Defluoridation: calcium salt treatment bottoms out at 15–30; achieving the standards of 8 and 2 requires a different mechanism.
Fluoride-Containing
Defluoridation: calcium salt treatment bottoms out at 15–30; achieving the standards of 8 and 2 requires a different mechanism.
Multi-industry projects across China (photovoltaics and semiconductors, display
Pilot to full-scale engineering (3,800 to 45,000 m³/d; influent fluoride 4 to 93
The same "fluoride" has five sets of limits in discharge standards, only one form in solution that can precipitate, and a portion in the laboratory that cannot be measured. This article examines four aspects of the issue: why primary calcium salt precipit
View Details
Total Phosphorus: only one type of phosphorus can settle; the other two must first undergo valence change.
Phosphorus-containin
Total Phosphorus: only one type of phosphorus can settle; the other two must first undergo valence change.
Across multiple industries nationwide (electroplating and electroless nickel pla
Pilot to full-scale engineering (from 1 L beaker bench test to 500 t/d; influent
In the influent of electroless nickel plating rinse water, Total Phosphorus (TP) is 1200 mg/L. Fenton Oxidation combined with coagulation reduces it to 15 mg/L, a removal rate of 98.75%, yet it still exceeds the standard by 15 times. What remains is not i
View Details
Total Nitrogen: compliant ammonia nitrogen accounts for only one-third of the limit, with the remainder relying on a ratio.
Biological Denitrifi
Total Nitrogen: compliant ammonia nitrogen accounts for only one-third of the limit, with the remainder relying on a ratio.
Across multiple industries nationwide (municipal wastewater treatment, petrochem
Pilot to full-scale (6,000 to 60,000 m³/d; influent Total Kjeldahl Nitrogen 35 t
The effluent ammonia nitrogen is 5 mg/L, and the ammonia nitrogen allowance of Grade A is just used up, yet it accounts for only one-third of the Total Nitrogen limit of 15. The remaining ten points are almost entirely nitrate nitrogen. This paper examine
View Details
Sulfur and cyanide: the same batch of sodium hypochlorite can detoxify both, but not in the same tank.
Treatment of Cyanide
Sulfur and cyanide: the same batch of sodium hypochlorite can detoxify both, but not in the same tank.
Across multiple industries nationwide (electroplating and surface treatment, gol
Pilot to full-scale engineering (30 to 20,000 m³/d; influent total cyanide 80 to
Sulfide 1.0 and Total Cyanide 0.5 look like the same type of parameter, but they are actually two different numbers: an odor threshold and a toxicological threshold. One requires 2.7 mg chlorine per 1 mg, the other requires 2.2 to 8.8 mg chlorine per 1 mg
View Details
Coal chemical wastewater: this industry cannot be found in the standards, and there is no salt discharge outlet either.
Coal chemical plant-
Coal chemical wastewater: this industry cannot be found in the standards, and there is no salt discharge outlet either.
Multi-industry projects across China (modern coal chemical, coal-to-olefins, coa
Pilot to full-scale engineering (120 m³/h to tens of thousands of m³/d; phenol-a
The current GB 31571 defines the petrochemical industry as using petroleum fractions and natural gas as raw materials, and coal-to-olefins is not included. It was only in the second draft for comments in May 2026 that coal-to-olefins was written into the
View Details
Moving Bed Biofilm: a 60% fill ratio occupies only 6% of the tank volume; the two-thirds line governs the power.
Moving Bed Biofilm R
Moving Bed Biofilm: a 60% fill ratio occupies only 6% of the tank volume; the two-thirds line governs the power.
Across multiple industries nationwide (petroleum refining, petrochemical, coal c
Pilot to Engineering Scale (Pilot 0.12 to 24 m³/d; Engineering 5,000 m³/d to 300
Clause 7.8.28 of GB 50014—2021 requires MBBR to be designed based on surface loading, with the unit g/(m²·d). However, the tender documents specify filling ratio, the product brochures specify g/(m³ media·d), the reports specify kg/(m³ tank volume·d), and