News
News
News

[Mainland China] China Railway 17th Bureau Consortium Wins Wuxi Meicun Industrial Water Treatment Plant with a Bid of RMB 156 Million: 30,000 m³/day of Pure Industrial Wastewater, Effluent Meeting Class III Standard, Equipped with a Reclaimed Water Pumpin

Industry News
2026-11-14
BJX Environmental Protection Network11月2日discloses: the consortium of China Railway 17th Bureau Group Co., Ltd., Shanghai Urban Construction Water Engineering Co., Ltd., and China Railway 17th Bureau Group Municipal Construction Co., Ltd. won the bid for the construction general contracting of the Wuxi Meicun Industrial Water Treatment Plant construction project, with a winning bid amount of 1.5619亿 yuan and a construction period of 500日 calendar days. The total project investment is approximately 2.68亿 yuan, with a design capacity of 3万 cubic meters/day, specifically treating industrial wastewater discharged by enterprises. The main effluent indicators reach Surface Water Standard Class III, and a reclaimed water pump station of the same scale of 3万 cubic meters/day is built as supporting facility.

In the past two years, bid announcements for wastewater treatment plants have emerged endlessly, but it is rare to see the trio of "pure industrial wastewater + Class III effluent + same-scale reclaimed water pump station" appear simultaneously in one bid section. The real highlight of the Meicun project is not the amount of 1.56亿 yuan, but that it directly writes the design endpoint of an industrial wastewater treatment plant as "Reclaimed Water Reuse"—the produced water is equipped with pumps and pipes according to reuse standards, rather than being discharged according to emission standards.

Why should an industrial wastewater plant be designed to Class III standards

The Meicun project serves industrial enterprises in Wuxi. Wuxi is a major advanced manufacturing hub in the Yangtze River Delta, with clusters of electronic information, high-end equipment, and new energy industries. Its industrial wastewater has complex composition and large water quality fluctuations. The project adopts a combined route of "pretreatment + secondary biochemical treatment + advanced treatment". The structures include a pretreatment combined tank, a biochemical and auxiliary facilities combined tank, an advanced treatment combined tank, an initial rainwater tank, a sludge dewatering room (renovation of the existing MBR workshop), etc., with a total construction area of approximately 4585 square meters; after completion, the annual industrial wastewater treatment volume will be 1095万 tons, with no hazardous waste generated.

What does Class III effluent mean? The limits of COD, ammonia nitrogen, and total phosphorus for the Grade A emission standard are 50, 5 (8), and 0.5 mg/L respectively, while Class III surface water corresponds to approximately 20, 1.0, and 0.2 mg/L—the gap must be bridged by advanced treatment, and secondary biochemical treatment alone cannot achieve it. For ordinary discharge plants, this process is an "extra cost"; but for an industrial water plant targeting reuse, Class III effluent is the raw water for reclaimed water, and subsequent delivery to users through the reclaimed water pump station only requires fine treatment according to the purpose. The cost of advanced treatment here is not a cost, but part of product pricing.

What does it mean that the reclaimed water pump station is of the same scale as the wastewater plant

The most telling configuration of the project is that the reclaimed water pump station and the wastewater treatment scale are both 3万 cubic meters/day. This is equivalent to determining at the project approval stage that: in principle, all water produced by this plant has the conditions for reuse delivery. In the past, reclaimed water facilities in most wastewater treatment plants were "looking for users after construction", and the pump station scale was configured at a discount based on the existing user volume; Meicun builds reuse facilities at full scale, indicating that the local government locked in the water demand of industrial users at the planning stage—the water intake pressure of Wuxi's high-water-consumption manufacturing industry is exactly offset by the reclaimed water from this plant.

This is consistent with the direction of several cases we have observed recently: Xun County in Henan wrote a 6万 cubic meters/day reclaimed water plant into the urban-rural integrated water supply and drainage EPC package, and Yiwu in Zhejiang bundled the renovation of the Phase I central control room with Phase II construction in the Shuangjianghu Phase II project. The common trend is that reclaimed water facilities have changed from "optional supporting facilities" to "mandatory construction units", and the reuse scale is written into the design documents at the project approval stage. The new Water Law passed by vote of 11月6日 further clarifies at the legal level that "water for urban greening, road cleaning, etc. should give priority to reclaimed water", and the system and engineering are converging in the same direction.

The "Wuxi Model" of centralized industrial wastewater treatment

The Meicun project also has an easily overlooked industry implication: separate treatment of industrial wastewater and domestic sewage. The project is "specifically used to treat industrial wastewater discharged by enterprises" rather than receiving mixed municipal sewage. This is the same approach as Jinjiang in Fujian—the newly built Dongshi plant in Jinjiang only receives domestic sewage, while industrial wastewater is separately treated in a centralized manner. Industrial powerhouse cities are stripping industrial wastewater from the municipal pipe network and treating and reusing it centrally according to industry characteristics. The benefits are obvious:

  • Controllable Water Quality — The water quality boundaries of a single type of wastewater are clearly defined, allowing process design as well as chemical and power consumption to be precisely determined, avoiding the operating conditions where high-concentration industrial wastewater shocks municipal plants;
  • Matched Reuse — Industrial users are located nearby, reclaimed water transmission distances are short, and water quality requirements are clear. "Water produced is water used," making the commercial loop easiest to close;
  • Clear Responsibilities — Enterprise discharge is connected according to dedicated standards, and the boundary between pretreatment responsibility and centralized treatment responsibility is stipulated through dedicated contracts, reducing mixed-discharge disputes.

For equipment and engineering companies, such projects correspond to a clear procurement list: beyond conventional equipment such as bar screens, blowers, pumps, and mixers, the main incremental demand lies in the advanced treatment stage — high-efficiency sedimentation, deep-bed filters, Ozonation units, and supporting automation systems. "Industrial Wastewater Quasi-Class III" is becoming the mainstream design benchmark for new projects in eastern industrial parks; equipment combinations aligned with this benchmark in advance will have a first-mover advantage in the next batch of tenders.

TIANYI TECH has long served Industrial Park wastewater treatment and Reclaimed Water Reuse projects, covering the full chain from segregated pretreatment and advanced treatment to reuse transmission and distribution. Our experience is that the key to success or failure of industrial wastewater reuse projects often lies not in the main process package, but in locking down the influent water quality boundaries — the volatility of enterprise discharge must be quantitatively constrained in the connection agreement; otherwise, stable compliance of the advanced treatment stage is castles in the air. The Meicun project's approach of configuring the reclaimed water pump station at full scale also reminds us that when designing reuse solutions for customers, "long-term users" should be incorporated into the planning scope of the pipeline network and pump stations in advance, avoiding reconstruction immediately after completion.


Source: BJX Environmental Protection Network "1.56亿! Jiangsu Wuxi Meicun Industrial Water Treatment Plant Construction Project General Contracting Bid Winner" (2026年11月2日), Kelier Technology Industry News (2026年11月). This article is compiled by TIANYI TECH Industry Research for reference only.

Copyright © 2026 TIANYI LIMITED All Rights Reserved