Yiwu Water Treatment Co., Ltd. 11月10日 Announcement: China Construction Third Engineering Bureau Group Co., Ltd. has won the bid for the Shuangjianghu Water Purification Plant Phase II Project — Water Purification Plant Project 2 Section at 12.3545亿 yuan, with a design capacity of 36万 cubic meters/day and a construction period of 1860日 calendar days. The main treatment process is "AAO + High-efficiency Sedimentation Tank + Deep Bed Filter + Ozonation", and the effluent shall meet the Grade A standard and Zhejiang provincial local standards, with some indicators controlled according to Surface Water Class III quasi-standard. Upon completion, it will be merged with Phase I's 16万 cubic meters/day, forming the 52万 cubic meters/day largest single node in the city.
12.35亿 yuan and 36万 cubic meters/day — this is one of the largest single wastewater treatment plant construction sections in China this year. But to truly understand this project, what matters is not the amount of money, but a few easily overlooked lines in the tender scope — "retrofit of Phase I biological odor removal system", "retrofit of Phase I central control room and smart system", "retrofit of Phase I pretreatment workshop and overflow pump station", "retrofit of Phase I inlet well".
These four lines indicate that the Phase II 2 section is not merely building a new plant next to Phase I. It requires deep coupling with Phase I in both physical space and control systems, while Phase I must maintain normal operation during construction.
The foundation left by Phase I: the first fully underground plant in central Zhejiang
Shuangjianghu Water Purification Plant Phase I has a capacity of 16万 cubic meters/day and was commissioned in 2023年. It is the first fully underground wastewater treatment plant in central Zhejiang and has been included in the list of "New (Retrofit) Construction Projects Benchmarking Green and Low-carbon Wastewater Treatment Plants" by the National Development and Reform Commission and the Ministry of Housing and Urban-Rural Development. Its energy configuration has been repeatedly cited in the industry: the entire plant area is covered with photovoltaics, generating nearly 1000万 kWh annually, equipped with 1900 kW/4085 kWh chemical energy storage (combined with Houzhai and Dachen plants totaling 2664 kW/5662 kWh, reducing carbon emissions by 2067 tons annually through "peak shaving replacing coal"), supplemented by water-source heat pumps, precise aeration and precise chemical dosing, achieving a total carbon emission reduction rate of 28.5%.
The technical significance of being fully underground lies in "hiding the NIMBY facility": parks and sports facilities can be built on top of the tank structure. In the scope of this 2 section, terms such as "Ice and Snow Center", "Multifunctional Hall", "Corridor" and "Outdoor Landscape" appear, which precisely demonstrates that the roof of this plant is urban public space, with the wastewater treatment plant and citizens' lives vertically stacked together. This also explains why the odor removal system is included in the section — with people active on the roof, odor control is not an environmental indicator but a basic condition of use.
Class III quasi-standard "some indicators": a cost switch on paper
The tender documents stipulate for effluent: meeting the Grade A standard of the "Discharge Standard of Pollutants for Municipal Wastewater Treatment Plants" (GB 18918—2002) and Zhejiang provincial local standards, while some indicators shall also be controlled according to the Class III quasi-standard of the "Environmental Quality Standards for Surface Water".
The weight of this half sentence can only be seen clearly through numerical comparison. Grade A requirements for Chemical Oxygen Demand, ammonia nitrogen and Total Phosphorus are 50, 5 (8), 0.5 mg/L respectively; Surface Water Class III standards are 20, 1.0, 0.2 mg/L. Even if only "some indicators" approach the Class III quasi-standard, it means that conventional secondary biological treatment alone can no longer meet the standards, and advanced treatment units must be added.
This is precisely why Ozonation appears in the process route, and the logic behind the combination of "AAO + High-efficiency Sedimentation Tank + Deep Bed Filter + Ozonation": AAO handles the main functions of Denitrification and phosphorus removal, the high-efficiency sedimentation tank further removes phosphorus and reduces Suspended Solids, the deep bed filter polishes particulate matter and some organic matter, and Ozonation is responsible for the removal of refractory organic matter and color. With four stages in series, any efficiency decline in any stage will be transmitted to the effluent.
However, advanced treatment is energy-intensive. The power consumption of ozone generators, backwash pumps of deep bed filters, and chemical dosing systems of high-efficiency sedimentation tanks will all push up the electricity consumption per ton of water. This leads to a conclusion that must be faced squarely: a 36万 cubic meters/day wastewater treatment plant implementing Class III quasi-standard for some indicators has a "baseline" electricity consumption per ton of water that is inherently higher than a plant implementing Grade A. High standards are not free — they will push wastewater treatment from "paying for compliance" to "paying by water quality", and turn energy saving and consumption reduction from a slogan into a cost item.
52万 cubic meters/day: the largest node in one network
All 8 wastewater treatment plants in Yiwu have achieved cross-basin scheduling, with a scheduling capacity of 28万 cubic meters/day at any given time. Shuangjianghu Phase I's 16万 plus Phase II's 36万, after merging, will reach 52万 cubic meters/day, becoming the largest single node in this "one network".
This is the real meaning of the phrase "renovating the Phase I central control room and smart system": the completed central control system must dispatch both Phase I and Phase II simultaneously—one system managing two plants. For a city that has already achieved city-wide cross-plant dispatch, this means the complexity of the dispatch algorithm rises by an order of magnitude—the water quality, water volume, energy consumption, and chemical consumption of different plants must be optimized under the same objective function, rather than each simply meeting its own standards.
From an engineering perspective, there are three layers of difficulty here:
- Renovation without shutdown—Phase I is already in operation. During the renovation of its influent pumping station, pretreatment workshop, and odor control system, the treatment capacity of 16万 m³/day must not be interrupted, requiring phased switching, temporary bypass, and dual-line parallel operation;
- Unified control authority—although both phases use AAO processes, the equipment brands, instrument protocols, and control logic may not be consistent, so the central control system must achieve protocol compatibility and data alignment;
- Multiple dispatch objectives—a city-wide network must balance water volume balance, energy cost, effluent quality, and carbon emission reduction. After Phase II is commissioned, the dispatch space becomes larger, and the optimization benefits also become larger.
Also noteworthy is the construction period: 1860日 calendar days, approximately 5年1 months. This is not the conventional construction pace of 2–3年 for a wastewater treatment plant; it reflects the superimposed difficulty of the 36万 m³/day box-type engineering plus fully buried structure plus Phase I renovation without shutdown. For bidding enterprises, the 5年 construction period means long-cycle locking of labor, machinery, and materials, and also means that project team stability determines success or failure more than the bid price.
Three Lessons from Fully Buried Plants
This Yiwu project leaves the industry three reusable lessons.
First, the decision logic for full burial is land, not technology. In a high-density commercial city like Yiwu, the opportunity cost of above-ground space is far higher than the incremental cost of an underground box structure. Making the plant roof into an ice and snow center, multifunctional hall, and park is equivalent to exchanging one wastewater treatment plant for a piece of urban public space—this account can only be balanced in cities where land is scarce.
Second, energy self-sufficiency must be a design input, not a later retrofit. The prerequisite for Phase I to achieve a carbon emission reduction rate of 28.5% is that space and interfaces for photovoltaics, energy storage, and water-source heat pumps were reserved in the design. By Phase II, if energy units are not included at the scheme stage, the cost and effectiveness of later retrofits will be discounted.
Third, stock renovation must be written into the new construction lot. Including "renovating the Phase I central control room" in the Phase II construction scope is the most worth-learning arrangement in this tender—it avoids the interface disputes caused by "new construction belongs to new construction, renovation is tendered separately," and also enables the new and old systems to be designed according to the same set of standards from the outset.
For TIANYI TECH, the value of such super-large plant stations lies not in scale itself, but in the fact that it binds wastewater treatment, reclaimed water, and energy management into one assessment framework. As effluent standards move toward quasi-Class III and energy consumption becomes the main cost line, the marginal cost of reclaimed water reuse is instead declining—because the advanced treatment unit has already prepared the water quality basis for reclaimed water. This is also the practical basis for our judgment that "a high-standard wastewater treatment plant is naturally a reclaimed water plant."
Sources: Yiwu Water Treatment Co., Ltd. bid result announcement (2026年11月10日, as reported by BJX Environmental Protection Network, including lot scope and Phase I operating data), the list of "benchmark wastewater treatment plants for green and low-carbon development" by the National Development and Reform Commission and the Ministry of Housing and Urban-Rural Development, GB 18918—2002 "Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant," and "Environmental Quality Standards for Surface Water" (GB 3838—2002). This article was compiled by TIANYI TECH industry research and is for reference only.
Industry News
2026-11-13