Cases

Cases

Cases
Filter bed: 5–8 m/h is not a selected value; it is achieved by removing that 20 mg from the influent.
Granular Media Filtr
Filter bed: 5–8 m/h is not a selected value; it is achieved by removing that 20 mg from the influent.
Nationwide multi-industry applications (centralized wastewater treatment plants
Pilot to full-scale engineering (tens of thousands to 200,000 m³/d; filtration r
For the same V-type filter, the standard for the water supply side specifies 8–10 m/h, while the drainage side specifies only 5–8. The difference is not a matter of conservatism but of the suspended solids in the influent. Four sets of measured data lock
View Details
Neutralization: to adjust pH from 3 to 6.5, 28 grams of lime is required based on pH calculation, while 840 grams is required based on acidity calculation.
Neutralization and p
Neutralization: to adjust pH from 3 to 6.5, 28 grams of lime is required based on pH calculation, while 840 grams is required based on acidity calculation.
Multi-industry nationwide (electroplating and surface treatment, acidic water fr
Pilot to full-scale engineering (tens to tens of thousands of m³/d; influent pH
pH is intensity, not capacity. Water at pH 3 in the same tank could be 1 milliequivalent of hydrochloric acid or 57 milliequivalents of acetic acid. Calculating neutralization demand by pH can be off by a factor of 30, and for acid mine water by a factor
View Details
Injection water quality: permeability is magnified 150 times, while the median particle size is magnified only 5 times, so the high-permeability zone is actually subject to stricter requirements.
Produced Water Reinj
Injection water quality: permeability is magnified 150 times, while the median particle size is magnified only 5 times, so the high-permeability zone is actually subject to stricter requirements.
Nationwide multiple oilfields (waterflood development of clastic rock reservoirs
Pilot to engineering scale (single station from hundreds to tens of thousands of
In the five-tier limits of SY/T 5329—2012, permeability spans a 150-fold range, while suspended solids are relaxed only 30-fold, oil content 10-fold, and median particle size 5-fold. Dividing the limits by the pore-throat diameter back-calculated from per
View Details
Thallium-containing wastewater: for the same 0.0173, it is 1.8% below the 0.017 limit and thus compliant, but 2.46 times above the 0.005 limit.
Thallium-containing
Thallium-containing wastewater: for the same 0.0173, it is 1.8% below the 0.017 limit and thus compliant, but 2.46 times above the 0.005 limit.
Multi-industry nationwide (lead-zinc mining and smelting, tin-antimony-mercury,
Pilot to full-scale engineering (influent 0.6 μg/L to 5 mg/L; effluent 5 μg/L to
The amendment to GB 25466 sets Total Thallium at 0.017 (0.005) mg/L, and the figure in parentheses applies only to separate discharge from the mining and ore-dressing units. In a 2025 case, the measured value of 0.0173 fell exactly between the two numbers
View Details
Hardness: for the same 0.03 mmol/L, the general national standard calculates 1.5 mg/L, while the instrument conversion table calculates 3 mg/L.
Hardness Basis and S
Hardness: for the same 0.03 mmol/L, the general national standard calculates 1.5 mg/L, while the instrument conversion table calculates 3 mg/L.
Multi-industry nationwide coverage (boiler make-up water, circulating cooling wa
Pilot to municipal scale (5,000 to 30,000 m³/d groundwater plants; industrial so
Article 1 of the General Provisions of GB/T 1576—2018 specifies that hardness is based on monovalent ions as the elementary unit, so 1 mmol/L equals 50.04 mg/L as calcium carbonate; whereas the conversion commonly used in instrument manuals and European l
View Details
Drainage metering: a Class 0.5 meter operating at 10% of its range effectively becomes Class 5; a 12 mm water level difference passes acceptance, yet the flow differs by 19.5%.
Drainage Metering an
Drainage metering: a Class 0.5 meter operating at 10% of its range effectively becomes Class 5; a 12 mm water level difference passes acceptance, yet the flow differs by 19.5%.
Nationwide multi-industry coverage (industrial park wastewater treatment plants,
Pilot to engineering scale (tens to tens of thousands of m³/d; single meter DN50
HJ 354 specifies two limits for open channel flow meters: a liquid level comparison error of 12 mm and a flow comparison error of ±10%. Substituting 12 mm into the 1.569-power relationship between Q and h, at a water level of 100 mm the flow difference is
View Details
Copyright © 2026 TIANYI LIMITED All Rights Reserved