranes will foul; if concentration is insufficient, the scale and energy consumption of evaporative crystallization cannot be reduced; if salt separation is not pure, the salt cannot be sold or used. The three stages are connected in series, and any corner-cutting in one stage will be exposed as cost in the final stage.

The real breakthrough: full reuse of sodium chloride in chlor-alkali

The largest cost item of a zero liquid discharge project is often not electricity, nor membranes, but mixed salt disposal. If salt separation is incomplete, the output is mixed salt, which can only be disposed of as hazardous waste or general solid waste, a net expenditure per ton. Many zero liquid discharge projects "work technically but not economically", and this is the link where they get stuck.

This project brings the quality of sodium chloride up to the raw material requirements of the chlor-alkali industry, and all of it is reused in Xinfa Group's chlor-alkali production line, forming a closed loop of "power plant desulfurization—wastewater treatment—salt resource utilization—chlor-alkali production". The significance of this step is turning "hazardous waste" into "raw material": salt that originally required paid disposal has now become an input for downstream production, and zero liquid discharge has changed from a pure cost center into a link in the circular economy.

However, "full reuse" places extremely high demands on salt separation purity, and it is not a one-time compliance but long-term stable compliance. Chlor-alkali electrolysis is extremely sensitive to impurities; trace amounts of calcium, magnesium, heavy metals, or organic matter can cause damage to the ion membrane. This means that operational control must be an order of magnitude more refined than "compliance discharge".

APS integration: the water system must "understand" the language of the unit

The project has a requirement that is easily overlooked but has great impact on the industry: the entire desulfurization wastewater zero liquid discharge system must meet the functional requirements of the unit's Automatic Plant Startup and Shutdown System (APS), and all process, electrical, and control components must be seamlessly integrated into the APS system to achieve automated interlocking throughout the unit startup and shutdown process.

This means the water treatment system is no longer an independent "workshop" within the plant, but part of the unit. Unit start-up/shutdown, load ramping, and emergency conditions are all transmitted to the water system through the APS; the water system's start-up/shutdown sequence, interlock conditions, and fault responses must also comply with the unit's overall logic. The requirements for control logic, equipment reliability, and response speed far exceed those of conventional wastewater treatment projects.

This is also where AI optimization truly adds value: not "watching" the water system from the outside and tuning parameters, but embedding into the DCS/APS control chain to perform prediction and optimization within safety boundaries. The more centralized the control authority, the harder the boundary constraints on the optimization algorithm, and the clearer what can actually be done.

Hidden thresholds of retrofitting existing equipment

The project also involves extensive retrofit and upgrade of existing equipment, requiring compatibility between old and new equipment and between old and new control systems without affecting the normal operation of the power plant. The difficulty of such work often lies not in how advanced the new installations are, but in "how to connect the old system."

The communication protocols, instrument accuracy, valve response, and piping materials of old equipment may all be standards from decades ago; for the new system to coexist with them, extensive interface adaptation and fallback plans are required. Many projects experience repeated shutdowns during the commissioning phase, and the problems all originate here. Companies that can do this part well rely not on single-point technology, but on long-term accumulated engineering experience.

Three variables of the zero liquid discharge business model

Abstracting this type of project, the economics depend on three mutually constraining variables:

  • Salt separation purity — determines whether the salt can be reused or sold externally, directly changing the revenue structure.
  • Concentration factor — determines the liquid volume entering evaporative crystallization, directly affecting investment and energy consumption.
  • Operational stability — determines the number of unplanned shutdowns, and each shutdown is a double loss for the power plant (water system + unit).

The three cannot be optimized independently: increasing the salt washing step to improve purity will reduce recovery; approaching the saturation point to increase the concentration factor will increase scaling risk; lowering load for stability will sacrifice treatment capacity. True optimization is system-level and requires the combined support of models, data, and process experience.

TIANYI TECH's view is: zero liquid discharge of desulfurization wastewater has moved from the "demonstration project" stage to the "scaled replication" stage, and the next competition is not about "whether it can be done," but about "whether it can save costs stably over the long term." And the words "long-term stability" must ultimately land on online monitoring, predictive maintenance, and closed-loop control.


TIANYI TECH (TIANYI LIMITED) focuses on AI governance for industrial water treatment, water resource reuse optimization, and digital twin technology, providing products such as industrial wastewater treatment AI agents, industrial water reuse optimization systems, and water system digital twin platforms. For high-salinity wastewater zero liquid discharge and salt separation crystallization scenarios, the company can provide membrane system fouling early warning, concentration factor optimization, crystallization feed balancing, and equipment health management solutions, helping projects turn "meeting standards once" into "stable for ten years."

Source: Beijing Economic-Technological Development Area official website (2026-10-14), China Water Network (h2o-china.com) project reports. Treatment scale, process route, and reuse method are subject to public information from the enterprise and the owner.

Copyright © 2026 TIANYI LIMITED All Rights Reserved